0000000000118671

AUTHOR

Yan L

showing 5 related works from this author

First Measurement of the Absolute Branching Fraction of Λ→pμ−ν¯μ

2021

The absolute branching fraction of Λ→pμ−ν¯μ is reported for the first time based on an e+e− annihilation sample of 10×109 J/ψ events collected with the BESIII detector at s=3.097 GeV. The branching fraction is determined to be B(Λ→pμ−ν¯μ)=[1.48±0.21(stat)±0.08(syst)]×10−4, which is improved by about 30% in precision over the previous indirect measurements. Combining this result with the world average of B(Λ→pe−ν¯e), we obtain the ratio {[Γ(Λ→pμ−ν¯μ)]/[Γ(Λ→pe−ν¯e)]} to be 0.178±0.028, which agrees with the standard model prediction assuming lepton flavor universality. The asymmetry of the branching fractions of Λ→pμ−ν¯μ and Λ¯→p¯μ+νμ is also determined, and no evidence for CP violation is fo…

PhysicsMeasurementAnnihilationBranching010308 nuclear & particles physicsBranching fractionmedia_common.quotation_subjectGeneral Physics and AstronomyAbsoluteTime based01 natural sciencesAsymmetryNOStandard ModelSubatomär fysikSubatomic Physics0103 physical sciencesCP violationAtomic physics010306 general physicsLeptonmedia_commonPhysical Review Letters
researchProduct

Complete Measurement of the Λ Electromagnetic Form Factors.

2019

The exclusive process e+e−→ΛΛ¯, with Λ→pπ− and Λ¯→p¯π+, has been studied at s=2.396 GeV for measurement of the timelike Λ electric and magnetic form factors, GE and GM. A data sample, corresponding to an integrated luminosity of 66.9 pb−1, was collected with the BESIII detector for this purpose. A multidimensional analysis with a complete decomposition of the spin structure of the reaction enables a determination of the modulus of the ratio R=|GE/GM| and, for the first time for any baryon, the relative phase ΔΦ=ΦE−ΦM. The resulting values are R=0.96±0.14(stat)±0.02(syst) and ΔΦ=37°±12°(stat)±6°(syst), respectively. These are obtained using the recently established and most precise value of …

Multi-dimensional analysisElectron–positron annihilationRelative phaseHadronAnalytical chemistryGeneral Physics and AstronomyHadronsOBSERVABLESLambdaBaryon01 natural sciencesArticleNOHigh Energy Physics - ExperimentSubatomär fysikGermanium compoundsElectromagnetic form factorsSubatomic Physics0103 physical sciencesMagnetic form factorTwo-photon exchangePiddc:530010306 general physicsAsymmetry parameterProton Scattering; Nucleons; HydrogenPhysicsIntegrated luminosityDecompositionPhysicsHigh Energy Physics::PhenomenologyApproximation theoryPhysics multidisciplinaryPhotonHigh Energy Physics - Experiment; High Energy Physics - ExperimentBaryonLuminanceSpin structuresHigh Energy Physics::ExperimentMagnetic form factorMulti dimensional analysisBar (unit)Physical review letters
researchProduct

A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries

2018

© 2018 SPIE. In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 ± 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with in…

Materials scienceElectronic sphygmomanometerIdentification errorMulti wavelengthPeripheralInflatableBlood pressuremedicine.arteryCuffSettore ING-IND/12 - Misure Meccaniche E TermichemedicineRadial arteryblood pressure Multi-Wavelength opto-electronic patch sensor (OEPS) photopletismgraphy PPG systolic blood pressure wearable sensorBiomedical engineeringDesign and Quality for Biomedical Technologies XI
researchProduct

Liraglutide and Renal Outcomes in Type 2 Diabetes.

2017

BACKGROUND: In a randomized, controlled trial that compared liraglutide, a glucagon-like peptide 1 analogue, with placebo in patients with type 2 diabetes and high cardiovascular risk who were receiving usual care, we found that liraglutide resulted in lower risks of the primary end point (nonfatal myocardial infarction, nonfatal stroke, or death from cardiovascular causes) and death. However, the long-term effects of liraglutide on renal outcomes in patients with type 2 diabetes are unknown. METHODS: We report the prespecified secondary renal outcomes of that randomized, controlled trial in which patients were assigned to receive liraglutide or placebo. The secondary renal outcome was a co…

MaleSettore MED/09 - Medicina InternaAcute Kidney Injury; Aged; Albuminuria; Creatinine; Diabetes Mellitus Type 2; Diabetic Nephropathies; Double-Blind Method; Female; Follow-Up Studies; Glomerular Filtration Rate; Glucagon-Like Peptide 1; Humans; Hypoglycemic Agents; Intention to Treat Analysis; Kidney Failure Chronic; Liraglutide; Male; Middle AgedType 2 diabetes030204 cardiovascular system & hematologyurologic and male genital diseasesGLOMERULAR-FILTRATION-RATEKIDNEY-FUNCTIONDISEASElaw.inventionKidney Failurechemistry.chemical_compound0302 clinical medicineRandomized controlled trialGlucagon-Like Peptide 1lawMedicineDiabetic NephropathiesHypoglycemic Agents.Settore MED/49 - Scienze Tecniche Dietetiche ApplicateChronicRISKKidneyAcute kidney injury11 Medical And Health SciencesGeneral MedicineAcute Kidney InjuryMiddle AgedIntention to Treat Analysismedicine.anatomical_structureCreatinineTRIALFemaleliraglutide randomized controlled trial type 2 diabetes renal outcomesLife Sciences & BiomedicineType 2Glomerular Filtration Ratemedicine.drugmedicine.medical_specialtyRenal function030209 endocrinology & metabolismCARDIOVASCULAR OUTCOMESFollow-Up Studie03 medical and health sciencesMedicine General & InternalDouble-Blind MethodGeneral & Internal MedicineDiabetes mellitusInternal medicineDiabetes MellitusAlbuminuriaHumansHypoglycemic AgentsIntensive care medicineAgedCreatinineScience & Technologybusiness.industryLiraglutideMORTALITYLiraglutidemedicine.diseaseINTENSIVE GLUCOSE CONTROLINDIVIDUALSDiabetes Mellitus Type 2chemistryDiabetic NephropathieKidney Failure ChronicLEADER Steering Committee and InvestigatorsbusinessFollow-Up Studies
researchProduct

Evidence for the direct two-photon transition from ψ(3686) to J/ψ.

2012

The two-photon transition ψ(3686)→γγJ/ψ is studied in a sample of 1.06×10(8) ψ(3686) decays collected by the BESIII detector. The branching fraction is measured to be (3.1±0.6(stat)(-1.0)(+0.8)(syst))×10(-4) using J/ψ→e(+)e(-) and J/ψ→μ(+)μ(-) decays, and its upper limit is estimated to be 4.5×10(-4) at the 90% confidence level. This work represents the first measurement of a two-photon transition among charmonium states. The orientation of the ψ(3686) decay plane and the J/ψ polarization in this decay are also studied. In addition, the product branching fractions of sequential E1 transitions ψ(3686)→γχ(cJ) and χ(cJ)→γJ/ψ(J=0,1,2) are reported.

PhysicsParticle physicsBranching fractionElectron–positron annihilationGeneral Physics and AstronomyPhysical review letters
researchProduct