Search results for "valves"

showing 10 items of 62 documents

New flow-multicommutation method for the photo-chemiluminometric determination of the carbamate pesticide asulam

2004

This paper deals with a straightforward automated method for the determination of asulam in water based on the use of a flow manifold including three computer-controlled solenoid valves. The method involves irradiating on an aqueous solution of asulam in glycine buffer at pH 8.3 with UV light during 90 s, then follows the oxidation with potassium permanganate in a sulphuric medium and chemiluminescence-based detection of the resulting photoproducts. The limit of detection thus achieved is 40 mug l(-1). The detector response is linear up to a 5 mg l(-1) asulam concentration and the throughput is 30 samples h(-1). In parallel tests, oxidation with alkaline ferricyanide was also assessed and t…

Detection limitChemiluminescenceChromatographyAqueous solutionSolenoid valvesBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganateAsulamchemistrylawMulticommutationReagentPhotodegradationQUIMICA ANALITICAEnvironmental ChemistryAsulamFerricyanidePhotodegradationSpectroscopyChemiluminescenceAnalytica Chimica Acta
researchProduct

Novel molluskan biomineralization proteins retrieved from proteomics: a case study with upsalin.

2012

12 pages; International audience; The formation of the molluskan shell is regulated by an array of extracellular proteins secreted by the calcifying epithelial cells of the mantle. These proteins remain occluded within the recently formed biominerals. To date, many shell proteins have been retrieved, but only a few of them, such as nacreins, have clearly identified functions. In this particular case, by combining molecular biology and biochemical approaches, we performed the molecular characterization of a novel protein that we named Upsalin, associated with the nacreous shell of the freshwater mussel Unio pictorum. The full sequence of the upsalin transcript was obtained by RT-PCR and 5'/3…

ElectrophoresisMolecular Sequence DataBiologyProteomicsBioinformaticsBiochemistryHomology (biology)03 medical and health sciencesproteomicsGene silencingAnimalsAmino Acid Sequence[SDV.IB.BIO]Life Sciences [q-bio]/Bioengineering/BiomaterialsMolecular BiologyPeptide sequence030304 developmental biology0303 health sciencesMineralsBase Sequence030302 biochemistry & molecular biologyOrganic ChemistrymollusksImmunogold labelling[ SDV.IB.BIO ] Life Sciences [q-bio]/Bioengineering/BiomaterialsbiomineralizationIn vitroproteinsfreshwater bivalvesBiochemistryMolluscaMicroscopy Electron ScanningMolecular MedicineTarget proteinBiomineralization
researchProduct

Effects of Rastering Velocity on Electrospun Polyeurthane Structure and Mechanical Properties

2010

Electrospun Polyeurthane Scaffolds Mechanical Properties Rastering Velocity Heart Valves
researchProduct

Fabrication of elastomeric scaffolds with curvilinear fibrous structures for heart valve leaflet engineering

2014

Native semi-lunar heart valves are composed of a dense fibrous network that generally follows a curvilinear path along the width of the leaflet. Recent models of engineered valve leaflets have predicted that such curvilinear fiber orientations would homogenize the strain field and reduce stress concentrations at the commissure. In the present work, a method was developed to reproduce this curvilinear fiber alignment in electrospun scaffolds by varying the geometry of the collecting mandrel. Elastomeric poly(ester urethane)urea was electrospun onto rotating conical mandrels of varying angles to produce fibrous scaffolds where the angle of fiber alignment varied linearly over scaffold length.…

Heart ValvemicrostructureBiomedical EngineeringBiocompatible MaterialsElastomerCeramics and CompositeArticleCardiac Valve AnnuloplastyTissue ScaffoldBiomimetic MaterialsMaterials TestingHumanselectrospinningBiocompatible MaterialPulmonary ValveTissue ScaffoldsTissue Engineeringtechnology industry and agricultureModels CardiovascularHeart ValvesBiomaterialBiomechanical PhenomenaElastomerspolyurethanecardiac valve2506Biomimetic MaterialHuman
researchProduct

Preliminary Short-term Results of a Population of Patients Treated with MitraClip therapy: one Center Experience

