0000000000147204
AUTHOR
Patricia Cava-montesinos
Room temperature acid sonication ICP-MS multielemental analysis of milk
Abstract Room temperature acid sonication of milk samples is proposed as a fast alternative methodology for the determination of the total content of 45 elements (Li, Al, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Mo, Ag, Cd, In, Sn, U, Sb, Te, Cs, Ba, Hg, Pb, Bi, Th, La, Ce, Pr, Nd, Sm, Eu, Gd, Dy, Ho, Er, Tm, Yb, Lu, Hf and Ta) in milk by inductively coupled plasma mass spectrometry (ICP-MS). The aforementioned procedure involves a 10 min sample pre-treatment. Measurements were made in quantitative and semiquantitative (Totalquant ® ) modes of analysis using Rh as internal standard and Be, Ge, Tb and Re for internal calibration of the equipment in the semiquantitative mode. The…
Non-chromatographic speciation analysis of arsenic and antimony in milk hydride generation atomic fluorescence spectrometry
Abstract A rapid, high sensitivity method has been developed for the determination of As(III), As(V), Sb(III) and Sb(V) in milk samples by using hydride generation atomic fluorescence spectrometry. The method is based on the leaching of As and Sb from milk through the sonication of samples with aqua regia followed by direct determination of the corresponding hydrides both before and after reduction with KI. It was confirmed by recovery experiments on spiked commercially available samples that neither the reduced nor the oxidized forms of the elements under study or mixtures of the two oxidation states were modified by the room temperature sample treatment with aqua regia. The methodologies …
On-line speciation of mercury in fish by cold vapour atomic fluorescence through ultrasound-assisted extraction
A fully mechanized procedure has been developed for the speciation of mercury in fish samples by using cold vapour atomic fluorescence spectrometry (CV-AFS). Sample slurries in an acid mixture in the presence of a surfactant and with traces of K2Cr2O7, were injected into a flow system, sonicated and merged with 1 ml of an oxidant mixture of KBr/KBrO3 heated at 50 °C in a water bath and total Hg determined by CV-AFS. Sonicated sample slurries were also measured, in the absence of KBr/KBrO3, in order to obtain a second series of data which could be employed to establish the concentrations of free Hg(II). Different compositions of the acidic extractant solutions were evaluated by mixing HCl, H…
Speciation of selenium and tellurium in milk by hydride generation atomic fluorescence spectrometry
A simple, fast and highly sensitive method has been developed for the differentiation of Se and Te into their (IV) and (VI) oxidation states in milk samples by HG-AFS. This procedure involves a previous leaching of milk slurries by sonication with aqua regia for 10 min. Se(IV) and Te(IV) were determined by analysis of the samples without a pre-reduction step; being total Se and Te determined after reduction with KBr. The method provides limit of detection values (LOD) of 0.012 and 0.023 ng ml−1 for Se(IV) and Te(IV) respectively. Average relative standard deviation values of 10.5%, 3.9%, 12% and 12.5% were found for the determination of Se(IV), Se(VI), Te(IV) and Te(VI) in milk samples cont…
Determination of As, Sb, Se, Te and Bi in milk by slurry sampling hydride generation atomic fluorescence spectrometry
A simple and fast analytical procedure has been developed for the determination of As, Sb, Se, Te and Bi in milk samples by hydride generation atomic fluorescence spectrometry (HG-AFS). Samples were treated with aqua regia for 10min in an ultrasound water bath and pre-reduced with KBr for total Se and Te determination or with KI and ascorbic acid for total As and Sb, the determination of Bi being possible in all with or without pre-reduction. Slurries of samples, in the presence of antifoam A, were treated with NaBH(4) in HCl medium to obtain the corresponding hydrides, and AFS measurements were processed in front of external calibrations prepared and measured in the same way as samples. Re…
Fast extraction methodologies for the determination of toxic arsenic in meat
Summary A nonchromatographic analytical procedure has been developed for the determination of arsenic in meat samples including the major toxic arsenic species arsenite, arsenate, monomethylarsonic acid (MMA) and dimetylarsinic acid (DMA). The method is based on the extraction of arsenic species in mild conditions, selective trivalent hydride formation and final determination by hydride generation atomic fluorescence spectroscopy (HG-AFS). Different extractant agents and two different procedures, microwave-assisted extraction (MAE) and ultrasound assisted extraction at room temperature, were evaluated for As species extraction. The method provided a limit of detection of 0.013 ng mL−1 and a…
Determination of arsenic and antimony in milk by hydride generation atomic fluorescence spectrometry
Abstract A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow m…
Multicommutation as an environmentally friendly analytical tool in the hydride generation atomic fluorescence determination of tellurium in milk.
