0000000000147985

AUTHOR

Luis Caballero

showing 17 related works from this author

First Compton imaging tests with i-TED

2019

The objective of this work is to demonstrate the Compton imaging capabilities of a novel gamma-ray Total-Energy Detector called i-TED. The latter is intended for neutron-capture cross-sections measurements of astrophysical interest, thereby enhancing detection sensitivity by means of the simultaneous combination of Time-of-Flight with Compton-imaging techniques. The developed i-TED demonstrator comprises five position-sensitive radiation detection modules of high energy resolution, which feature an overall position-sensitive field-of-view of 125 cm2, and thus a high efficiency. Each detector module is based on 50x50 mm2 large LaCl 3 (Ce) monolithic crystals optically coupled to 8x8 pixels s…

PhysicsPixelPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industryDetectorResolution (electron density)01 natural sciencesParticle detector030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineSilicon photomultiplierOptics0103 physical sciencesAngular resolutionbusinessImage resolutionEnergy (signal processing)2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
researchProduct

Echocardiographic reference ranges for normal left ventricular 2D strain: results from the EACVI NORRE study

2017

International audience; Aims - To obtain the normal ranges for 2D echocardiographic (2DE) measurements of left ventricular (LV) strain from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 549 (mean age: 45.6 ± 13.3 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. 2DE data sets have been analysed with a vendor-independent software package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire the data sets. The lowest expected values of LV strains and twist calculated as ± 1.96 standard deviations from the mean…

MaleLongitudinal straindeformation imaging[SDV]Life Sciences [q-bio]Sex Factor030204 cardiovascular system & hematologyStandard deviationVentricular Function LeftHeart Ventricle2D echocardiography0302 clinical medicineReference ValuesNuclear Medicine and ImagingImage Processing Computer-AssistedMedicineCircumferential strainAge FactorReference Value030212 general & internal medicineMultivariate Analysi2D echocardiography; Adult echocardiography; Deformation imaging; Reference values; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular MedicineObserver VariationStrain (chemistry)Age FactorsGeneral MedicineMiddle AgedHealthy VolunteerHealthy VolunteersEuropeHomogeneousEchocardiographyRadiology Nuclear Medicine and imagingCardiologyLinear ModelFemaleRadiologyCardiology and Cardiovascular MedicineRadial stressHumanAdultmedicine.medical_specialtyadult echocardiographyHeart Ventricles03 medical and health sciencesSex FactorsInternal medicineHumansRadiology Nuclear Medicine and imaging2d strainbusiness.industryMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREReference valuesMultivariate AnalysisLinear Modelsbusiness
researchProduct

Echocardiographic reference ranges for normal cardiac Doppler data: results from the NORRE Study

2015

International audience; AIMS: Reference values for Doppler parameters according to age and gender are recommended for the assessment of heart physiology, specifically for left ventricular (LV) diastolic function. In this study, we report normal reference ranges for Doppler parameters obtained in a large group of healthy volunteers. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following Doppler acquisition and measurement protocols approved by the European Association of Cardiovascular Imaging. METHODS AND RESULTS: A total of 449 (mean age: 45.8 ± 13.7 years) healthy volunteers (198 men and 251 women) were enrolled at the collaborating institutions…

MaleAgingLeft030204 cardiovascular system & hematologyDoppler echocardiographyVentricular Function LeftNORRE StudyCohort Studies0302 clinical medicineDiastoleReference ValuesNuclear Medicine and ImagingVentricular Function030212 general & internal medicineDoppler echocardiography; NORRE Study; reference values; systolic and diastolic function; Adult; Age Factors; Aged; Aging; Cohort Studies; Diastole; Echocardiography Doppler; Europe; Female; Healthy Volunteers; Heart Ventricles; Humans; Male; Middle Aged; Reference Values; Sex Factors; Systole; Ventricular Function Left; Young Adult; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicinesystolic and diastolic functionmedicine.diagnostic_testDopplerAge FactorsGeneral MedicineMiddle AgedEchocardiography DopplerHealthy VolunteersCardiovascular physiologyEuropemedicine.anatomical_structureEchocardiographyCardiologysymbolsFemale[SDV.IB]Life Sciences [q-bio]/BioengineeringRadiologyCardiology and Cardiovascular MedicineDoppler effectCohort studyAdultmedicine.medical_specialtySystoleHeart VentriclesDiastole03 medical and health sciencessymbols.namesakeYoung AdultSex FactorsInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingSystoleAgedbusiness.industryreference valueDoppler echocardiographyVentricleReference valuesbusiness
researchProduct