2017

<p><span>Objectives: This retrospective analysis sought to evaluate 1-month outcomes and therapy effectiveness of a population of patients treated with MitraClip therapy. We describe in this article the preliminary results of primary effictiveness endpoint.</span></p><p><span>Background: Percutaneous Mitral Repair is being developed to treat severe mitral regurgitation (MR),with increasing real-world cases of functional MR(FMR). In the EVEREST(Endovascular Valve Edge-to-Edge Repair Study)II trial,percutaneous device showed superior safety but less reduction in MR at 1year. 4-year outcomes from EVEREST II trial showed no difference in the prevalence of mod…

Heart valvesmedicine.medical_specialtyeducation.field_of_studyMitral regurgitationlcsh:Diseases of the circulatory (Cardiovascular) systemPercutaneousbusiness.industryMitraClipPopulationlcsh:Rlcsh:MedicinePercutaneous approachNyha classNew york heart associationSurgerylcsh:RC666-701MedicineFunctional mrMitraClipbusinesseducationCatheter-based therapyNYHA functional classMitral RegurgitationInternational Cardiovascular Forum Journal
researchProduct

Ultrastructure of the Interlamellar Membranes of the Nacre of the Bivalve Pteria hirundo, Determined by Immunolabelling.

2015

The current model for the ultrastructure of the interlamellar membranes of molluscan nacre imply that they consist of a core of aligned chitin fibers surrounded on both sides by acidic proteins. This model was based on observations taken on previously demineralized shells, where the original structure had disappeared. Despite other earlier claims, no direct observations exist in which the different components can be unequivocally discriminated. We have applied different labeling protocols on non-demineralized nacreous shells of the bivalve Pteria. With this method, we have revealed the disposition and nature of the different fibers of the interlamellar membranes that can be observed on the …

In situPlateletsBivalvesScanning electron microscopeShell (structure)Mineralogylcsh:MedicineChitinMatrix (biology)chemistry.chemical_compoundChitinAnimal ShellsMembrane proteinsAnimalsFiberlcsh:ScienceNacreFluorescence microscopyMultidisciplinaryMicroscopy Confocallcsh:RfungiProteasesMolluscs[ SDV.IB.BIO ] Life Sciences [q-bio]/Bioengineering/BiomaterialsBivalviaMembraneAragonitechemistryBiophysicsUltrastructureMicroscopy Electron Scanninglcsh:QResearch ArticlePloS one
researchProduct

Automated simultaneous triple dissolution profiles of two drugs, sulphamethoxazole-trimethoprim and hydrochlorothiazide-captopril in solid oral dosag…

2003

This article deals with the simultaneous determination of three dissolution profiles with the aid of the new and emerging continuous-flow methodology known as multicommutation. This methodology is based on a flow network of a set of solenoid valves controlled by the computer and acting as independent multicommutators to allow the easy and automated control of flowing solutions. The obtained three dissolution profiles from one dosage form are the whole formulation profile or "global profile" recommended by pharmacopoeias, and, at same time, are recorded two "individual" profiles from two drugs present in the formulation. This is the second attempt to obtain simultaneously three dissolution p…

In vitro availabilityCaptoprilStereochemistryClinical BiochemistryDissolution profilesPharmaceutical ScienceAdministration OralDerivativeTrimethoprimDosage formAnalytical ChemistryHydrochlorothiazideSpectrophotometryQUIMICA ANALITICADrug DiscoveryTrimethoprim Sulfamethoxazole Drug CombinationmedicineSolenoid valves multicommutationDissolutionSpectroscopyAntibacterial agentDosage FormsChromatographymedicine.diagnostic_testChemistryCaptoprilHydrochlorothiazideFlow (mathematics)SolubilityPharmaceuticalsSpectrophotometry UltravioletSulphamethoxazolemedicine.drugJournal of pharmaceutical and biomedical analysis
researchProduct

Independent Geometrical Control of Spin and Charge Resistances in Curved Spintronics

