Search results for "switching"
showing 10 items of 288 documents
Improving angle stability by switching shunt reactors in mixed overhead cable lines. An Italian 400 kV case study
2019
Stringent environmental constraints make the construction of new transmission overhead lines more and more difficult. Alternatively, today it is possible to use cable lines for high (HV) and extra-high (EHV) voltage systems. The configuration of the so-called mixed lines can create some problems in the operation of the electrical system, both during steady-state and transient conditions. In particular, the system stability is one of the main concerns when analyzing the dynamic response of power systems. In this paper, the study of angular stability of a system containing a mixed line is presented: a specific control logic applied to the shunt reactors of the mixed line is proposed as improv…
Direct Instruction vs. Cooperative Learning in Physical Education: Effects on Student Learning, Behaviors, and Subjective Experience
2020
(1) Background: The objective was to analyze if cooperative learning (CL) can have benefits compared to direct instruction (DI) in learning, behavior, and subjective experience of pupils. (2) Methods: An intervention was performed with a counterbalanced within-subjects design. To perform the intervention, 75 schoolchildren aged 10 to 12 from four primary classes were divided into two groups, and two units were taught in each one, namely &ldquo
Portfolio diversification in the sovereign credit swap markets
2018
We develop models for portfolio diversification in the sovereign credit default swaps (CDS) markets and show that, despite literature findings that sovereign CDS spreads are affected by global factors, there is sufficient idiosyncratic risk to be diversified. However, we identify regime switching in the times series of CDS spreads and spread returns, and the optimal diversified strategies can be regime dependent. The developed models trade off the CVaR risk measure against expected return, consistently with the statistical properties of spreads. We consider three investment strategies suited for different CDS market participants: for investors with long positions, speculators that hold unco…
Pricing sovereign contingent convertible debt
2018
We develop a pricing model for Sovereign Contingent Convertible bonds (S-CoCo) with payment standstills triggered by a sovereign's Credit Default Swap (CDS) spread. We model CDS spread regime switching, which is prevalent during crises, as a hidden Markov process, coupled with a mean-reverting stochastic process of spread levels under fixed regimes, in order to obtain S-CoCo prices through simulation. The paper uses the pricing model in a Longstaff-Schwartz American option pricing framework to compute future state contingent S-CoCo prices for risk management. Dual trigger pricing is also discussed using the idiosyncratic CDS spread for the sovereign debt together with a broad market index. …
The influence of platform switching in dental implants. A literature review.
2010
Introduction: The platform switching concept involves the reduction of the restoration abutment diameter with respect to the diameter of the dental implant. In 1991, dental implants of 5 and 6 mm diameter platforms were introduced. However, matching-diameter prosthetic abutments were not available. These implants were restored with “standard”-diameter prosthetic components (4,1 mm). Long-term follow up around these wide-platforms showed higher levels of bone preservation. In time, it has been called platform switching. The first case report applying this concept was indexed in MedLine in 2005. Materials and Methods: The aim of this article is to carry out a literature review of articles whi…
The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study
2011
Objective: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis.Study Design: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coron…
On-line trace enrichment for the determination of ethacrynic acid in urine by liquid chromatography and column-switching
1993
Abstract A chromatographic method based on liquid chromatography (LC) using column-switching for the determination of ethacrynic acid in urine samples, is described. The proposed system uses a Hypersil ODS-C18, 30 μm (20 mm × 2.1 mm i.d.) pre-column for the pre-concentration and separation of ethacrynic acid from the biological matrix. Polar urinary compounds are removed by flushing the pre-column with purified water, and the enriched analyte is then switched in back-flush mode onto an HP-LiChrospher RP C18, 5 μm (125 × 4 mm i.d.) analytical column, where it is chromatographed using an acetonitrile-acetate buffer gradient elution. The UV detector was set at 275 nm. The recovery of drug was …
Single-frequency active Q-switched Distributed Fiber Laser Using Acoustic Waves
2007
This letter presents a single mode, actively Q-switched distributed feedback fiber laser. Acoustic pulses are launched into an erbium-doped fiber Bragg grating, resulting in the introduction of a traveling defect. Thus, a transmission peak appears in the reflection band while the pulse travels along the grating. This effect allows the laser to operate in a Q-switched regime, providing optical pulses which repetition rate was continuously tuned up to 10 kHz. Pulses of 168 mW of peak power and 73 ns of temporal width were obtained at low repetition rate.
Dual-kind Q-switching of erbium fiber laser
2014
Two different regimes of Q-switching in the same implementation of an actively Q-switched erbium-doped fiber laser are demonstrated. Depending on the active fiber length and repetition rate of an intracavity Q-cell (acousto-optic modulator), the laser operates either in the regime of common, rather long and low-power, pulses composed of several sub-pulses or in the one of very short and powerful stimulated Brillouin scattering-induced pulses. The basic physical reason of the laser system to oscillate in one of these two regimes is the existence or absence of CW narrow-line “bad-cavity” lasing in the intervals when the Q-cell is blocked.
All-fiber actively Q-switched Yb-doped laser
2006
Abstract An all-fiber actively Q-switched Yb-doped laser is presented. Q-switching is performed by modulating a fiber Bragg grating via a magnetostrictive rod which is fixed to the fiber at the position of the grating. By exposing the rod to a changing magnetic field, the rod is stretched and relaxed causing the Bragg wavelength of the grating to shift and thereby changes the Q-factor of the cavity. Using Yb-doped fiber, pulses at 1052 nm are obtained at repetition rates from 1 to 200 kHz. At 75 kHz, 0.5 μJ pulses with peak powers of 3 W can be produced when 180 mW of pump power is applied. To the knowledge of the authors, this is the first all-fiber actively Q-switched Yb-doped laser prese…