The aim of this study is to show the advantages of the emerging multicommutation methodology based on the use of solenoid valves for Te determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS). The delivery of a series of alternating sequential insertions of small volumes of samples and reagents gives rise to new hydrodynamic processes and exciting analytical potentials by controlling the time of flow through the on/off-switched solenoid valves. This drastically reduces the reagent consumption by a factor of 4 and the generation of effluents (590 mL h(-1) instead of 750 mL h(-1) generated by the continuous-mode measurement) and also provides an improvement in th…
Hydride generation atomic fluorescence spectrometric determination of ultratraces of selenium and tellurium in cow milk
Abstract A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.
Non-chromatographic speciation of toxic arsenic in fish
Abstract A rapid, sensitive and economic method has been developed for the direct determination of toxic species of arsenic present in fish and mussel samples. As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) were determined by hydride generation–atomic fluorescence spectrometry using a series of proportional equations without the need of a chromatographic previous separation. The method is based on the extraction of arsenic species from fish through sonication with HNO3 3 mol l−1 and 0.1% (m/v) Triton and washing of the solid phase with 0.1% (m/v) EDTA, followed by direct measurement of the corresponding hydrides in four different experimental conditions. The li…
1,3-Oxazin-2-ones vs tetrahydrofurans by iodocyclisation of 2-alkoxycarbonylamino-3-alken-1-ols
Abstract Iodocyclisation of primary homoallylic alcohols 2a – d , containing either a 2- t -butoxy- or a benzyloxycarbonylamino group, was studied, in order to establish the nucleophilic group involved in cyclofunctionalisation. In fact, the N - t -Boc derivative 2a gave the oxazinone 3 , exclusively, whereas starting from the N -Cbz derivative 2b a diastereomeric mixture of substituted tetrahydrofurans 4 and 5 resulted in ratios depending upon the reaction conditions. These results were rationalised by means of computational methods. On the contrary, migration of both the t -butyl or benzyl group to the hydroxy group was observed when both 2c and 2d underwent cyclisation to give the corres…
Cold vapour atomic fluorescence determination of mercury in milk by slurry sampling using multicommutation
Abstract A highly sensitive mechanized method has been developed for the determination of mercury in milk by atomic fluorescence spectrometry (AFS). Samples were sonicated for 10 min in an ultrasound water bath in the presence of 8% (v/v) aqua regia, 2% (v/v) antifoam A and 1% (m/v) hydroxilamine hydrochloride, and after that, they were treated with 8 mmol l −1 KBr and 1.6 mmol l −1 KBrO 3 in an hydrochloric medium. Atomic fluorescence measurements were made by multicommutation, which provides a fast alternative in quality control analysis, due to the easy treatment of a large number of samples (approximately 70 h −1 ), and is an environmentally friendly procedure, which involves a waste ge…
Determination of ultratrace bismuth in milk samples by atomic fluorescence spectrometry.
Abstract A sensitive procedure was developed for determination of bismuth (Bi) in milk samples by hydride generation atomic fluorescence spectrometry (HG–AFS) after microwave-assisted sample digestion with HNO3 and H2O2. The method provides a sensitivity of 1832 fluorescence units (ng/mL) with a detection limit of 0.01 ng/mL, which corresponds to 20 pg absolute limit of detection, equivalent to 0.50 ng/g in the original sample. Application of the methodology to cow milk samples from the Spanish market showed the presence of Bi at a concentration of 11.8–28.8 ng/g, which compared well with data obtained after dry ashing of samples and with data obtained by inductively coupled plasma–mass spe…