Echocardiographic reference ranges for normal cardiac chamber size: Results from the NORRE study

2014

AimsAvailability of normative reference values for cardiac chamber quantitation is a prerequisite for accurate clinical application of echocardiography. In this study, we report normal reference ranges for cardiac chambers size obtained in a large group of healthy volunteers accounting for gender and age. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following chamber quantitation protocols approved by the European Association of Cardiovascular Imaging.MethodsA total of 734 (mean age: 45.8 ± 13.3 years) healthy volunteers (320 men and 414 women) were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORR…

MaleLower blood pressureSex FactorHeart VentricleCohort StudiesChamber size and function; Reference values; Two-dimensional echocardiography; Cardiology and Cardiovascular Medicine; Radiology Nuclear Medicine and Imaging; Medicine (all)Nuclear Medicine and ImagingAge FactorReference ValueYoung adultBody surface areaObserver VariationMedicine (all)Age FactorsGeneral MedicineStroke volumeMiddle AgedEchocardiographyCardiologyFemaleCardiology and Cardiovascular MedicineRadiologyHumanCohort studyAdultmedicine.medical_specialtyHeart VentriclesReproducibility of ResultChamber size and functionRisk AssessmentReference valuesYoung AdultSex FactorsTwo-dimensional echocardiographyInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingHeart AtriaAgedbusiness.industryReproducibility of ResultsMean ageStroke VolumeMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREOriginal ArticlesCardiac chamberReference valuesCohort Studiebusiness
researchProduct

Beta decay studies with the total absorption technique: past, present and future

2005

Measurements of beta decay reduced transition probabilities are particularly relevant in nuclei far from the stability line. It has been demonstrated that a proper measurement of this quantity requires the use of the total absorption technique, which has become a reliable tool in recent years, thanks to the increased efficiency of the associated spectrometers and the development of new analysis techniques. In this paper, we present a brief history of the past and present use of these detectors and how they might be developed in the future.

Nuclear physicsPhysicsNuclear and High Energy PhysicsSpectrometerAbsorption (electromagnetic radiation)Stability (probability)Beta decayJournal of Physics G: Nuclear and Particle Physics
researchProduct

Nucleon transfer via (d,p) using TIARA with a24Ne radioactive beam

2005

NESTER; The first physics results measured using the TIARA array are reported. The reaction $^{24}$Ne(d,p)$^{25}$Ne has been studied in inverse kinematics with a radioactive beam of $^(24)$Ne provided by SPIRAL at GANIL. TIARA is very compact with a high geometrical coverage for charged particles, and is designed specifically for the study of transfer reactions in inverse kinematics, with radioactive beams. From the (d,p) differential cross sections, the ground state of $^{25}$Ne is assigned to have $J^\pi$ = $1/2^+$ and the lowest states with $J^\pi$ = $5/2^+$ and $3/2^+$ are tentatively identified at excitation energies of 1.70 and 2.05 (±0.05) MeV, respectively. Coincident gamma-ray data…

PhysicsNuclear and High Energy PhysicsSpectrometer010308 nuclear & particles physicsParity (physics)[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesCharged particleNuclear physicsCoincidentExcited state0103 physical sciencesAtomic physics010306 general physicsNucleonGround stateExcitationJournal of Physics G: Nuclear and Particle Physics
researchProduct

Deformation of Sr and Rb isotopes close to theN=Zline viaβ-decay studies using the total absorption technique

2013

A study of the Gamow-Teller strength distributions $B$(GT) in the beta decay of ${}^{78}$Sr and ${}^{76,78}$Rb has been made using a total absorption spectrometer (TAS). Following the success in deducing the sign of the deformation for ${}^{76}$Sr, a similar approach is adopted for ${}^{78}$Sr based on a comparison of the measured $B$(GT) with quasiparticle random-phase approximation calculations. This work confirms its previously expected prolate deformation in the ground state. Conclusions about the structure of the odd-odd ${}^{76,78}$Rb isotopes have been drawn based on their measured $B$(GT) distributions.

