Search results for "visio"

showing 10 items of 5207 documents

Studies on the subcellular pathophysiology of sublethal chronic cell injury.

1974

Summary This paper summarizes some of the important subcellular events occurring after chronic sublethal cell injury. Chronic cell injury is defined as the result of injurious stimuli which permit cell survival though in altered steady states for protracted periods of time. The importance of ultrastructural and biochemical studies of these phenomena is emphasized. Among the phenomena discussed are alterations in lysosomes, cellular hypertrophy, fatty metamorphosis, alterations in microfilaments and microtubules, alterations in mechanisms of transcription and replication, disturbances in the cell surface and transport across the cell membrane, and alterations in intracellular transport.

AdultMaleTime FactorsTranscription GeneticSurface PropertiesCellsCellGuinea PigsBronchiBiologyMicrofilamentMicrotubulesPathology and Forensic MedicineMuscle hypertrophyCell Physiological PhenomenaCell membraneMiceMicrotubuleTranscription (biology)medicineAnimalsHumansCerebral CortexMacrophagesMusclesCell MembraneBiological TransportGeneral MedicineHypertrophyMiddle AgedPathophysiologyCell biologyMicroscopy Electronmedicine.anatomical_structureLiverUltrastructureRabbitsLysosomesCell DivisionBeitrage zur Pathologie
researchProduct

Parafoveal versus foveal N400s dissociate spreading activation from contextual fit.

2009

Using concurrent electroencephalogram and eye movement measures to track natural reading, this study shows that N400 effects reflecting predictability are dissociable from those owing to spreading activation. In comparing predicted sentence endings with related and unrelated unpredicted endings in antonym constructions ('the opposite of black is white/yellow/nice'), fixation-related potentials at the critical word revealed a predictability-based N400 effect (unpredicted vs. predicted words). By contrast, event-related potentials time locked to the last fixation before the critical word showed an N400 only for the nonrelated unpredicted condition (nice). This effect is attributed to a parafo…

AdultMaleTime Factorsgenetic structuresmedia_common.quotation_subjectVocabularyPsycholinguisticsThinkingYoung AdultFovealContrast (vision)HumansPredictabilityEvoked PotentialsEye Movement Measurementsmedia_commonCommunicationbusiness.industryGeneral NeuroscienceEye movementBrainElectroencephalographyN400SemanticsReadingFixation (visual)FemalebusinessPsychologySentenceCognitive psychologyNeuroreport
researchProduct

Visual distraction: a behavioral and event-related brain potential study in humans.

2006

Recent studies reported that the detection of changes in the visual stimulation results in distraction of cognitive processing. From event-related brain potentials it was argued that distraction is triggered by the automatic detection of deviants. We tested whether distraction effects are confined to the detection of a deviation or can be triggered by changes per se, namely by rare stimuli that were not deviant with respect to the stimulation. The results obtained comparable early event-related brain potential effects for rare and deviant stimuli, suggesting an automatic detection of these changes. In contrast, behavioral distraction and attention-related event-related brain potential compo…

AdultMaleTime Factorsmedia_common.quotation_subjecteducationMismatch negativityPoison controlStimulationbehavioral disciplines and activitiesDevelopmental psychologyDiscrimination PsychologicalPerceptionDistractionmental disordersReaction TimeContrast (vision)HumansAttentionmedia_commonBrain MappingGeneral NeuroscienceBrainCognitionElectroencephalographyhumanitiesElectrophysiologyPattern Recognition VisualEvoked Potentials VisualFemalePsychologyNeurosciencepsychological phenomena and processesPhotic StimulationPsychomotor PerformanceNeuroreport
researchProduct

Impairments in top down attentional processes in right parietal patients: Paradoxical functional facilitation in visual search

2014

AbstractIt is well known that the right posterior parietal cortex (PPC) is involved in attentional processes, including binding features. It remains unclear whether PPC is implicated in top-down and/or bottom-up components of attention. We aim to clarify this by comparing performance of seven PPC patients and healthy controls (HC) in a visual search task involving a conflict between top-down and bottom-up processes. This task requires essentially a bottom-up feature search. However, top-down attention triggers feature binding for object recognition, designed to be irrelevant but interfering to the task. This results in top-down interference, prolonging the search reaction time. This interfe…

AdultMaleTop-down attentiongenetic structuresmedicine.medical_treatmentPosterior parietal cortexbehavioral disciplines and activities050105 experimental psychologyParietal cortexTask (project management)03 medical and health sciences0302 clinical medicineParietal LobemedicineHumans0501 psychology and cognitive sciencesAttentionVisual searchParietal patientsSettore M-PSI/02 - Psicobiologia E Psicologia FisiologicaBrain NeoplasmsVisual search05 social sciencesCognitive neuroscience of visual object recognitionTop-down and bottom-up designMiddle AgedSensory SystemsTranscranial magnetic stimulationStrokeOphthalmologyFeature (computer vision)Case-Control StudiesParadoxical functional facilitationFacilitationVisual PerceptionFemalePsychologyNeuroscience030217 neurology & neurosurgeryPhotic Stimulationpsychological phenomena and processesCognitive psychologyBottom-up attentionVision Research
researchProduct

