Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study
2015
BACKGROUND: In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive respiratory conditions. METHODS: A test lung, connected to a pediatric mannequin using different interfaces (endotracheal tube [ETT], face mask, and helmet), was ventilated in pressure support ventilation mode testing 2 ventilator settings (pressurization time [Timepress]50%/cycling-off flow threshold [T…
Long-term volume-targeted pressure-controlled ventilation: sense or nonsense?
2017
The technology underlying the development of novel ventilatory modes for long-term noninvasive ventilation of patients with chronic hypercapnia is continuously evolving. Volume-targeted pressure-controlled ventilation is a hybrid ventilation mode designed to combine the advantages of conventional ventilation modes, while avoiding their drawbacks. However, manufacturers have created different names and have patented algorithms and set-up variables, which can result in confusion for physicians and respiratory therapists. In addition, clear evidence for the superiority of this novel mode has not yet been established. These factors have most likely hindered more widespread use of this mode in c…
Secretion Management Must Be Considered When Reporting Success or Failure of Noninvasive Ventilation
2003
Patient-Ventilator Asynchronies: Clinical Implications and Practical Solutions
2020
Mechanical ventilation is a supportive treatment commonly applied in critically ill patients. Whenever the patient is spontaneously breathing, the pressure applied to the respiratory system depends on the sum of the pressure generated by the respiratory muscles and the pressure generated by the ventilator. Patient-ventilator interaction is of utmost importance in spontaneously breathing patients, and thus the ventilator should be able to adapt to patient's changes in ventilatory demand and respiratory mechanics. Nevertheless, a lack of coordination between patient and ventilator due to a mismatch between neural and ventilator timing throughout the respiratory cycle may make weaning difficul…
Prevalence and risk factors for delirium in critically ill patients with COVID-19 (COVID-D): a multicentre cohort study
2021
Background: To date, 750 000 patients with COVID-19 worldwide have required mechanical ventilation and thus are at high risk of acute brain dysfunction (coma and delirium). We aimed to investigate the prevalence of delirium and coma, and risk factors for delirium in critically ill patients with COVID-19, to aid the development of strategies to mitigate delirium and associated sequelae. Methods: This multicentre cohort study included 69 adult intensive care units (ICUs), across 14 countries. We included all patients (aged ≥18 years) admitted to participating ICUs with severe acute respiratory syndrome coronavirus 2 infection before April 28, 2020. Patients who were moribund or had life-suppo…
185 * RED BLOOD CELL DISTRIBUTION WIDTH PREDICTS MORBIDITY AND MORTALITY AFTER AORTIC VALVE REPLACEMENT
2014
Dynamic determination of oxygenation and lung compliance in murine pneumonectomy.
2011
Thoracic surgical procedures in mice have been applied to a wide range of investigations, but little is known about the murine physiologic response to pulmonary surgery. Using continuous arterial oximetry monitoring and the FlexiVent murine ventilator, the authors investigated the effect of anesthesia and pneumonectomy on mouse oxygen saturation and lung mechanics. Sedation resulted in a dose-dependent decline of oxygen saturation that ranged from 55% to 82%. Oxygen saturation was restored by mechanical ventilation with increased rate and tidal volumes. In the mouse strain studied, optimal ventilatory rates were a rate of 200/minute and a tidal volume of 10 mL/kg. Sustained inflation pressu…
Ventilator Settings to Avoid Nuisance Alarms During Mouthpiece Ventilation
2016
BACKGROUND: A recent study found that activation of disconnection and low-pressure alarms is common during mouthpiece ventilation and may represent a major limitation to its use. The aim of this bench study was: (1) to investigate the technical aspects that can influence the setting of the ventilator during mouthpiece ventilation and (2) to provide a practical setting strategy to avoid the alarm activation. METHODS: Eight life-support ventilators able to deliver volume controlled ventilation were tested in a bench study using a single-limb non-vented circuit configuration connected to a standard mouthpiece. Disconnection and apnea alarm were turned off or set at the least sensitive setting.…
The right interface for the right patient in noninvasive ventilation: a systematic review
2022
Introduction Research in the field of noninvasive ventilation (NIV) has contributed to the development of new NIV interfaces. However, interface tolerance plays a crucial role in determining the beneficial effects of NIV therapy. Areas covered This systematic review explores the most significant scientific research on NIV interfaces, with a focus on the potential impact that their design might have on treatment adherence and clinical outcomes. The rationale on the choice of the right interface among the wide variety of devices that are currently available is discussed here. Expert opinion The paradigm 'The right mask for the right patient' seems to be difficult to achieve in real life. Rang…
Accuracy of Nasal Pressure Swing to Predict Failure of High-Flow Nasal Oxygen in Patients with Acute Hypoxemic Respiratory Failure
2023
In a real-life cohort of patients with AHRF undergoing HFNO, ΔPnose showed excellent accuracy in predicting early failure, similar of that displayed by ROX. Giving that the decision to upgrade to NIV or MV was based on clinical variables, the high accuracy of ROX in predicting failure of HFNO is not surprising. The similar accuracy of ΔPnose (the only measurement that remained blinded to our clinical decision), strengthened the association with outcome, avoiding incorporation bias.