PhysicsNuclear and High Energy PhysicsIsotopeQuasiparticleProlate spheroidAbsorption (logic)Deformation (meteorology)Atomic physicsGround stateBeta decayLine (formation)Physical Review C
researchProduct

Two-phonon octupole excitation inGd146

2010

Based on experimental evidence from the $^{144}\mathrm{Sm}$($\ensuremath{\alpha},2n$) reaction, the $3484.7$-keV ${6}^{+}$ state in $^{146}\mathrm{Gd}$ is identified as the highest-spin member of the ${3}^{\ensuremath{-}}\ensuremath{\bigotimes}{3}^{\ensuremath{-}}$ two-phonon octupole quartet. A previously unknown $\ensuremath{\gamma}$ line of $1905.8$ keV and $E3$ character feeding the ${3}^{\ensuremath{-}}$ octupole state has been observed. These results represent the first observation of a ${6}^{+}\ensuremath{\rightarrow}{3}^{\ensuremath{-}}\ensuremath{\rightarrow}{0}^{+}$ cascade of two $E3$ transitions in an even-even nucleus and provide strong support for the interpretation of the ${6…

Nuclear reactionRare earth nucleiPhysicsNuclear and High Energy PhysicsParticle propertiesPhononNeutron emissionState (functional analysis)Atomic physicsQuasi particlesExcitationPhysical Review C
researchProduct

Mass Measurements with the CSS2 and CIME cyclotrons at GANIL

2005

Commune avec ACEN; This paper presents two original direct mass-measurement techniques developed at GANIL using the CSS2 and CIME cyclotrons as high-resolution mass spectrometers. The mass measurement with the CSS2 cyclotron is based on a time-of-flight method along the spiral trajectory of the ions inside the cyclotron. The atomic mass excesses of 68Se and 80Y recently measured with this technique are -53.958(246) MeV and -60.971(180) MeV, respectively. The new mass-measurement technique with the CIME cyclotron is based on the sweep of the acceleration radio-frequency of the cyclotron. Tests with stable beams have been performed in order to study the accuracy of this new mass-measurement m…

Mass numberChemistryCyclotron020206 networking & telecommunicationsParticle accelerator02 engineering and technologyrp-process[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryAtomic masslaw.inventionIonNuclear physicsAccelerationlaw29.20.Hm 29.30.-h 21.10.Dr 27.50.+e0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processing
researchProduct

3D echocardiographic reference ranges for normal left ventricular volumes and strain: results from the EACVI NORRE study

2017

International audience; Aim: To obtain the normal ranges for 3D echocardiography (3DE) measurement of left ventricular (LV) volumes, function, and strain from a large group of healthy volunteers. Methods and results: A total of 440 (mean age: 45 ± 13 years) out of the 734 healthy subjects enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study had good-quality 3DE data sets that have been analysed with a vendor-independent software package allowing homogeneous measurements regardless of the echocardiographic machine used to acquire the data sets. Upper limits of LV end-diastolic and end-systolic volumes were larger in men (97 and 42 mL/m2)…

AdultMalemedicine.medical_specialtyLongitudinal strainadult echocardiographydeformation imagingHeart VentriclesCardiac VolumeDiastoleEchocardiography Three-Dimensional030204 cardiovascular system & hematologyVentricular Function LeftHeart VentricleReference values03 medical and health sciencesYoung Adultleft ventricular function0302 clinical medicineInternal medicineHealthy volunteersthree-dimensional echocardiographyMedicineCircumferential strainHumansRadiology Nuclear Medicine and imagingReference Value030212 general & internal medicineSystoleAgedEjection fractionStrain (chemistry)business.industryGeneral MedicineMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREMiddle AgedHealthy VolunteerHealthy Volunteers3. Good healthRadiology Nuclear Medicine and imagingReference valuesCardiologyFemale[SDV.IB]Life Sciences [q-bio]/BioengineeringbusinessCardiology and Cardiovascular MedicineHuman
researchProduct

