Search results for "uci"

showing 10 items of 5317 documents

Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields

1996

Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtyAdolescentgenetic structuresSiliconesOcular hypertensionGlaucomaSensitivity and SpecificityGoldmann applanation tonometryChemical disinfectionTonometry Ocularchemistry.chemical_compoundSiliconeDouble-Blind MethodOphthalmologymedicineHumansChildDisposable EquipmentIntraocular PressureAgedAged 80 and overAlternative methodsbusiness.industryReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesSurgeryOphthalmologychemistryEvaluation Studies as TopicInfertilityFemaleOcular Hypertensionsense organsbusinessOphthalmology
researchProduct

Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects

2006

To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresEye diseaseVisual AcuityGlaucomaGoldmann applanation tonometryCorneaTonometry OcularOphthalmologyHumansMedicineProspective StudiesIntraocular PressureAgedUltrasonographyAged 80 and overbusiness.industryLimits of agreementHealthy subjectsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVisual Field TestsFemaleOcular Hypertensionsense organsbusinessAmerican Journal of Ophthalmology
researchProduct

Validation of the German Version of the Quality of Dying and Death Questionnaire for Health Professionals

2016

Purpose: To validate the Quality of Dying and Death (QoDD) instrument for health professionals (QoDD-D-MA) and to test its feasibility in 2 German palliative care units (PCUs). Methods: The QoDD was translated from English to German and then retranslated following European Organisation for Research and Treatment of Cancer (EORTC) guidelines. Data were collected in 2 German PCUs to calculate aspects of validity and reliability. Results: Mean total score was 83.05 (range 49-100; N = 232). The QoDD-D-MA showed satisfactory psychometric properties, Cronbach α = .830; interrater reliability r = .245 ( P < .01). The QoDD-D-MA was independent of patients’ demographic and clinical aspects. Some …

AdultMaleAttitude to DeathPalliative carePsychometricsHealth Personnelmedia_common.quotation_subject-German03 medical and health sciences0302 clinical medicineNursingCronbach's alphaMedizinische FakultätGermanySurveys and QuestionnairesHumansMedicineQuality (business)ddc:610030212 general & internal medicineReliability (statistics)Agedmedia_commonAged 80 and overbusiness.industryPalliative CareReproducibility of ResultsGeneral MedicineMiddle AgedTranslatingMissing datalanguage.human_languageTest (assessment)Inter-rater reliability030220 oncology & carcinogenesisQuality of LifelanguageFemalebusinessAmerican Journal of Hospice and Palliative Medicine®
researchProduct

COMPARISON OF T-1 ESTIMATION TECHNIQUES IN CARDIAC MRI

1994

International audience; Abstract: We have shown that the use of a simple combination of inversion recovery/spin-echo (IR/SE) sequences provides undeniably superior precision in quantitative in vivo myocardium T-1 estimation than the standard multiple spin-echo approach. On a group of 25 healthy subjects, the T-1 dispersion was, respectively, 3.8% for the IR/SE combination and 19.6% for the best SE pair combination. Moreover, repeated measurements were carried out on seven of the volunteers in order to assess T-1 reproducibility. The mean intra-individual T-1 precision was found to be 2.8% for the IR/SE pair and 20.0% for the best SE pair. The in vivo imaging work was supported and corrobora…

AdultMaleBiomedical EngineeringBiophysicsInversion recovery030204 cardiovascular system & hematologyTISSUE CHARACTERIZATION030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineNuclear magnetic resonanceCARDIAC MRIQUALITY CONTROL[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansRadiology Nuclear Medicine and imagingMathematicsReproducibility[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingHealthy subjectsHeartTissue characterizationT-1Magnetic Resonance ImagingFemalePreclinical imaging
researchProduct

Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability

2001

Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…

AdultMaleBiometryLightInterobserver reliabilityAnterior ChamberEmmetropiaData descriptionCorneaOptical biometryOpticsMyopiaHumansReliability (statistics)AgedMathematicsObserver VariationReproducibilitybusiness.industryCorneal TopographyReproducibility of ResultsMiddle AgedSensory SystemsOphthalmologyInterferometryPartial coherence interferometryFemaleSurgerybusinessNuclear medicinePartial coherenceJournal of Cataract and Refractive Surgery
researchProduct

Interchangeability among five devices that measure anterior eye distances.

2014

The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…

AdultMaleBiometrybusiness.industryAnterior ChamberMeasure (physics)Corneal TopographyReproducibility of ResultsEquipment DesignRefraction OcularRefractive ErrorsInterchangeabilityCorneaOphthalmologyYoung AdultOpticsOptometryMedicineHumansFemaleProspective StudiesbusinessOptometryFollow-Up StudiesClinicalexperimental optometry
researchProduct

Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.

