Search results for "techniques"
showing 10 items of 4426 documents
High-power pulsed dye laser with Fourier-limited bandwidth
1986
A high-peak-power, narrow-linewidth light source with a homogeneous beam profile has been constructed by modifications to a commercially available pulsed-dye-laser system. Output pulses of up to 10 mJ were generated with linewidths of about 50 MHz for 12-nsec pulses. The pulse-to-pulse frequency stability was better than the linewidth, and the center frequency could be scanned over a frequency range of 142.5 GHz at a wavelength of 600 nm. The performance of the system was demonstrated by observing the 6s2 1S0–6s7s1S0 transition in atomic mercury at 2λ = 312.8 nm and the 6s2S1/2–8s2S1/2 transition in atomic gold at 2λ = 308.9 nm using up to 1 mJ of frequency-doubled output for two-photon non…
Simultaneous imaging of the surface and the submembraneous cytoskeleton in living cells by tapping mode atomic force microscopy
1997
Contact and tapping mode atomic force microscopy have been used to visualize the surface of cultured CV-1 kidney cells in aqueous medium. The height images obtained from living cells were comparable when using contact and tapping modes. In contrast, the corresponding, and simultaneously acquired, deflection images differed markedly. Whereas, as expected, deflection images enhanced the surface features in the contact mode, they revealed the presence of a filamentous network when using the tapping mode. This network became disorganized upon addition of cytochalasin, which strongly suggests that it corresponded to the submembraneous cytoskeleton. Examination of fixed cells further supported th…
Large area perovskite light-emitting diodes by gas-assisted crystallization:
2019
Halide perovskites have been gaining considerable attention recently for use in light-emitting applications, due to their bandgap tunability, color purity and low cost fabrication methods. However, current fabrication techniques limit the processing to small-area devices. Here, we show that a facile N 2 gas-quenching technique can be used to make methylammonium lead bromide-based perovskite light-emitting diodes (PeLEDs) with a peak luminance of 6600 cd m −2 and a current efficiency of 7.0 cd A −1 . We use this strategy to upscale PeLEDs to large-area substrates (230 cm 2 ) by developing a protocol for slot-die coating combined with gas-quenching. The resulting large area devices (9 device…
Survival and differentiation of embryonic neural explants on different biomaterials
2006
Biomaterials prepared from polyacrylamide, ethyl acrylate (EA), and hydroxyethyl acrylate (HEA) in various blend ratios, methyl acrylate and chitosan, were tested in vitro as culture substrates and compared for their ability to be colonized by the cells migrating from embryonic brain explants. Neural explants were isolated from proliferative areas of the medial ganglionic eminence and the cortical ventricular zone of embryonic rat brains and cultured in vitro on the different biomaterials. Chitosan, poly(methyl acrylate), and the 50% wt copolymer of EA and HEA were the most suitable substrates to promote cell attachment and differentiation of the neural cells among those tested. Immunofluor…
Influence of saline and pH on collagen type I fibrillogenesis in vitro: Fibril polymorphism and colloidal gold labelling
2007
We have produced different collagen type I fibrils by in vitro fibrillogenesis of acetic acid-soluble collagen within the pH range 2.5-9.0, in the presence and absence of 150 mM NaCl. The varying relatively stable molecular assemblies and polymorphic fibrillar end-products produced after 24 h incubation have been assessed and compared by the TEM study of specimens negatively stained with uranyl acetate. In the presence of 150 mM NaCl, the assembly of collagen at low pH (2.5) leads to the formation of initial molecular aggregates that progressively link together at slightly higher pH (5.0) to form sub-fibrils and spindle-shaped D-banded bundles of sub-fibrils. At pH 6.0 these D-banded bundle…
A Penning Trap for Studying Cluster Ions
1986
We propose to use a Penning trap for spectroscopy of stored cluster ions. A similar device has been built for the purpose of mass measurements of short-lived nuclei produced at the on-line isotope separator ISOLDE/CERN. A resolving power of 500,000 in a mass measurement of39K and an accuracy of 2 × 10−7 for the85Rb/39K mass ratio were obtained. An efficiency for in-flight capture as high as 70% was achieved. The method provides very high sensitivity since typically only 10 to 100 ions are stored in the trap. We intend to perform laser spectroscopy on trapped Na clusters as a first application of the trap technique.
Nondestructive in-line sub-picomolar detection of magnetic nanoparticles in flowing complex fluids
2018
AbstractOver the last decades, the use of magnetic nanoparticles in research and commercial applications has increased dramatically. However, direct detection of trace quantities remains a challenge in terms of equipment cost, operating conditions and data acquisition times, especially in flowing conditions within complex media. Here we present the in-line, non-destructive detection of magnetic nanoparticles using high performance atomic magnetometers at ambient conditions in flowing media. We achieve sub-picomolar sensitivities measuring ~30 nm ferromagnetic iron and cobalt nanoparticles that are suitable for biomedical and industrial applications, under flowing conditions in water and who…
Local electrochemical impedance spectroscopy study of the influence of ageing in air and laser shock processing on the micro-electrochemical behaviou…
2011
International audience; In the present paper, the micro-electrochemical behaviour of AA2050-T8 in 0.1 M NaCl was first studied after polishing by means of local electrochemical impedance spectroscopy and field-emission scanning electron microscopy/electron dispersive spectroscopy (FE-SEM/EDS). The influence of ageing in air and LSP was then investigated. Ageing in air for three months led to an increase in the charge transfer resistance. This was clearly observed in sites surrounding constituent particles where the charge transfer resistance was in the order of 1 MΩ cm2 (instead of 10-3 MΩ cm2 after polishing). Increased passivity around particles was confirmed from FE-SEM/EDS analysis. On …
Implantable Sensors Based on Gold Nanoparticles for Continuous Long-Term Concentration Monitoring in the Body.
2021
Implantable sensors continuously transmit information on vital values or biomarker concentrations in bodily fluids, enabling physicians to survey disease progression and monitor therapeutic success. However, currently available technologies still face difficulties with long-term operation and transferability to different analytes. We show the potential of a generalizable platform based on gold nanoparticles embedded in a hydrogel for long-term implanted biosensing. Using optical imaging and an intelligent sensor/reference-design, we assess the tissue concentration of kanamycin in anesthetized rats by interrogating our implanted sensor noninvasively through the skin. Combining a tissue-integ…
Beta-forging of Ti6Al4V titanium alloy powders consolidated by HIP: Plastic flow and strain-rate relation
2014
Ti6Al4V is probably the best known and studied titanium alloy, not only for aerospace applications. Nevertheless the deformation behavior still represents a challenge if any modification in the deformation process is required or introduced. This work deals with deformation behavior description of Ti6Al4V HIPped powders during high temperature deformation tests carried on in the Beta-region. Laboratory compression and tensile tests have been coupled with relaxation tests in order to achieve robust data about strain rate sensibility m-coefficient and activation energy Q. These results have been fitted for the assessment of a more general exponential deformation law. The final result is a “Dor…