0000000000161157

AUTHOR

Bayden R. Wood

showing 9 related works from this author

Inside Cover: Red Blood Cells Polarize Green Laser Light Revealing Hemoglobin′s Enhanced Non-Fundamental Raman Modes (ChemPhysChem 18/2014)

2014

Hemoglobin ssymbols.namesakeGreen laser lightbusiness.industryChemistrysymbolsAnalytical chemistryOptoelectronicsCover (algebra)Physical and Theoretical ChemistryRaman spectroscopybusinessAtomic and Molecular Physics and OpticsChemPhysChem
researchProduct

Addressing Delicate and Variable Cancer Morphology in Spectral Histopathology Using Canine Visceral Hemangiosarcoma

2021

Spectral histopathology has shown promise for the classification and diagnosis of tumors with defined morphology, but application in tumors with variable or diffuse morphologies is yet to be investigated. To address this gap, we evaluated the application of Fourier transform infrared (FTIR) imaging as an accessory diagnostic tool for canine hemangiosarcoma (HSA), a vascular endothelial cell cancer that is difficult to diagnose. To preserve the delicate vascular tumor tissue structure, and potential classification of single endothelial cells, paraffin removal was not performed, and a partial least square discrimination analysis (PLSDA) and Random Forest (RF) models to classify different tiss…

medicine.medical_specialtyCancer morphologyHemangiosarcomaCalibration set02 engineering and technology01 natural sciencesAnalytical ChemistryDogsSpectroscopy Fourier Transform InfraredmedicineAnimalsLeast-Squares AnalysisChemistry010401 analytical chemistryEndothelial Cells021001 nanoscience & nanotechnologymedicine.diseaseCanine Hemangiosarcoma0104 chemical sciencesHemangiosarcomaVascular tumorHistopathologyDifferential diagnosis0210 nano-technologySpleenBiomedical engineeringAnalytical Chemistry
researchProduct

ATR-Spin: an open-source 3D printed device for direct cytocentrifugation onto attenuated total reflectance crystals.

2021

Infrared Spectroscopy (IR) enables the direct and rapid characterization of cells at the molecular level. Achieving a rapid and consistent cell preparation is critical for the development of Point-of-Care diagnostics for cell analysis. Here we introduce an open-source, 3D printed device for integrating the isolation, preconcentration, and measurement of attenuated total reflectance IR spectra of cells from biofluids. The tool comprises a disposable card for cytocentrifugation, equipped with magnets, which allows reproducible integration into the pathlength of the IR spectrophotometer. Preliminary results using cell media containing A459 cells indicate that this system enables a qualitative …

3d printedMaterials scienceSpectrophotometry Infraredbusiness.industryCell preparation010401 analytical chemistryBiomedical EngineeringInfrared spectroscopyBioengineeringCell analysis02 engineering and technologyGeneral Chemistry021001 nanoscience & nanotechnology01 natural sciencesBiochemistry0104 chemical sciencesOpen sourceMolecular levelAttenuated total reflectionPrinting Three-DimensionalSpectroscopy Fourier Transform InfraredOptoelectronics0210 nano-technologybusinessLab on a chip
researchProduct

Red Blood Cells Polarize Green Laser Light Revealing Hemoglobin's Enhanced Non-Fundamental Raman Modes

2014

In general, the first overtone modes produce weak bands that appear at approximately twice the wavenumber value of the fundamental transitions in vibrational spectra. Here, we report the existence of a series of enhanced non-fundamental bands in resonance Raman (RR) spectra recorded for hemoglobin (Hb) inside the highly concentrated heme environment of the red blood cell (RBC) by exciting with a 514.5 nm laser line. Such bands are most intense when detecting parallel-polarized light. The enhancement is explained through excitonic theory invoking a type C scattering mechanism and bands have been assigned to overtone and combination bands based on symmetry arguments and polarization measureme…

ErythrocytesOvertonePlasmodium falciparumAnalytical chemistryporphyrinoidsmalaria diagnosticHemeSpectrum Analysis RamanMolecular physicsSpectral linelaw.inventionchemistry.chemical_compoundsymbols.namesakeHemoglobinslawHumansPhysical and Theoretical ChemistryMalaria FalciparumSpectroscopyHemeScatteringLasersArticlesLaserPolarization (waves)Atomic and Molecular Physics and OpticschemistryRaman spectroscopysymbolsRaman spectroscopyovertone/combination modesred blood cellsChemphyschem
researchProduct

ATR-FTIR spectroscopy as a quality control system for monitoring the storage of blood products

2021

Blood screening is a fundamental part of disease diagnosis and monitoring health. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy offers an innovative solution to streamlining the process, especially for multianalyte detection in aqueous samples. However, samples always undergo a storage phase before they are processed for testing and blood transfusion. In this study, we investigated the effect of standard storage procedures on the macromolecular composition of whole blood, and plasma collected in blood tubes for diagnostic purposes and initial screening of blood products. Periphery blood samples were collected from 10 volunteers and then stored for 14 days a…

Quality ControlErythrocytesBlood transfusionResolution (mass spectrometry)General Chemical Engineeringmedicine.medical_treatmentInfrared spectroscopyAtaxia Telangiectasia Mutated Proteins01 natural sciencesAnalytical Chemistry03 medical and health sciencesSpectroscopy Fourier Transform InfraredPartial least squares regressionmedicineHumansLeast-Squares Analysis030304 developmental biologyWhole bloodBlood Specimen Collection0303 health sciencesChromatographyFourier AnalysisChemistry010401 analytical chemistryGeneral EngineeringBlood Screening0104 chemical sciencesBloodQuality control systemAttenuated total reflectionAnalytical Methods
researchProduct

Assessment of the statistical significance of classifications in infrared spectroscopy based diagnostic models.

