0000000000435271
AUTHOR
Nívia M. M. Coelho
Determination of nitrogen in hydrolyzed protein formulations by continuous vapour phase FTIR.
An on-line system with vapour generation (VG) and Fourier transform infrared (FTIR) spectrometric detection has been developed for the determination of free ammonium and organic nitrogen in agrochemical formulations containing hydrolyzed proteins. Commercial samples were digested, in batch mode, with sulphuric acid and the obtained solution was alkalinized on-line to transform the NH(4)(+) to NH(3) that was continuously monitored by FTIR. Free ammonium was determined in the same system after simple dilution of undigested samples with water. Different gas phase separators were assayed in order to introduce gaseous NH(3) into a home made IR gas cell of 10 cm pathlength, where the correspondin…
Food Chemistry: Food quality and new analytical approaches
Peer Reviewed
Seafood freshness determination through vapour phase Fourier transform infrared spectroscopy.
Abstract A new vapour-phase manifold has been developed to determine trimethylamine (TMA) in fish and cephalopod samples by Fourier transform infrared (FT-IR) spectroscopy. Samples were treated off-line for 1 h with trichloroacetic acid (TCA), filtered and washed. The obtained extracts were aspirated and alkalinized with NaOH 2.0 M, in an on-line system. TMA was separated from the solution in a gas phase separator and then transported by means of a nitrogen carrier into a home made 10 cm pathlength IR gas cell, where the corresponding FT-IR spectra were acquired by accumulating 30 scans per spectrum with 2 cm−1 nominal resolution. The method was applied to the determination of TMA in natura…
Determination of arsenic compounds in beverages by high-performance liquid chromatography-inductively coupled plasma mass spectrometry.
Arsenic compounds including arsenous acid (As(III)), arsenic acid (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were separated by high-performance liquid chromatography (HPLC) and detected by inductively coupled plasma mass spectrometry (ICP-MS). A Hamilton PRX-100 anionic-exchange column and a pH 8.5 K(2)HPO(4)/KH(2)PO(4) 5.0x10(-3)molL(-1) mobile phase were used to achieve arsenic speciation. The separation of arsenic species provided peaks of As(III) at 2.75min, DMA at 3.33min, MMA at 5.17min and As(V) at 12.5min. The detection limits, defined as three times the standard deviation of the lowest standard measurements, were found to be 0.2, 0.2, 0.3 and 0.5ngmL(-1) f…
On-line bi-directional electrostacking for As speciation/preconcentration using electrothermal atomic absorption spectrometry.
A method using bi-directional electrostacking (BDES) in a flow system is presented for As preconcentration and speciation analysis. Some parameters such as electrostacking time and applied voltage, support buffers and their concentrations were investigated. Boric acid plus sodium hydroxide at 0.1mol/l concentration was selected as support buffer to improve the pre-concentration factor (PF) for As(V). An analytical range from 2.0 to 50.0mugl(-1), and 0.35mugl(-1) as limit of detection, when applied 750V for 20min, were achieved. Under these conditions, a pre-concentration factor of 4.8 was obtained. The proposed method was applied to determine As(V) in mineral water and natural water samples…