0000000000149621

AUTHOR

Dieter Lubda

Evaluation and comparison of tailor-made stationary phases based on spherical silica-based beads for capillary electrochromatography via peptide separation analysis.

Small cyclic peptides have been employed to elucidate the performance of novel sorbents as stationary phases in capillary electrochromatography (CEC). In this paper chain length dependencies for ordinary liquid chromatographic sorbents are reported together with findings acquired on beads specifically designed to suit CEC. The latter, tailor-made, spherical, porous silica exhibits a distinguished surface modification to meet the criteria anticipated to enhance performance profiles in CEC. With well-characterised peptides resembling the analytes, probing of the CEC system in a systematic manner (predominantly via the organic modifier content of the background electrolyte (BE)) reveals insigh…

research product

Making Broad Proteome Protein Measurements in 1−5 min Using High-Speed RPLC Separations and High-Accuracy Mass Measurements

The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both…

research product

Profiling of endogenous peptides by multidimensional liquid chromatography: On-line automated sample cleanup for biomarker discovery in human urine.

A simple and flexible system, employing a column switching technique, has been designed to allow the analysis of peptides and proteins smaller than 15 kDa by molecular weight in filtered urine samples by performing a direct on-column injection utilising simultaneous sample clean-up and trace enrichment. The positively charged peptides and small proteins in the sample are attracted to the inner, negatively charged pore structure of the RAM-SCX column while the larger proteins and uncharged or negatively charged compounds are excluded. After preconditioning with the biological sample, large amounts of sample can be injected. Several important and adjustable parameters for the proper use of a …

research product

Pore structural characterization of monolithic silica columns by inverse size-exclusion chromatography

In this work, a parallel pore model (PPM) and a pore network model (PNM) are developed to provide a state-of-art method for the calculation of several characteristic pore structural parameters from inverse size-exclusion chromatography (ISEC) experiments. The proposed PPM and PNM could be applicable to both monoliths and columns packed with porous particles. The PPM and PNM proposed in this work are able to predict the existence of the second inflection point in the experimental exclusion curve that has been observed for monolithic materials by accounting for volume partitioning of the polymer standards in the macropores of the column. The appearance and prominence of the second inflection …

research product

Analysis of neuropeptide Y and its metabolites by high-performance liquid chromatography-electrospray ionization mass spectrometry and integrated sample clean-up with a novel restricted-access sulphonic acid cation exchanger.

A novel restricted access cation exchanger with sulphonic acid groups at the internal surface was proven to be highly suitable in the sample clean up of peptides on-line coupled to HPLC-electrospray ionization (ESI)-MS. Neuropeptide Y (NPY) and several of its fragments in plasma were subjected to the sample clean-up procedure. The peptides were eluted by a step gradient from the restricted access column, applying 10 mM phosphate buffer pH 3.5 from 5 to 20% (v/v) of acetonitrile with 1 M NaCl and transferred to a Micra ODS II column (33x4.6 mm). The separation of the peptides and their fragments was performed by a linear gradient from 20 to 60% (v/v) acetonitrile in water with 0.1% formic ac…

research product

Comprehensive pore structure characterization of silica monoliths with controlled mesopore size and macropore size by nitrogen sorption, mercury porosimetry, transmission electron microscopy and inverse size exclusion chromatography

The porosity of monolithic silica columns is measured by using different analytical methods. Two sets of monoliths were prepared with a given mesopore diameter of 10 and 25 nm, respectively and with gradated macropore diameters between 1.8 and 7.5 microm. After preparing the two sets of monolithic silica columns with different macro- and mesopores the internal, external and total porosity of these columns are determined by inverse size-exclusion chromatography (ISEC) using polystyrene samples of narrow molecular size distribution and known average molecular weight. The ISEC data from the 4.6 mm analytical monolithic silica columns are used to determine the structural properties of monolithi…

research product

Ultrahigh-Throughput Proteomics Using Fast RPLC Separations with ESI-MS/MS

We describe approaches for proteomics analysis using electrospray ionization-tandem mass spectrometry coupled with fast reversed-phase liquid chromatography (RPLC) separations. The RPLC separations used 50-microm-i.d. fused-silica capillaries packed with submicrometer-sized C18-bonded porous silica particles and achieved peak capacities of 130-420 for analytes from proteome tryptic digests. When these separations were combined with linear ion trap tandem mass spectrometry measurements, approximately 1000 proteins could be identified in 50 min from approximately 4000 identified tryptic peptides; approximately 550 proteins in 20 min from approximately 1800 peptides; and approximately 250 prot…

research product

Monolithic silica columns of various format in automated sample clean-up/multidimensional liquid chromatography/mass spectrometry for peptidomics.