2019

Spintronic devices operating with pure spin currents represent a new paradigm in nanoelectronics, with higher energy efficiency and lower dissipation as compared to charge currents. This technology, however, will be viable only if the amount of spin current diffusing in a nanochannel can be tuned on demand while guaranteeing electrical compatibility with other device elements, to which it should be integrated in high-density three-dimensional architectures. Here, we address these two crucial milestones and demonstrate that pure spin currents can effectively propagate in metallic nanochannels with a three-dimensional curved geometry. Remarkably, the geometric design of the nanochannels can b…

LetterChemistry(all)geometrical controlFOS: Physical sciencesBioengineeringRELAXATIONApplied Physics (physics.app-ph)02 engineering and technologySpin current7. Clean energyelectrical and spin resistanceMaterials Science(all)National Graphene InstituteOn demandMesoscale and Nanoscale Physics (cond-mat.mes-hall)LOGICGeneral Materials ScienceElectronicsPhysicsspintronicsCondensed Matter - Mesoscale and Nanoscale PhysicsSpintronicsbusiness.industryMechanical EngineeringMEMORYnon-local spin valvesPhysics - Applied PhysicsGeneral ChemistrySpintronicsDissipation021001 nanoscience & nanotechnologyCondensed Matter PhysicsTRANSPORTROOM-TEMPERATURENanoelectronicsnonlocal spin valvesMETALResearchInstitutes_Networks_Beacons/national_graphene_institutecurved nanoarchitectures; electrical and spin resistance; geometrical control; nonlocal spin valves; SpintronicsOptoelectronicscurved nanoarchitecturesINJECTION0210 nano-technologybusinessEfficient energy useNano Letters
researchProduct

Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement

2013

Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…

Malemedicine.medical_specialtyCardiac CatheterizationTranscatheter aorticAortic rootmedicine.medical_treatmentAortic Rupturemultidetector computed tomographySettore MED/11 - Malattie dell'Apparato CardiovascolareCohort StudiesValve replacementPredictive Value of TestsRisk FactorsPhysiology (medical)Internal medicineMultidetector computed tomographymedicine80 and overVentricular outflow tractHumanscardiovascular diseasesannular calcification; annular rupture; multidetector computed tomography; transcatheter heart valves; Aged; Aged 80 and over; Angioplasty Balloon; Aortic Rupture; Aortic Valve; Aortic Valve Stenosis; Calcinosis; Cohort Studies; Female; Heart Valve Prosthesis Implantation; Humans; Logistic Models; Male; Predictive Value of Tests; Risk Factors; Tomography X-Ray Computed; Cardiac CatheterizationTomographyAgedAged 80 and overHeart Valve Prosthesis Implantationbusiness.industrySinotubular JunctionAngioplastyCalcinosisAortic Valve Stenosismedicine.diseaseX-Ray ComputedBalloon expandable stentLogistic Modelstranscatheter heart valvesAortic ValveCardiologycardiovascular systemannular ruptureFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAngioplasty BalloonBalloonCalcificationannular calcification
researchProduct

Low intrinsic carrier density LSMO/Alq3/AlOx/Co organic spintronic devices

2018

The understanding of spin injection and transport in organic spintronic devices is still incomplete, with some experiments showing magnetoresistance and others not detecting it. We have investigated the transport properties of a large number of tris-(8-hydroxyquinoline)aluminum-based organic spintronic devices with an electrical resistance greater than 5 MΩ that did not show magnetoresistance. Their transport properties could be described satisfactorily by known models for organic semiconductors. At high voltages (>2 V), the results followed the model of space charge limited current with a Poole-Frenkel mobility. At low voltages (∼0.1 V), that are those at which t…

Materials sciencePhysics and Astronomy (miscellaneous)MagnetoresistanceSpintronicsCondensed matter physicsVALVESSpin valve02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesSpace chargePoole–Frenkel effectTRANSPORTOrganic semiconductorINTERFACESPIN INJECTIONElectrical resistance and conductanceElectrical resistivity and conductivity0103 physical sciencesMAGNETORESISTANCEHETEROJUNCTIONfilms010306 general physics0210 nano-technologyTEMPERATURE
researchProduct