0000000000441457

AUTHOR

Luciana Melo Coelho

showing 3 related works from this author

Food Chemistry: Food quality and new analytical approaches

2016

Peer Reviewed

lcsh:ChemistryArticle Subjectlcsh:QD1-999ChemistryeducationGeneral ChemistryFood chemistryFood scienceFood qualityAgricultural economics
researchProduct

Determination of arsenic compounds in beverages by high-performance liquid chromatography-inductively coupled plasma mass spectrometry.

2005

Arsenic compounds including arsenous acid (As(III)), arsenic acid (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were separated by high-performance liquid chromatography (HPLC) and detected by inductively coupled plasma mass spectrometry (ICP-MS). A Hamilton PRX-100 anionic-exchange column and a pH 8.5 K(2)HPO(4)/KH(2)PO(4) 5.0x10(-3)molL(-1) mobile phase were used to achieve arsenic speciation. The separation of arsenic species provided peaks of As(III) at 2.75min, DMA at 3.33min, MMA at 5.17min and As(V) at 12.5min. The detection limits, defined as three times the standard deviation of the lowest standard measurements, were found to be 0.2, 0.2, 0.3 and 0.5ngmL(-1) f…

Detection limitchemistry.chemical_compoundChromatographyCertified reference materialsChemistryArsenous acidchemistry.chemical_elementArsenic CompoundHigh-performance liquid chromatographyArsenic acidInductively coupled plasma mass spectrometryArsenicAnalytical ChemistryTalanta
researchProduct

On-line bi-directional electrostacking for As speciation/preconcentration using electrothermal atomic absorption spectrometry.

2006

A method using bi-directional electrostacking (BDES) in a flow system is presented for As preconcentration and speciation analysis. Some parameters such as electrostacking time and applied voltage, support buffers and their concentrations were investigated. Boric acid plus sodium hydroxide at 0.1mol/l concentration was selected as support buffer to improve the pre-concentration factor (PF) for As(V). An analytical range from 2.0 to 50.0mugl(-1), and 0.35mugl(-1) as limit of detection, when applied 750V for 20min, were achieved. Under these conditions, a pre-concentration factor of 4.8 was obtained. The proposed method was applied to determine As(V) in mineral water and natural water samples…

Detection limitmedia_common.quotation_subjectAnalytical chemistrychemistry.chemical_elementAnalytical Chemistrylaw.inventionBoric acidchemistry.chemical_compoundSpeciationPotassium permanganateMineral waterchemistrySodium hydroxidelawAtomic absorption spectroscopyArsenicmedia_commonTalanta
researchProduct