Response of the aging eye to first day of modern material contact lens wear

2018

Objectives: To investigate the ocular surface of an aged population wearing a daily disposable contact lens over their first day of wear. Methods: Forty eyes from forty presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA) and ocular surface aberrations (total higher order root means square (RMS)) were assessed at baseline (t0), at 20 minutes (t1) and after 8 hours (t2) of wear. Fluorescein corneal and conjunctival staining and tear break up time (TBUT) were performed at t0 and t2. Results: No statistically significant changes were found between t0, t1 and t2 for TMA, and between t0 and t2 for fluorescein corneal and conjunctival staining. TBUT…

AdultMaleUlls Acomodació i refracciómedicine.medical_specialtyAgingPopulationBaseline levelCornea03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOphthalmologymedicineHumansProspective StudiesFluoresceineducationDisposable EquipmentVision OcularOsmoleeducation.field_of_studyOsmotic concentrationbusiness.industryOsmolar ConcentrationEquipment DesignPresbyopiaMiddle AgedContact Lenses HydrophilicTear osmolarityeye diseasesÒptica Aparells i instrumentsContact lensOphthalmologyTear meniscuschemistryPatient SatisfactionTears030221 ophthalmology & optometryDry Eye SyndromesFemalesense organsbusinessConjunctiva030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

DaVinci's Mona Lisa entering the next dimension.

2013

For several of Leonardo da Vinci's paintings, such as The Virgin and Child with St Anne or the Mona Lisa, there exist copies produced by his own studio. In case of the Mona Lisa, a quite exceptional, rediscovered studio copy was presented to the public in 2012 by the Prado Museum in Madrid. Not only does it mirror its famous counterpart superficially; it also features the very same corrections to the lower layers, which indicates that da Vinci and the ‘copyist’ must have elaborated their panels simultaneously. On the basis of subjective (thirty-two participants estimated painter-model constellations) as well as objective data (analysis of trajectories between landmarks of both paintings), …

AdultMaleVision DisparityFamous Personsmedia_common.quotation_subjectArt historyExperimental and Cognitive PsychologyObjective dataYoung AdultOpticsArtificial IntelligenceHumansDimension (data warehouse)media_commonPaintingDepth Perceptionbusiness.industryMuseumsPerspective (graphical)ArtSensory SystemsOphthalmologyStereopsisHistory 16th CenturyBinocular disparityFemalePaintingsbusinessMona lisaStudioPerception
researchProduct

Monocular Versus Binocular Calibrations in Evaluating Fixation Disparity With a Video-Based Eye-Tracker

2015

When measuring fixation disparity (an oculomotor vergence error), the question arises as to whether a monocular or binocular calibration is more precise and physiologically more appropriate. In monocular calibrations, a single eye fixates on a calibration target that is taken as having been projected onto the center of the fovea; the corresponding vergence state represents the heterophoria (the resting vergence position), which has no effect on the calibration procedure. In binocular calibrations, a vergence error may be present and may affect the subsequent measurement of the fixation disparity during binocular recordings. This study includes a test of the precision of both monocular and …

AdultMaleVision Disparitygenetic structuresComputer scienceVideo RecordingExperimental and Cognitive PsychologyFixation OcularVergenceRetinaYoung AdultOpticsVision MonocularArtificial Intelligenceparasitic diseasesHumansComputer visionVision BinocularMonocularbusiness.industryVision DisparityConvergence Oculareye diseasesSensory SystemsStrabismusElectrooculographyOphthalmologyHeterophoriaCalibrationEye trackingBinocular disparityFemaleArtificial intelligenceFixation disparitybusinessBinocular visionPerception
researchProduct

Visual performance of two simultaneous vision multifocal contact lenses

2012

Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…

AdultMaleVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual Acuitylaw.inventionContrast SensitivitylawmedicineHumansContrast (vision)media_commonVision BinocularCross-Over Studiesbusiness.industryIntermediate distanceBoth lensesPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyOptometryFemalemedicine.symptombusinessOptometryPhotopic visionOphthalmic and Physiological Optics
researchProduct

Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.

2007

To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…

AdultMaleVisual acuitygenetic structuresPseudophakiaMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularMedicineContrast (vision)HumansProspective Studiesmedia_commonAgedQuality Indicators Health CareAged 80 and overLenses IntraocularVision BinocularMonocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyQuality of visionOptometrySurgeryFemalesense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual function after implantation of a diffractive aspheric trifocal intraocular lens

2016

Purpose To evaluate distance, intermediate, and near vision after bilateral implantation of a diffractive aspheric trifocal intraocular lens (IOL). Methods This study enrolled 204 eyes of 102 patients who had bilateral implantation of the AT LISA tri 839MP IOL. Monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (4 meters), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (30, 40 centimeters), binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) (50, 60, 70 centimeters), the defocus curve, and binocular photopic…

AdultMaleVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignRefraction OcularGlareContrast Sensitivity03 medical and health sciencesNear visionOcular physiology0302 clinical medicineLens Implantation IntraocularMedicineHumansProspective StudiesAgedLenses IntraocularVision BinocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationMiddle Agedeye diseasesOphthalmologyVisual function030221 ophthalmology & optometryOptometryFemalemedicine.symptombusinessBinocular vision030217 neurology & neurosurgeryPseudophakia
researchProduct