Search results for "tilat"
showing 10 items of 730 documents
Impact of Model Shape Mismatch on Reconstruction Quality in Electrical Impedance Tomography
2012
Electrical impedance tomography (EIT) is a low-cost, noninvasive and radiation free medical imaging modality for monitoring ventilation distribution in the lung. Although such information could be invaluable in preventing ventilator-induced lung injury in mechanically ventilated patients, clinical application of EIT is hindered by difficulties in interpreting the resulting images. One source of this difficulty is the frequent use of simple shapes which do not correspond to the anatomy to reconstruct EIT images. The mismatch between the true body shape and the one used for reconstruction is known to introduce errors, which to date have not been properly characterized. In the present study we…
Suitability of some existing damage indexes for assessing agreements in maintenance and management of museum climatization systems
2020
Heating, Ventilating and Air-Conditioning systems in museums are called to properly control important microclimate parameters, not only for visitors’ wellbeing, but mostly for the preservation of works of art. Accordingly, in case of interruptions to Heating, Ventilating and Air-Conditioning systems, due to maintenance interventions or drawbacks, it is essential to guarantee the acceptable break from service to which possible damages for the works of art are related. In this regard, the aim of this work is to introduce a simple indicator to support curators in regulating the stipulation of contracts with external companies, a more effective management and maintenance of the Heating, V…
On the Phase Separation in n-Type Thermoelectric Half-Heusler Materials
2018
Half-Heusler compounds have been in focus as potential materials for thermoelectric energy conversion in the mid-temperature range, e.g., as in automotive or industrial waste heat recovery, for more than ten years now. Because of their mechanical and thermal stability, these compounds are advantageous for common thermoelectric materials such as Bi 2 Te 3 , SiGe, clathrates or filled skutterudites. A further advantage lies in the tunability of Heusler compounds, allowing one to avoid expensive and toxic elements. Half-Heusler compounds usually exhibit a high electrical conductivity σ , resulting in high power factors. The main drawback of half-Heusler compounds is their high lattice th…
Comparing different processing methods in apple slice drying. Part 1. Performance of microwave, hot air and hybrid methods at constant temperatures
2019
The drying curves, energy efficiency and colour variations of sliced apples dried at various temperatures and using different techniques were evaluated, i.e. microwave (35, 55 and 65 °C), hot air (35, 55, 65 and 75 °C) and combination of both (65 °C). The microwave (MW) tests also included comparison between air recirculation and continuous inlet of fresh air. Each drying method was evaluated at a fixed temperature level by means of a control system based on infrared thermography. The time required to complete the drying process at 65 °C varied from about 44 min for MW with fresh air ventilation (double with air recirculation), to 122 min for hybrid heating and 238 min for hot air. Drying k…
Hyperpolarized helium-3 gas magnetic resonance imaging of the lung.
2003
3He magnetic resonance imaging (MRI) is capable of producing new and regional information on normal and abnormal lung ventilation. The basis of 3He MRI involves "optical pumping" to hyperpolarize the 3He nuclei by photon angular momentum transfer. The hyperpolarized gas is administered via inhalation. 3He is an inert, nontoxic noble gas and absorbed in less than 0.1%. Imaging consists of a four-step protocol. 1) Gas density 3He MRI with high spatial resolution displays the distribution of a 3He bolus in a 10-second breath-hold. An almost homogeneous distribution is regarded as normal. Patients with lung diseases show multiple ventilation defects. 3He MRI has been shown to be more sensitive …
Parked electric car's cabin heat management using photovoltaic powered ventilation system
2019
Abstract This paper explores the use of electric car roof mounted photovoltaic (PV) powered ventilation for cabin heat management/ventilation. A fully-functional Renault Zoe electric car has been used for performance evaluation of parked electric car ventilation directly powered by PV. This work has been part of a research project of testing electric cars in the urban environment and it has been conducted at the Edinburgh Napier University’s Transport Research Institute. In this work, parked electric car ventilation has been reported, when roof-mounted PV modules were used to operate DC powered fans for ventilation. It has been found that the DC motor-fan selection for removing the hot air …
2006
Introduction The objective was to study the effects of a novel lung volume optimization procedure (LVOP) using highfrequency oscillatory ventilation (HFOV) upon gas exchange, the transpulmonary pressure (TPP), and hemodynamics in a porcine model of surfactant depletion. Methods With institutional review board approval, the hemodynamics, blood gas analysis, TPP, and pulmonary shunt fraction were obtained in six anesthetized pigs before and after saline lung lavage. Measurements were acquired during pressure-controlled ventilation (PCV) prior to and after lung damage, and during a LVOP with HFOV. The LVOP comprised a recruitment maneuver with a continuous distending pressure (CDP) of 45 mbar …
Initiation of high-frequency oscillatory ventilation and its effects upon cerebral circulation in pigs: an experimental study
2006
BACKGROUND: Current practice at high-frequency oscillatory ventilation (HFOV) initiation is a stepwise increase of the constant applied airway pressure to achieve lung recruitment. We hypothesized that HFOV would lead to more adverse cerebral haemodynamics than does pressure controlled ventilation (PCV) in the presence of experimental intracranial hypertension (IH) and acute lung injury (ALI) in pigs with similar mean airway pressure settings. METHODS: In 12 anesthetized pigs (24-27 kg) with IH and ALI, mean airway pressure (P(mean)) was increased (to 20, 25, 30 cm H(2)O every 30 min), either with HFOV or with PCV. The order of the two ventilatory modes (cross-over) was randomized. Mean art…
Utilization of mechanical power and associations with clinical outcomes in brain injured patients: a secondary analysis of the extubation strategies …
2023
Background: There is insufficient evidence to guide ventilatory targets in acute brain injury (ABI). Recent studies have shown associations between mechanical power (MP) and mortality in critical care populations. We aimed to describe MP in ventilated patients with ABI, and evaluate associations between MP and clinical outcomes. Methods: In this preplanned, secondary analysis of a prospective, multi-center, observational cohort study (ENIO, NCT03400904), we included adult patients with ABI (Glasgow Coma Scale ≤ 12 before intubation) who required mechanical ventilation (MV) ≥ 24 h. Using multivariable log binomial regressions, we separately assessed associations between MP on hospital day (H…
Ventilación mecánica no invasiva en el postoperatorio. Revisión clínica
2015
Non-invasive ventilation (NIV) is a method of ventilatory support that is increasing in importance day by day in the management of postoperative respiratory failure. Its role in the prevention and treatment of atelectasis is particularly important in the in the period after thoracic and abdominal surgeries. Similarly, in the transplanted patient, NIV can shorten the time of invasive mechanical ventilation, reducing the risk of infectious complications in these high-risk patients. It has been performed A systematic review of the literature has been performed, including examining the technical, clinical experiences and recommendations concerning the application of NIV in the postoperative per…