0000000000345164
AUTHOR
Till Humbert
Determination of α-Tocopherol in Plasma by High Performance Liquid Chromatography with Fluorescence Detection and Stability of α-Tocopherol under Different Conditions
In order to study the clinical effects of the antioxidant alpha-tocopherol (tocofersolan, CAS 30999-06-5) a simple, robust, sensitive and reliable high performance liquid chromatography (HPLC) method using fluorescence detection for the daily measurement of alpha-tocopherol concentration in plasma is described. Several methods of HPLC analysis using fluorescence techniques are published, however, investigations of the stability of alpha-tocopherol during sample preparation under different conditions are relevant in the routine measurements and have to date not been reported. Therefore a modified method, both sensitive and robust, qualified for the day-by-day measurement of alpha-tocopherol …
Metabolic Clearance of the Antioxidant Ascorbic Acid in Surgical Patients1
Background A reduction of plasma ascorbic acid concentration in the post-operative period has been well documented and is associated with an increase in post-operative complications. The underlying reason for the decreased concentration of ascorbic acid in the plasma is not clear. However, only an increased post-operative requirement for ascorbic acid would justify a substitution. Therefore, we investigated the pre-operative and post-operative metabolic clearance of ascorbic acid. Materials and Methods We calculated the metabolic clearance subsequent to intravenous bolus injection of 6 mg ascorbic acid/kg body weight in 15 patients before and after they underwent major maxillofacial surgery…
A minimally invasive approach for aortobifemoral bypass procedure
Surgical aortobifemoral bypass procedure for aortoiliac occlusive disease remains the gold standard treatment despite rapidly expanding range of indications for endovascular repair. Besides several disadvantages such as dysparaesthesias, hernias, and unpleasant outcome, transperitoneal exposure of the aorta is also associated with operative autonomic nerve injury. In five male patients, infrarenal aorta was exposed through a small (8 cm) supraumbilical midline incision. Incision of the posterior peritoneum above the infrarenal aorta was limited to 3 cm. A 1 cm infraumbilical incision allowed transperitoneal placement of the distal aortic clamp outside of the operative field. Four centimeter…
Ceftazidime Determination in Serum by High-pressure Liquid Chromatography
A rapid and sensitive high-pressure liquid chromatographic method with simple sample preparation was developed for the quantitative analysis of the beta-lactam antibiotic ceftazidime (CAS 78439-06-2, Fortum). A good linear relationship was established between the peak area and the amount of ceftazidime injected over a concentration range of 1 to 200 microg/ml. The detection limit of the method was calculated to be 0.9 microg/ml. Stability was shown at 4 degrees C and at -196 degrees C for time periods of 2 h and 84 days, respectively.