0000000000025612

AUTHOR

María Amparo Díez-ajenjo

Looking for the dichromatic version of a colour vision model

Different hypotheses on the sensitivity of photoreceptors and post-receptoral mechanisms were introduced in different colour vision models to derive acceptable dichromatic versions. Models with one (Ingling and T'sou, Guth et al, Boynton) and two linear opponent stages (DeValois and DeValois) and with two non-linear opponent stages (ATD95) were used. The L- and M-cone sensitivities of red–green defectives were either set to zero (cone-loss hypothesis) or replaced by that of a different cone-type (cone-replacement hypothesis), whereas for tritanopes the S-cone sensitivity was always assumed to be zero. The opponent mechanisms were either left unchanged or nulled in one or in all the opponent…

research product

Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity

Aim To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. Methods An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. Results The Sw was smaller …

research product

Spatio-temporal Contrast Sensitivity in the Cardinal Directions of the Colour Space. A Review

AbstractWe review the psychophysics of the spatio-temporal contrast sensitivity in the cardinal directions of the colour space and their correlation with those neural characteristics of the visual system that limit the ability to perform contrast detection or pattern-resolution tasks. We focus our attention particularly on the influence of luminance level, spatial extent and spatial location of the stimuli - factors that determine the characteristics of the physiological mechanisms underlying detection. Optical factors do obviously play a role, but we will refer to them only briefly. Contrast sensitivity measurements are often used in clinical practice as a method to detect, at their early …

research product

Patient-specific simulation of the intrastromal ring segment implantation in corneas with keratoconus

Purpose The purpose of this study was the simulation of the implantation of intrastromal corneal-ring segments for patients with keratoconus. The aim of the study was the prediction of the corneal curvature recovery after this intervention. Methods Seven patients with keratoconus diagnosed and treated by implantation of intrastromal corneal-ring segments were enrolled in the study. The 3D geometry of the cornea of each patient was obtained from its specific topography and a hyperelastic model was assumed to characterize its mechanical behavior. To simulate the intervention, the intrastromal corneal-ring segments were modeled and placed at the same location at which they were placed in the s…

research product

Evaluation of intraocular pressure and other biomechanical parameters to distinguish between subclinical keratoconus and healthy corneas

(1) Purpose: To assess the main corneal response differences between normal and subclinical keratoconus (SCKC) with a Corvis® ST device. (2) Material and Methods: We selected 183 eyes of normal patients, of a mean age of 33 ± 9 years and 16 eyes of patients with SCKC of a similar mean age. We measured best corrected visual acuity (BCVA) and corneal topography with a Pentacam HD device to select the SCKC group. Biomechanical measurements were performed using the Corvis® ST device. We carried out a non-parametric analysis of the data with SPSS software (Wilcoxon signed rank-test). (3) Results: We found statistically significant differences between the control and SCKC groups in some corneal b…

research product

Corresponding-pair procedure: a new approach to simulation of dichromatic color perception.

The dichromatic color appearance of a chromatic stimulus T can be described if a stimulus S is found that verifies that a normal observer experiences the same sensation viewing S as a dichromat viewing T. If dichromatic and normal versions of the same color vision model are available, S can be computed by applying the inverse of the normal model to the descriptors of T obtained with the dichromatic model. We give analytical form to this algorithm, which we call the corresponding-pair procedure. The analytical form highlights the requisites that a color vision model must verify for this procedure to be used. To show the capabilities of the method, we apply the algorithm to different color vi…

research product

A simple description of age-related changes in crystalline lens thickness.

Purpose An increase in lens thickness is often described as a linear function of age. However, contradictory opinions exist about whether the lens thickness continues to increase after 50 years of age. Differences in slope exist between this increase in younger and older people, but these findings are inconsistent with the linear behavior of an increase in the lens thickness throughout life. We investigated among different functions, including slope variation, which would be the best to show the relation between lens thickness and age. An available model portraying lens growth could be advantageous in many practical applications. The possibility of differences between sexes in lens thicknes…

research product

Visual fields in a chloroquine treatment

Purpose: In this study, we describe contrast sensitivity losses in the visual field of a patient affected by chloroquine toxicity, measured with stimuli favoring different visual mechanisms. We have compared these results with those of other, usual clinical tests. Methods: The vision of a patient who underwent ten years of chloroquine treatment was analyzed by a battery of clinical tests: visual acuity (VA), Amsler’s grid, Farnsworth–Munsell 100-hue test, spectral domain optical coherence tomography, multifocal electroretinogram (ERG), white-on-white and red-on-white Humphrey perimetries, chromatic and achromatic contrast sensitivity perimetry tests, and fluorescein angiography. Measurement…

research product

A rapid method for measuring intraocular lens power in vitro with a focimeter.

In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.

research product

Red-green vs. blue-yellow spatio-temporal contrast sensitivity across the visual field

We measured contrast sensitivity (CS) to sinusoidal spatio-temporal patterns isolating the red-green and blue-yellow mechanisms, at 21 locations in the visual field (including the fovea). These measurements complete the available data for the red-green mechanism at fovea and for both mechanisms outside fovea with non-stationary patterns. Chromatic detection surfaces are low-pass at fovea and CS decreases with eccentricity at a rate that depends on the spatial and temporal frequencies. Our results confirm that, in general, sensitivities decrease with eccentricity at different rates for stationary red-green and blue-yellow patterns at each point of the spatio-temporal domain and that the chro…

research product

Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study

Purpose. - To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. Methods. - All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. Results. - We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, an…

research product