2020

To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p  0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …

AdultMaleBiometrygenetic structuresBiometricsComputer scienceAnterior ChamberBiomedical EngineeringHigh resolution030204 cardiovascular system & hematologyEye03 medical and health sciencesYoung Adult0302 clinical medicineOpticsOptical coherence tomographyLens CrystallinemedicineHumansAgedmedicine.diagnostic_testbusiness.industryReproducibility of ResultsPupilGeneral MedicineCoherence (statistics)RepeatabilityMiddle Agedeye diseasesSurgeryFemalesense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceExpert review of medical devices
researchProduct

Differential contributions of ankle plantarflexors during submaximal isometric muscle action: A PET and EMG study

2014

Abstract The objective of this study was to investigate the relative contributions of superficial and deep ankle plantarflexors during repetitive submaximal isometric contractions using surface electromyography (SEMG) and positron emission tomography (PET). Myoelectric signals were obtained from twelve healthy volunteers (27.3±4.2yrs). A tracer ([ 18 F]-FDG) was injected during the exercise and PET scanning was done immediately afterwards. The examined muscles included soleus (Sol), medial gastrocnemius (MG), lateral gastrocnemius (LG), and flexor hallucis longus (FHL). It was found that isometric maximal voluntary contraction (MVC) force, muscle glucose uptake (GU) rate, and SEMG of variou…

AdultMaleBiophysicsNeuroscience (miscellaneous)Isometric exerciseElectromyographyYoung AdultMuscle actionIsometric ContractionHealthy volunteersmedicineHumansExercise physiologyMuscle Skeletalta315ExerciseLegArthrometry Articularmedicine.diagnostic_testElectromyographybusiness.industryBiomechanicsAnatomymusculoskeletal systemMagnetic Resonance ImagingHealthy VolunteersGlucosemedicine.anatomical_structureFlexor hallucis longusPositron-Emission TomographyFemaleNeurology (clinical)AnkleAnklebusinessNuclear medicineJournal of Electromyography and Kinesiology
researchProduct

Screening for Autoantibodies to Tissue Transglutaminase Reveals a Low Prevalence of Celiac Disease in Blood Donors with Cryptogenic Hypertransaminase…

2001

Patients with chronic cryptogenic hypertransaminasemia are at high risk of developing celiac disease (CD). In fact, among the various serological disorders, CD patients at onset frequently present hypertransaminasemia. In this study, we evaluated usefulness and reliability of the new test for antitissue transglutaminase (tTG) in screening for CD as well as in estimating the prevalence of CD in a population of blood donors presenting unexplained hypertransaminasemia at donation. Controls were 180 consecutive healthy donors without hypertransaminasemia and 20 CD patients with known antiendomysial antibody (EmA) positivity. Out of 22,204 blood donors over a period of 2 years, we found 258 subj…

AdultMaleBlood donormedicine.medical_specialtyTissue transglutaminasePopulationE2F6 Transcription FactorBlood DonorsEnzyme-Linked Immunosorbent AssaySensitivity and SpecificityGastroenterologyCoeliac diseaseSerologyIntestinal mucosaInternal medicineImmunopathologyBiopsyPrevalencemedicineHumansCeliac diseaseIntestinal MucosaFluorescent Antibody Technique IndirecteducationTransaminasesAutoantibodieseducation.field_of_studyTransglutaminasesbiologymedicine.diagnostic_testbusiness.industryGastroenterologyAutoantibodyReproducibility of ResultsMiddle Agedmedicine.diseaseTransglutaminaseRepressor ProteinsImmunologybiology.proteinFemalebusinessTranscription FactorsDigestion
researchProduct

Rapid and reliable genotyping procedure for detection of alleles with mutations, deletion, or/and duplication of the CYP2D6 gene

2009

Abstract Background Polymorphisms of cytochrome P450 2D6 (CYP2D6) have a significant effect on the pharmacokinetics of most tricyclic antidepressants. More than 150 alleles lead to four distinct phenotypes of drug metabolism. The phenotypes are described as ultrarapid, extensive, intermediate, and poor metabolizers. Therapeutic plasma levels of CYP2D6 substrates may be difficult to achieve. Here we describe a rapid and reliable procedure for CYP2D6*4, *3, *6, and *9 genotyping. Design and methods Serum concentrations of venlafaxine and its pharmacologically active metabolite, O-desmethylvenlafaxine, were measured in patients treated with the antidepressant venlafaxine, a substrate of CYP2D6…

AdultMaleCYP2D6GenotypeDNA Mutational AnalysisMolecular Sequence DataClinical BiochemistrySingle-nucleotide polymorphismBiologyPolymerase Chain ReactionSensitivity and Specificitydigestive systemGene DuplicationGene duplicationGenotypeHumansAlleleskin and connective tissue diseasesGeneGenotypingAllelesSequence DeletionGeneticsPolymorphism GeneticBase SequenceDepressionVenlafaxine HydrochlorideReproducibility of ResultsSequence Analysis DNAGeneral MedicineMiddle AgedCyclohexanolsMolecular biologyReal-time polymerase chain reactionCytochrome P-450 CYP2D6MutationAntidepressive Agents Second-GenerationFemaleClinical Biochemistry
researchProduct