The following particulate and monolithic silica columns were implemented in a fully automated and flexible multidimensional LC/MS system with integrated sample clean-up, to perform the analysis of endogeneous peptides from filtered urine and plasma samples: restricted access sulphonic acid strong cation-exchanger (RAM-SCX) for sample clean-up, RP 18 Chromolith guard columns as trap columns and 100 microm I.D. monolithic RP 18 fused silica capillary columns as last LC dimension. The results show sufficient overall system reproducibility and repeatability. Implementation of monolithic silica columns added an additional flexibility with respect to flow rate variation and adjustment due to the …

research product

Sulphonic acid strong cation-exchange restricted access columns in sample cleanup for profiling of endogeneous peptides in multidimensional liquid chromatography

Abstract In this work, the pore structural parameters and size exclusion properties of LiChrospher strong cation-exchange and reverse phase restricted access materials (RAM) are analysed. The molecular weight size exclusion limit for polystyrenes was found to be about 17.7 kDa, while for standard proteins, the molecular weight size exclusion limit was higher, at approximately 25 kDa. The average pore diameter on a volume basis calculated from the pore network model changes from 8.5 nm (native LiChrospher) to 8.6 nm (diol derivative) to 8.2 nm (sulphonic acid derivative) to 6.9 nm ( n -octadecyl derivative). Additional characterisations were performed on restricted access materials with nitr…

research product

Evaluation and comparison of the pore structure and related properties of particulate and monolithic silicas for liquid phase separation processes

Two types of silicas, highly porous beads of 10 μm average particle diameter and particle porosity between 48 to 86 % and monolithic silicas with constant mesopore diameter of 12 nm, constant total porosity of 80 % at variable macropore diameter between 2 and 6 μm were subjected to pore structural characterisation and tests in high performance liquid chromatography (HPLC). The column permeability KF of the columns packed with highly porous beads was twice as much as for the monolithic silica columns. The differences in theoretical plate height - linear velocity curves could be explained on the basis of the pore connectivity values nT of the materials which were computed from the nitrogen so…

research product

Textural characterization of native and n-alky-bonded silica monoliths by mercury intrusion/extrusion, inverse size exclusion chromatography and nitrogen adsorption

Native and n-alkyl-bonded (n-octadecyl) monolithic silica rods with mesopores in the range between 10 and 25 nm and macropores in the range between 1.8 and 6.0 microm were examined by mercury intrusion/extrusion, inverse size exclusion chromatography (ISEC) and nitrogen sorption. Our results reveal very good agreement for the mesopore size distribution obtained from nitrogen adsorption (in combination with an advanced NLDFT analysis) and ISEC. Our studies highlight the importance of mercury porosimetry for the assessment of the macropore size distribution and show that mercury porosimetry is the only method which allows obtaining a combined and comprehensive structural characterization of m…

research product

Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins

In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Bo…

research product

SilicaROD™ — A new challenge in fast high-performance liquid chromatography separations

Abstract High performance liquid chromatography (HPLC) has become one of the most used methods for the analysis of compound mixtures in industry, especially for the quality control of products. Nowadays productivity is the major and dominant upcoming issue, i.e. the goal is to drastically reduce the analysis time and cost per analysis. The solution of the task is higher throughput and faster HPLC methods. Here we describe a new monolithic type of HPLC column, the SilicaROD™ column, which permits the fast HPLC separation of compound mixtures within a few minutes.

research product

Dynamic electric field assisted multi-dimensional liquid chromatography of biological samples

Complex biological samples require very high resolution separation strategies. The platform introduced here capitalises on the hyphenation of liquid chromatographic (LC) and electric potential gradient electrochromatographic multi-dimensional separation genres. First-dimension selectivity is provided by simultaneous size exclusion (SEC) and strong cation exchange (SCX) chromatography modes, while the second dimension comprises reversed phase (RP) characteristics in a dynamic (time-variant) electric field. The time-variant potential gradient with reversal of polarity is applied across the second dimension monolithic capillary throughout the duration of the solvent strength gradient elution. …

research product