2014

Fourier transform infrared (IR) spectroscopy in combination with multivariate data analysis is a versatile tool that can be applied to disease diagnosis. However, a rigorous validation of the obtained models is necessary in order to obtain robust results. This work evaluates the advantages of the use of permutation testing for determining the statistical significance of the misclassification errors obtained from IR based diagnostic models through cross validation (CV). The model performance, estimated by CV, is compared to a distribution of CV-performance values obtained using randomly permuted class labels. The distribution of ‘random CV-values’ is considered as a null distribution and use…

Multivariate analysisFeature selectionClinical Chemistry Tests02 engineering and technology01 natural sciencesBiochemistryCross-validationAnalytical ChemistryResamplingStatisticsDiagnosisSpectroscopy Fourier Transform InfraredElectrochemistryNull distributionEnvironmental ChemistryHumansSpectroscopyMathematicsModels Statistical010401 analytical chemistryEstimatorContrast (statistics)Discriminant AnalysisReproducibility of Results021001 nanoscience & nanotechnology0104 chemical sciencesRandom forest0210 nano-technologyThe Analyst
researchProduct

Infrared based saliva screening test for COVID‐19

2021

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in an unprecedented need for diagnostic testing that is critical in controlling the spread of COVID-19. We propose a portable infrared spectrometer with purpose-built transflection accessory for rapid point-of-care detection of COVID-19 markers in saliva. Initially, purified virion particles were characterized with Raman spectroscopy, synchrotron infrared (IR) and AFM-IR. A data set comprising 171 transflection infrared spectra from 29 subjects testing positive for SARS-CoV-2 by RT-qPCR and 28 testing negative, was modeled using Monte Carlo Double Cross Validation with 50 randomized test and model sets. The testing se…

SalivaMaterials scienceCoronavirus disease 2019 (COVID-19)Spectrophotometry InfraredInfraredPoint-of-care testingInfrared spectroscopy010402 general chemistry01 natural sciencesProof of Concept StudySensitivity and SpecificityCatalysisSpecimen HandlingCohort Studies03 medical and health sciences0302 clinical medicineCOVID-19 TestingSpectrophotometryChlorocebus aethiopsmedicineCOVID-19 diagnostic infrared spectroscopy Raman spectroscopy saliva SARS-CoV-2 virionsAnimalsHumansQDLeast-Squares AnalysisSalivaVero CellsMass screening030304 developmental biologyDetection limit0303 health sciencessalivaChromatographymedicine.diagnostic_test010405 organic chemistrySARS-CoV-2COVID-19Discriminant AnalysisGeneral Chemistry030206 dentistryGeneral Medicine0104 chemical sciences3. Good healthPoint-of-Care TestingMonte Carlo MethodATR-FTIRResearch ArticleAngewandte Chemie (International Ed. in English)
researchProduct

Comparison of transflection and transmission FTIR imaging measurements performed on differentially fixed tissue sections

2015

The widespread and cost-effective use of transflection substrates in Fourier transform infrared (FTIR) imaging of clinical samples is affected by the presence of artefacts including the electric field standing wave (EFSW) and contributions from light dispersion. For IR-based diagnostics, the manifestation of undesirable artifacts can distort the spectra and lead to erroneous diagnosis. Nevertheless, there is no clear consensus in the literature about the degree of influence of these effects. The aim of this work is to contribute to this discussion by comparing transflection and transmission images of the same tissue. For this purpose two adjacent sections of the same tissue (lymphoma sample…

Tissue FixationLymphomaChemistryOptical ImagingAnalytical chemistryHyperspectral imagingBiochemistryAnalytical ChemistryAbsorbancesymbols.namesakeNuclear magnetic resonanceTissue sectionsFourier transformTransmission (telecommunications)Light dispersionSpectroscopy Fourier Transform InfraredElectrochemistrysymbolsEnvironmental ChemistryImage acquisitionFourier transform infrared spectroscopyArtifactsSpectroscopy
researchProduct

Dataset and Data analysis for "Infrared based saliva screening test for COVID-19"

2021

External Modelling 1 is the Quasar .ows model to process the Source data 1 to generate the PCA plot shown in Figure 4B and loadings plots in Figure 4C. External Modelling 2 is the MCDCV-PLS-DA Matlab model that can be used in combination with PLS-Tool Box to generate the Receiver Operating Curves (ROC) and the prediction model shown in Figures 4D and 4E, respectively. Source Data 1 is for the PCA modelling. Source Data 2 for the MCDCV-PLS-DA.

COVID-19InfraredSpectroscopyMatlab
researchProduct