Reactor Decay Heat inPu239: Solving theγDiscrepancy in the 4–3000-s Cooling Period

2010

The {beta} feeding probability of {sup 102,104,105,106,107}Tc, {sup 105}Mo, and {sup 101}Nb nuclei, which are important contributors to the decay heat in nuclear reactors, has been measured using the total absorption technique. We have coupled for the first time a total absorption spectrometer to a Penning trap in order to obtain sources of very high isobaric purity. Our results solve a significant part of a long-standing discrepancy in the {gamma} component of the decay heat for {sup 239}Pu in the 4-3000 s range.

Nuclear physicsPhysicsDouble beta decayGeneral Physics and AstronomyOrder (ring theory)Isobaric processAbsorption (logic)Atomic physicsDecay heatPenning trapBeta decayParticle detectorPhysical Review Letters
researchProduct

Gamma-ray position reconstruction in large lanthanum-halide crystals with SiPM readout: analytical vs. neural-network algorithms

2019

The main objective of this research was to achieve an excellent gamma-ray position reconstruction with very large monolithic scintillation crystals coupled to pixelated silicon photosensors. Analyzing the scintillation-light distribution measured along the SiPM-pixels one can get a sub-pixel accuracy for the position reconstruction. The quality of the latter depends on both the characteristics of the crystal-photosensor assembly, and the goodness of the algorithm used to reconstruct the gamma-ray hit location. We have carried out a systematic study for 511 keV gamma-rays using three different crystal thicknesses of 10 mm, 20 mm and 30 mm, all of them with planar geometry and a base size of …

ScintillationMaterials sciencePhysics::Instrumentation and Detectors010308 nuclear & particles physicsDetectorPhotodetector01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineSilicon photomultiplierQuality (physics)Position (vector)0103 physical sciencesMedical imagingAlgorithmImage resolution
researchProduct

Two-dimensional transthoracic echocardiographic normal reference ranges for proximal aorta dimensions: Results from the EACVI NORRE study

2017

International audience; AIMS: To report normal reference ranges for echocardiographic dimensions of the proximal aorta obtained in a large group of healthy volunteers recruited using state-of-the-art cardiac ultrasound equipment, considering different measurement conventions, and taking into account gender, age, and body size of individuals. METHODS AND RESULTS: A total of 704 (mean age: 46.0 ± 13.5 years) healthy volunteers (310 men and 394 women) were prospectively recruited from the collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was obtained in all subjects following pre-defined protocols. Aortic…

MaleAorta ThoracicSex Factor030204 cardiovascular system & hematologyReproducibility of resultCohort Studies0302 clinical medicineDiastoleMedicineThoracic aortaAge FactorReference ValueProspective Studies030212 general & internal medicineMultivariate AnalysiBody surface areaCardiac cycleAge FactorsGeneral MedicineNORRE studyMiddle AgedHealthy VolunteerHealthy VolunteersEuropeEchocardiographyNORRE study; echocardiography; reference values; reproducibility of results; sinus of valsalva; thoracic aortaCardiologyLinear Model[SDV.IB]Life Sciences [q-bio]/BioengineeringFemaleCardiology and Cardiovascular MedicineHumanAdultmedicine.medical_specialtySystoleDiastoleNormal valuesThoracic aortaReference values03 medical and health sciencesYoung AdultSex FactorsInternal medicinemedicine.arteryAscending aortaHumansRadiology Nuclear Medicine and imagingMeasurement methodAortaAnalysis of Variancebusiness.industrySinus of valsalvaReproducibility of ResultsMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREProspective StudieMultivariate AnalysisLinear ModelsCohort Studiebusiness
researchProduct

