Search results for "surface properties"
showing 10 items of 421 documents
Abundance and Distribution Patterns of Thunnus albacares in Isla del Coco National Park through Predictive Habitat Suitability Models
2016
Information on the distribution and habitat preferences of ecologically and commercially important species is essential for their management and protection. This is especially important as climate change, pollution, and overfishing change the structure and functioning of pelagic ecosystems. In this study, we used Bayesian hierarchical spatial-temporal models to map the Essential Fish Habitats of the Yellowfin tuna (Thunnus albacares) in the waters around Isla del Coco National Park, Pacific Costa Rica, based on independent underwater observations from 1993 to 2013. We assessed if observed changes in the distribution and abundance of this species are related with habitat characteristics, fis…
Quantum effects in the capture of charged particles by dipolar polarizable symmetric top molecules. II. Interplay between electrostatic and gyroscopi…
2013
ally nonadiabatic channel treatment of the capture of charged particles by dipolar polarizable symmetric top molecules with the aim to reveal quantum effects in the collision dynamics. In general, these effects are related to the discrete nature of the intrinsic, orbital, and total angular momenta, to the quantum character of passage of collision partners across effective potential barriers and drops, and to the interplay of two types of anisotropic interactions, the gyroscopic (Coriolis) and the electrostatic ones. The latter feature, in principle, leads to a coupling of capture channels. In the calculation of capture cross sections or rate coefficients, however, this coupling can be ignor…
Effect of saliva contamination on bracket failure with a self-etching primer: A prospective controlled clinical trial
2010
Introduction The aim of this study was to evaluate in vivo the effect of saliva contamination at different stages of the bonding procedure on the bond failure rate and the adhesive remaining on teeth after debonding brackets bonded with a hydrophilic self-etching primer (Transbond Plus self-etching primer [TSEP], 3M Unitek, Monrovia, Calif). Methods This was a prospective controlled clinical trial. The sample consisted of 46 patients with similar treatment plans and mechanotherapies. Stainless steel brackets (n = 531) were bonded with TSEP. The patients were divided into 2 groups: contamination with saliva before TSEP application and contamination with saliva after TSEP application. In both…
Amphiphilic Dendrimers Control Protein Binding and Corona Formation on Liposome Nanocarriers
2020
Amphiphilic polyphenylene dendrimers (PPDs) with distinct lipophilic and positively or negatively charged surface groups were adsorbed onto liposomes and their impact on protein adsorption in blood plasma was studied. The PPD corona reduced binding of specific opsonins and increased the adsorption of proteins controlling cellular uptake based on their surface patches.
Early bone healing around implant surfaces treated with variations in the resorbable blasting media method. A study in rabbits.
2010
Objective: this study aimed to histomorphologically and histomorphometrically evaluate the in vivo response to three variations in the resorbable blasting media (RBM) surface processing in a rabbit femur model. Study Design: screw root form implants with 3.75 mm in diameter by 8 mm in length presenting four surfaces (n=8 each): alumina-blasted/acid-etched (AB/AE), bioresorbable ceramic blasted (TCP), TCP + acid etching, and AB/AE + TCP were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The implants were placed at the distal femur of 8 New Zeland rabbits, remaining for 2 weeks in vivo. After sacrifice, the implants were nondecalcified processed to 30 …
Marginal bone loss in relation to the implant neck surface: An update
2010
A review is made of the publications on the marginal bone loss of implants with a polished neck, rough neck with microthreading, and rough neck without microthreading. A PubMed search was carried out with the following key words: machined neck implant, polished neck implant, marginal bone loss, covering the period between January 1998 and March 2009. Inclusion was limited to those human clinical studies involving a minimum follow-up of 12 months, and registering the level of bone loss from the time of placement of the implant or prosthetic restoration to the end of follow-up. For most of the authors there were no significant differences in marginal bone loss between polished neck and rough …
Effects of a local single dose administration of growth hormone on the osseointegration of titanium implants.
2021
The aim of the present study was to evaluate the effect of different concentrations of growth hormone (GH) on endosteal implant?s surface at the early stages of osseointegration. Sixty tapered acid-etched titanium implants were divided into four groups: i) Collagen, used as a control group; and three experimental groups, where after collagen coating, GH was administered directly to the surface in varying concentrations: ii) 0.265 mg, iii) 0.53 mg, and iv) 1 mg. Implants were placed in an interpolated fashion in the anterior flange of C3, C4 or C5 of 15 sheep with minimum distance of 6 mm between implants. After 3-, 6- and 12-weeks of healing samples were harvested, histologically processed,…
Topographic characterisation of dental implants for commercial use.
2016
Background To characterize the surface topography of several dental implants for commercial use. Material and Methods Dental implants analyzed were Certain (Biomet 3i), Tissue Level (Straumann), Interna (BTI), MG-InHex (MozoGrau), SPI (Alphabio) and Hikelt (Bioner). Surface topography was ascertained using a confocal microscope with white light. Roughness parameters obtained were: Ra, Rq, Rv, Rp, Rt, Rsk and Rku. The results were analysed using single-factor ANOVA and Student-Neuman-Keuls(p<0.05) tests. Results Certain and Hikelt obtained the highest Ra and Rq scores, followed by Tissue Level. Interna and SPI obtained lower scores, and MG-InHex obtained the lowest score. Rv scores followed …
Impact of implant thread design on insertion torque and osseointegration:a preclinical model
2022
Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thread thickness of the implants is increased, resulting in an increased contact area in implants designed with healing chambers. The aim of this study was to evaluate the effect of two implant designs with different thread profiles on the osseointegration parameters and implant stability at 3- and 6-weeks in vivo using a well-established preclinical dog model. A total of 48 type V Ti alloy implants were divided…
A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.
2014
Abstract Statement of problem Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Purpose The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Material and methods Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Resu…