0000000000116312

AUTHOR

Edward Hæggström

showing 9 related works from this author

Phased laser diode array permits selective excitation of ultrasonic guided waves in coated bone-mimicking tubes

2017

This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2-3mm wall thickn…

Materials scienceOpacityultrasonicsGeneral Physics and Astronomy02 engineering and technologyengineering.material01 natural sciences114 Physical scienceslaw.inventionOpticsCoatinglaw0103 physical sciencespolymeeritpolymersacoustical properties010302 applied physicsta114Laser diodebusiness.industryUltrasoundwaveguides021001 nanoscience & nanotechnologyPhotoexcitationlaseritengineeringUltrasonic sensor0210 nano-technologybusinesslasersExcitationEnergy (signal processing)
researchProduct

Obstructing propagation of interfering modes improves detection of guided waves in coated bone models

2014

Interference due to wave propagation in soft tissue that covers the bone is a major challenge to in vivo assessment of the fundamental flexural guided wave (FFGW) in bone. To improve signal-to-interference ratio (SIR) we propose to obstruct the propagation of interfering modes by locally deforming the coating by external mechanical compression. This approach was modeled by 2D finite-element transient domain (FEMTD) simulations in a fluid-coated (7 mm) solid plate (3 mm). The fluid layer mimics the soft tissue that covers the bone. A single emitter or a 6-element phased array excited ultrasound pulses at 50 kHz on the surface of the coating, and a receiver array was placed on the surface, 20…

Guided wave testingMaterials scienceta114Wave propagationPhased arraybusiness.industryWave packetDeformation (meteorology)engineering.materialOpticsInterference (communication)CoatingengineeringbusinessCommon emitterta217
researchProduct

Photo-acoustic phase-delayed excitation of guided waves in coated bone phantoms

2013

Photo-acoustic skeletal quantitative ultrasound enables assessment of the fundamental flexural guided wave (FFGW) propagating in bone. This mode, consistent with the F(1,1) tube mode can now be measured through a coating of soft tissue. Interference due to ultrasound propagation in the soft tissue surrounding the bone is reduced by using phase-delayed ultrasound excitation. Photo-acoustic phase-delayed excitation was done on five axisymmetric bone phantoms (1-5 mm wall thickness), coated by a 5 mm thick soft-tissue mimicking layer. A fiber head comprising a linear array of four optical fibers (400 μm diameter), illuminated by pulsed laser diodes (905 nm wavelength) generated ultrasound. Thi…

Photoacoustic effectOptical fiberMaterials scienceGuided wave testingta114business.industryUltrasoundPhase (waves)01 natural scienceslaw.invention030507 speech-language pathology & audiology03 medical and health sciencesWavelengthTransducerOpticslaw0103 physical sciences0305 other medical sciencebusiness010301 acousticsGroup delay and phase delay
researchProduct

Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.

2013

Abstract Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the s…

Materials scienceAcoustics and UltrasonicsBiophysics02 engineering and technology01 natural sciencesSensitivity and SpecificityImaging phantomBone and Bones010309 opticsOpticsLamb wavesFlexural strengthCoated Materials BiocompatibleBone Density0103 physical sciencesmedicineHumansRadiology Nuclear Medicine and imagingGuided wave testingRadiological and Ultrasound Technologyta114business.industryPhantoms ImagingLasersUltrasoundReproducibility of ResultsEquipment Design021001 nanoscience & nanotechnologyEquipment Failure Analysismedicine.anatomical_structureSoundAcoustic StimulationElasticity Imaging TechniquesUltrasonic sensorCortical bonePhase velocity0210 nano-technologybusinessPhotic StimulationDensitometryUltrasound in medicinebiology
researchProduct

Evaluating pulp stiffness from fibre bundles by ultrasound

2012

A non-destructive ultrasonic tester was developed to measure the stiffness of pulp bundles. The mechanical properties of pulp are important when estimating the behaviour of paper under stress. Currently available pulp tests are tedious and alter the fibres structurally and mechanically. The developed tester employs (933 ± 15) kHz tweezer-like ultrasonic transducers and time-of-flight measurement through (9.0 ± 2.5) mm long and (0.8 ± 0.1) mm thick fibre bundles kept at (19.1 ± 0.4) °C and (62 ± 1)% RH. We determined the stiffness of soft wood pulps produced by three kraft pulping modifications: standard kraft pulp, (5.2 ± 0.4) GPa, prehydrolysis kraft pulp, (4.3 ± 0.4) GPa, and alkali extra…