Direct mass measurements ofSe68andY80

2008

The masses of neutron-deficient nuclides near the $N=Z$ line with $A=64\text{\ensuremath{-}}80$ have been determined using a direct time-of-flight technique which employed a cyclotron as a high-resolution spectrometer. The measured atomic masses for $^{68}\mathrm{Se}$ and $^{80}\mathrm{Y}$ were 67.9421(3) u and 79.9344(2) u, respectively. The new values agree with the 2003 Atomic Mass Evaluation. The result for $^{68}\mathrm{Se}$ confirms that this nucleus is a waiting point of the rp-process, and that for $^{80}\mathrm{Y}$ resolves the conflict between earlier measurements. Using the present results and the 2003 Atomic Mass Evaluation compilation, the empirical interaction between the last…

PhysicsNuclear and High Energy PhysicsSpectrometerProton010308 nuclear & particles physicsCyclotron01 natural sciencesAtomic masslaw.inventionNuclear magnetic resonancelaw0103 physical sciencesNeutronNuclideAtomic physicsNuclear Experiment010306 general physicsLine (formation)Physical Review C
researchProduct

Characterization and First Test of an i-TED Prototype at CERN n_TOF

2018

International audience; Neutron capture cross section measurements are of fundamental importance for the study of the slow process of neutron capture, so called s-process. This mechanism is responsible for the formation of most elements heavier than iron in the Universe. To this aim, installations and detectors have been developed, as total energy radiation C$_{6}$ D$_{6}$ detectors. However, these detectors can not distinguish between true capture gamma rays from the sample under study and neutron induced gamma rays produced in the surroundings of the setup. To improve this situation, we propose (Domingo Pardo in Nucl Instr Meth Phys Res A 825:78–86, 2016, [1]) the use of the Compton princ…

PhysicsAstrophysics::High Energy Astrophysical PhenomenaDetectorGamma rayi-TED n_TOF characterizationNeutron radiationRadiation[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]030218 nuclear medicine & medical imagingNuclear physics03 medical and health sciencesNeutron capture0302 clinical medicineNeutron cross sectionNeutronGamma spectroscopy[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]iTED n_TOF neutron
researchProduct

Migration of Nuclear Shell Gaps Studied in thed(Ne24,pγ)Ne25Reaction

2010

The transfer of neutrons onto 24Ne has been measured using a reaccelerated radioactive beam of 24Ne to study the (d,p) reaction in inverse kinematics. The unusual raising of the first 3/2+ level in 25Ne and its significance in terms of the migration of the neutron magic number from N=20 to N=16 is put on a firm footing by confirmation of this state's identity. The raised 3/2+ level is observed simultaneously with the intruder negative parity 7/2- and 3/2- levels, providing evidence for the reduction in the N=20 gap. The coincident gamma-ray decays allowed the assignment of spins as well as the transferred orbital angular momentum. The excitation energy of the 3/2+ state shows that the estab…

PhysicsNuclear reactionAngular momentum010308 nuclear & particles physicsAstrophysics::High Energy Astrophysical PhenomenaHadronGeneral Physics and AstronomyElementary particle01 natural sciencesNuclear physicsBaryon0103 physical sciencesNeutronAtomic physics010306 general physicsNucleonRadioactive decayPhysical Review Letters
researchProduct

Total absorption study of theβdecay of102,104,105Tc

2013

The $\ensuremath{\beta}$-feeding probabilities for three important contributors to the decay heat in nuclear reactors, namely ${}^{102,104,105}$Tc, have been measured using the total absorption spectroscopy technique. For the measurements, sources of very high isobaric purity have been obtained using a Penning trap (JYFLTRAP). A detailed description of the data analysis is given and the results are compared with high-resolution measurements and theoretical calculations.

Nuclear physicsPhysicsNuclear and High Energy PhysicsTotal absorption spectroscopyBeta (plasma physics)Double beta decayIsobaric processAbsorption (logic)Decay heatAtomic physicsPenning trapBeta decayPhysical Review C
researchProduct