Echocardiographic reference ranges for normal left ventricular 2D strain: results from the EACVI NORRE study
International audience; Aims - To obtain the normal ranges for 2D echocardiographic (2DE) measurements of left ventricular (LV) strain from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 549 (mean age: 45.6 ± 13.3 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. 2DE data sets have been analysed with a vendor-independent software package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire the data sets. The lowest expected values of LV strains and twist calculated as ± 1.96 standard deviations from the mean…
Echocardiographic reference ranges for normal cardiac Doppler data: results from the NORRE Study
International audience; AIMS: Reference values for Doppler parameters according to age and gender are recommended for the assessment of heart physiology, specifically for left ventricular (LV) diastolic function. In this study, we report normal reference ranges for Doppler parameters obtained in a large group of healthy volunteers. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following Doppler acquisition and measurement protocols approved by the European Association of Cardiovascular Imaging. METHODS AND RESULTS: A total of 449 (mean age: 45.8 ± 13.7 years) healthy volunteers (198 men and 251 women) were enrolled at the collaborating institutions…
Echocardiographic reference ranges for normal cardiac chamber size: Results from the NORRE study
AimsAvailability of normative reference values for cardiac chamber quantitation is a prerequisite for accurate clinical application of echocardiography. In this study, we report normal reference ranges for cardiac chambers size obtained in a large group of healthy volunteers accounting for gender and age. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following chamber quantitation protocols approved by the European Association of Cardiovascular Imaging.MethodsA total of 734 (mean age: 45.8 ± 13.3 years) healthy volunteers (320 men and 414 women) were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORR…
Echocardiographic reference ranges for normal left ventricular layer-specific strain: results from the EACVI NORRE study
Abstract Aims To obtain the normal range for 2D echocardiographic (2DE) measurements of left ventricular (LV) layer-specific strain from a large group of healthy volunteers of both genders over a wide range of ages. Methods and results A total of 287 (109 men, mean age: 46 ± 14 years) healthy subjects were enrolled at 22 collaborating institutions of the EACVI Normal Reference Ranges for Echocardiography (NORRE) study. Layer-specific strain was analysed from the apical two-, three-, and four-chamber views using 2DE software. The lowest values of layer-specific strain calculated as ±1.96 standard deviations from the mean were −15.0% in men and −15.6% in women for epicardial strain, −16.8% …
3D echocardiographic reference ranges for normal left ventricular volumes and strain: results from the EACVI NORRE study
International audience; Aim: To obtain the normal ranges for 3D echocardiography (3DE) measurement of left ventricular (LV) volumes, function, and strain from a large group of healthy volunteers. Methods and results: A total of 440 (mean age: 45 ± 13 years) out of the 734 healthy subjects enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study had good-quality 3DE data sets that have been analysed with a vendor-independent software package allowing homogeneous measurements regardless of the echocardiographic machine used to acquire the data sets. Upper limits of LV end-diastolic and end-systolic volumes were larger in men (97 and 42 mL/m2)…
Two-dimensional transthoracic echocardiographic normal reference ranges for proximal aorta dimensions: Results from the EACVI NORRE study
International audience; AIMS: To report normal reference ranges for echocardiographic dimensions of the proximal aorta obtained in a large group of healthy volunteers recruited using state-of-the-art cardiac ultrasound equipment, considering different measurement conventions, and taking into account gender, age, and body size of individuals. METHODS AND RESULTS: A total of 704 (mean age: 46.0 ± 13.5 years) healthy volunteers (310 men and 394 women) were prospectively recruited from the collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was obtained in all subjects following pre-defined protocols. Aortic…
Echocardiographic reference ranges for normal non-invasive myocardial work indices: results from the EACVI NORRE study
International audience; Aims - To obtain the normal ranges for 2D echocardiographic (2DE) indices of myocardial work (MW) from a large group of healthy volunteers over a wide range of ages and gender. Methods and results - A total of 226 (85 men, mean age: 45 ± 13 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. Global work index (GWI), global constructive work (GCW), global work waste (GWW), and global work efficiency (GWE) were estimated from left ventricle (LV) pressure-strain loops. Peak LV systolic pressure was non-invasively derived from brachial artery cuff pressure. The lowest values of MW indic…
Echocardiographic reference ranges for normal left atrial function parameters results from the EACVI NORRE study
International audience; Aims - To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function we…
Correlation between non-invasive myocardial work indices and main parameters of systolic and diastolic function
Abstract Aims The present study sought to evaluate the correlation between indices of non-invasive myocardial work (MW) and left ventricle (LV) size, traditional and advanced parameters of LV systolic and diastolic function by 2D echocardiography (2DE). Methods and results A total of 226 (85 men, mean age: 45 ± 13 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. Global work index (GWI), global constructive work (GCW), global work waste (GWW), and global work efficiency (GWE) were estimated from LV pressure-strain loops using custom software. Peak LV pressure was estimated non-invasively from brachial ar…