SoftwoodMaterials science0211 other engineering and technologiesmacromolecular substances02 engineering and technologyengineering.material01 natural scienceschemistry.chemical_compoundstomatognathic system0103 physical sciencesmedicineHemicelluloseComposite materialCellulose010301 acousticsInstrumentationEngineering (miscellaneous)021102 mining & metallurgyApplied MathematicsPapermakingPulp (paper)Stiffnessstomatognathic diseaseschemistryKraft processengineeringUltrasonic sensormedicine.symptomMeasurement Science and Technology
researchProduct

Photo-acoustic excitation and detection of guided ultrasonic waves in bone samples covered by a soft coating layer

2012

Photo-acoustic (PA) excitation was combined with skeletal quantitative ultrasound (QUS) for multi-mode ultrasonic assessment of human long bones. This approach permits tailoring of the ultrasonic excitation and detection so as to efficiently detect the fundamental flexural guided wave (FFGW) through a coating of soft tissue. FFGW is a clinically relevant indicator of cortical thickness. An OPO laser with tunable optical wavelength, was used to excite a photo-acoustic source in the shaft of a porcine femur. Ultrasonic signals were detected by a piezoelectric transducer, scanning along the long axis of the bone, 20-50 mm away from the source. Five femurs were measured without and with a soft …

Materials scienceengineering.material01 natural sciences030218 nuclear medicine & medical imaginglaw.invention010309 optics03 medical and health sciences0302 clinical medicineOpticsCoatinglaw0103 physical sciencesmedicineGuided wave testingta114business.industryWavelengthTransducermedicine.anatomical_structureengineeringCortical boneUltrasonic sensorsense organsPhase velocitybusinessWaveguideSPIE Proceedings
researchProduct

E-sail test payload of the ESTCube-1 nanosatellite

2014

The scientific mission of ESTCube-1, launched in May 2013, is to measure the electric solar wind sail (E-sail) force in orbit. The experiment is planned to push forward the development of the E-sail, a propulsion method recently invented at the Finnish Meteorological Institute. The E-sail is based on extracting momentum from the solar wind plasma flow by using long thin electrically charged tethers. ESTCube-1 is equipped with one such tether, together with hardware capable of deploying and charging it. At the orbital altitude of ESTCube-1 (660–680 km) there is no solar wind present. Instead, ESTCube-1 shall observe the interaction between the charged tether and the ionospheric plasma. The E…

Physicsta114Payloadbusiness.industryGeneral EngineeringPropulsionlaw.inventionSlip ringSolar windlawElectric sailAerospace engineeringIonosphereSpace researchbusinessVoltageProceedings of the Estonian Academy of Sciences
researchProduct

Selective Excitation of Guided Waves into Bone Phantoms by a Time-Delayed Laser Diode Array

2012

We excite selectively the Ao and So plate mode into an acrylic bone phantom using a laser diode array. This is done by controlling the time delay between the signals driving the array elements. Selective mode generation is important because it can potentially increase the sensitivity of in vivo osteoporosis screening.

Photoacoustic effect0303 health sciencesMaterials scienceLaser diodebusiness.industry030209 endocrinology & metabolismSelective excitationImaging phantomlaw.inventionOsteoporosis screeningUltrasonic imaging03 medical and health sciences0302 clinical medicineTime delayedOptics030301 anatomy & morphologylawbusinessSensitivity (electronics)2012 Symposium on Photonics and Optoelectronics
researchProduct

Tailoring the excitation of fundamental flexural guide waves in coated bone by phase-delayed array: Two-dimensional simulations

2015

The fundamental flexural guided wave (FFGW) enables ultrasonic assessment of cortical bone thickness. In vivo, it is challenging to detect this mode, as its power ratio with respect to disturbing ultrasound is reduced by soft tissue covering the bone. A phase-delayed ultrasound source is proposed to tailor the FFGW excitation in order to improve its power ratio. This situation is analyzed by 2D finite-element simulations. The soft tissue coating (7-mm thick) was simulated as a fluid covering an elastic plate (bone, 2–6 mm thick). A six-element array of emitters on top of the coating was excited by 50-kHz tone bursts so that each emitter was appropriately delayed from the previous one. Respo…

fundamental flexural guided wavesGuided wave testingMaterials scienceAcoustics and Ultrasonicsta114business.industryultrasoundPhase (waves)engineering.materialmedicine.anatomical_structureOpticsLamb wavesArts and Humanities (miscellaneous)Coatingcortical bone thicknessmedicineengineeringCortical boneUltrasonic sensorbusinessExcitationCommon emitterta217Journal of the Acoustical Society of America
researchProduct