0000000000116311
AUTHOR
Vantte Kilappa
Phased laser diode array permits selective excitation of ultrasonic guided waves in coated bone-mimicking tubes
This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2-3mm wall thickn…
Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study
Determination of cortical bone thickness is warranted, e.g., for assessing the level of endosteal resorption in osteoporosis or other bone pathologies. We have shown previously that the velocity of the fundamental antisymmetric (or flexural) guided wave, measured for bone phantoms and bones in vitro, correlates with the cortical thickness significantly better than those by other axial ultrasound methods. In addition, we have introduced an inversion scheme based on guided wave theory, group velocity filtering and 2-D fast Fourier transform, for determination of cortical thickness from the measured velocity of guided waves. In this study, the method was validated for tubular structures by usi…
Obstructing propagation of interfering modes improves detection of guided waves in coated bone models
Interference due to wave propagation in soft tissue that covers the bone is a major challenge to in vivo assessment of the fundamental flexural guided wave (FFGW) in bone. To improve signal-to-interference ratio (SIR) we propose to obstruct the propagation of interfering modes by locally deforming the coating by external mechanical compression. This approach was modeled by 2D finite-element transient domain (FEMTD) simulations in a fluid-coated (7 mm) solid plate (3 mm). The fluid layer mimics the soft tissue that covers the bone. A single emitter or a 6-element phased array excited ultrasound pulses at 50 kHz on the surface of the coating, and a receiver array was placed on the surface, 20…
Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius
Recent in vitro and simulation studies have shown that guided waves measured at low ultrasound frequencies (f=200 kHz) can characterize both material properties and geometry of the cortical bone wall. In particular, a method for an accurate cortical thickness estimation from ultrasound velocity data has been presented. The clinical application remains, however, a challenge as the impact of a layer of soft tissue on top of the bone is not yet well established, and this layer is expected to affect the dispersion and relative intensities of guided modes. The present study is focused on the theoretical modeling of the impact of an overlying soft tissue. A semianalytical method and finite-differ…
84 Enhanced Characterization of the Thickness and Bone Mineral Density of the Radius and Tibia by Low-Frequency Guided-Wave Ultrasound
Photo-acoustic phase-delayed excitation of guided waves in coated bone phantoms
Photo-acoustic skeletal quantitative ultrasound enables assessment of the fundamental flexural guided wave (FFGW) propagating in bone. This mode, consistent with the F(1,1) tube mode can now be measured through a coating of soft tissue. Interference due to ultrasound propagation in the soft tissue surrounding the bone is reduced by using phase-delayed ultrasound excitation. Photo-acoustic phase-delayed excitation was done on five axisymmetric bone phantoms (1-5 mm wall thickness), coated by a 5 mm thick soft-tissue mimicking layer. A fiber head comprising a linear array of four optical fibers (400 μm diameter), illuminated by pulsed laser diodes (905 nm wavelength) generated ultrasound. Thi…
Assessment of the fundamental flexural guided wave in cortical bone by an ultrasonic axial-transmission array transducer
Abstract The fundamental flexural guided wave (FFGW), as modeled, for example, by the A0 Lamb mode, is a clinically useful indicator of cortical bone thickness. In the work described in this article, we tested so-called multiridge-based analysis, based on the crazy climber algorithm and short-time Fourier transform, for assessment of the FFGW component recorded by a clinical array transducer featuring a limited number of elements. Methods included numerical finite-element simulations and experiments in bone phantoms and human radius specimens ( n = 41). The proposed approach enabled extraction of the FFGW component and determination of its group velocity. This group velocity was in good ag…
Ultrasound measurements in bone using an array transducer
Comparison of three ultrasonic axial transmission methods for bone assessment.
Abstract This study compared three approaches to bone assessment using ultrasonic axial transmission. In 41 fresh human radii, velocity of the first arriving signal was measured with a commercial device (Sunlight Omnisense ™ ) operating at 1.25 MHz, a prototype based on 1-MHz bidirectional axial transmission and a low-frequency (200 kHz) prototype, also measuring the velocity of a slower wave. Cortical and trabecular bone mineral density, cortical thickness and cross-sectional area were determined by peripheral quantitative computed tomography. Significant but modest correlation between velocities reflects differences in the nature of the propagating waves and methodological differences. Of…
Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.
Abstract Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the s…
Measuring guided waves in long bones: Modeling and experiments in free and immersed plates
Guided waves, consistent with the A0 Lamb mode, have previously been observed in bone phantoms and human long bones. Reported velocity measurements relied on line fitting of the observed wave fronts. Such an approach has limited ability to assess dispersion and is affected by interference by other wave modes. For a more robust identification of modes and determination of phase velocities, signal processing techniques using the fast Fourier transform (FFT) were investigated. The limitations of FFT because of spatial resolution were addressed to improve the precision of the measured modes. An inversion scheme was developed for determining the plate thickness from the measured velocity. Experi…
Tailoring the excitation of fundamental flexural guide waves in coated bone by phase-delayed array: Two-dimensional simulations
The fundamental flexural guided wave (FFGW) enables ultrasonic assessment of cortical bone thickness. In vivo, it is challenging to detect this mode, as its power ratio with respect to disturbing ultrasound is reduced by soft tissue covering the bone. A phase-delayed ultrasound source is proposed to tailor the FFGW excitation in order to improve its power ratio. This situation is analyzed by 2D finite-element simulations. The soft tissue coating (7-mm thick) was simulated as a fluid covering an elastic plate (bone, 2–6 mm thick). A six-element array of emitters on top of the coating was excited by 50-kHz tone bursts so that each emitter was appropriately delayed from the previous one. Respo…
Thickness sensitivity of ultrasound velocity in long bone phantoms
One approach to bone disease diagnosis such as osteoporosis is to measure the velocity of ultrasound propagating axially along long bones. In this study, the variation in velocity as a function of radial position was assessed using two polyvinyl chloride (PVC) bone phantoms with cross-sectional geometry similar to the human tibia but differing in medullary cavity diameter. Two ultrasonometers were used: these were a commercial device operating at a relatively high frequency (HF) of 1.25 MHz and a prototype low frequency (LF) device operating at approximately 200 kHz. The LF measurements showed a larger variation with radial position, with changes in velocity of up to 20% occurring around th…