Evaluation of the effect of chance correlations on variable selection using Partial Least Squares -Discriminant Analysis

2013

Variable subset selection is often mandatory in high throughput metabolomics and proteomics. However, depending on the variable to sample ratio there is a significant susceptibility of variable selection towards chance correlations. The evaluation of the predictive capabilities of PLSDA models estimated by cross-validation after feature selection provides overly optimistic results if the selection is performed on the entire set and no external validation set is available. In this work, a simulation of the statistical null hypothesis is proposed to test whether the discrimination capability of a PLSDA model after variable selection estimated by cross-validation is statistically higher than t…

Variable selectionESTADISTICA E INVESTIGACION OPERATIVAFeature selectionChance correlationsAnalytical ChemistrySet (abstract data type)ResamplingPartial least squares regressionStatisticsHumansMetabolomicsLeast-Squares AnalysisSelection (genetic algorithm)ProbabilityGaucher DiseaseModels StatisticalChemistryDiscriminant AnalysisReproducibility of ResultsPartial Least Squares-Discriminant Analysis (PLSDA)Linear discriminant analysisVariable (computer science)Null hypothesisAlgorithmsSoftware
researchProduct

Atmospheric compensation in Fourier transform infrared (FT-IR) spectra of clinical samples.

2013

A new method is proposed for the elimination of the spectral contribution of two atmospheric gases (CO2 and H2O) in Fourier transform infrared (FT-IR) spectra of clinical samples. The algorithm is based on the measurement of reference spectra of H2O followed by an automatic calculation of the spectral contribution of the above-mentioned gases to the sample spectra. Then this contribution is compensated by spectral subtraction. Attenuated total reflectance FT-IR spectra of serum and urine samples in the presence of atmospheric gases were corrected and compared with spectra obtained with an N2 purge. Visual inspection of the spectra as well as calculated noise levels confirmed that the metho…

ChemistryInfraredbusiness.industryAnalytical chemistryInfrared spectroscopyNoise (electronics)Spectral lineChemometricssymbols.namesakeOpticsFourier transformAttenuated total reflectionsymbolsFourier transform infrared spectroscopybusinessInstrumentationSpectroscopyApplied spectroscopy
researchProduct

Inside Cover: Red Blood Cells Polarize Green Laser Light Revealing Hemoglobin′s Enhanced Non-Fundamental Raman Modes (ChemPhysChem 18/2014)

2014

Hemoglobin ssymbols.namesakeGreen laser lightbusiness.industryChemistrysymbolsAnalytical chemistryOptoelectronicsCover (algebra)Physical and Theoretical ChemistryRaman spectroscopybusinessAtomic and Molecular Physics and OpticsChemPhysChem
researchProduct

Addressing Delicate and Variable Cancer Morphology in Spectral Histopathology Using Canine Visceral Hemangiosarcoma

2021

Spectral histopathology has shown promise for the classification and diagnosis of tumors with defined morphology, but application in tumors with variable or diffuse morphologies is yet to be investigated. To address this gap, we evaluated the application of Fourier transform infrared (FTIR) imaging as an accessory diagnostic tool for canine hemangiosarcoma (HSA), a vascular endothelial cell cancer that is difficult to diagnose. To preserve the delicate vascular tumor tissue structure, and potential classification of single endothelial cells, paraffin removal was not performed, and a partial least square discrimination analysis (PLSDA) and Random Forest (RF) models to classify different tiss…

medicine.medical_specialtyCancer morphologyHemangiosarcomaCalibration set02 engineering and technology01 natural sciencesAnalytical ChemistryDogsSpectroscopy Fourier Transform InfraredmedicineAnimalsLeast-Squares AnalysisChemistry010401 analytical chemistryEndothelial Cells021001 nanoscience & nanotechnologymedicine.diseaseCanine Hemangiosarcoma0104 chemical sciencesHemangiosarcomaVascular tumorHistopathologyDifferential diagnosis0210 nano-technologySpleenBiomedical engineeringAnalytical Chemistry
researchProduct

ATR-Spin: an open-source 3D printed device for direct cytocentrifugation onto attenuated total reflectance crystals.

2021

Infrared Spectroscopy (IR) enables the direct and rapid characterization of cells at the molecular level. Achieving a rapid and consistent cell preparation is critical for the development of Point-of-Care diagnostics for cell analysis. Here we introduce an open-source, 3D printed device for integrating the isolation, preconcentration, and measurement of attenuated total reflectance IR spectra of cells from biofluids. The tool comprises a disposable card for cytocentrifugation, equipped with magnets, which allows reproducible integration into the pathlength of the IR spectrophotometer. Preliminary results using cell media containing A459 cells indicate that this system enables a qualitative …

3d printedMaterials scienceSpectrophotometry Infraredbusiness.industryCell preparation010401 analytical chemistryBiomedical EngineeringInfrared spectroscopyBioengineeringCell analysis02 engineering and technologyGeneral Chemistry021001 nanoscience & nanotechnology01 natural sciencesBiochemistry0104 chemical sciencesOpen sourceMolecular levelAttenuated total reflectionPrinting Three-DimensionalSpectroscopy Fourier Transform InfraredOptoelectronics0210 nano-technologybusinessLab on a chip
researchProduct

Synthesis and Biological Evaluation of Combretastatin A-4 and Three Combretastatin-Based Hybrids

2012

The syntheses of combretastatin A-4 from gallic acid and of three combretastatin-based hybrids are described. Starting from commercial gallic acid, the phosphonium salt (3,4,5-trimethoxybenzylphosphonium bromide) is synthesized and coupled, through a Wittig reaction, with several aldehydes, including methoxymethyl-protected isovanillin, the aldehyde γ-bicyclohomofarnesal having a labdane skeleton, 3-(3-pyridyl) propanal, and furfural. The biological properties of the cis-coupled compounds as cytotoxic, antiviral and antifungal agents are also reported. In addition, pyrogallol, gallic and 3,4,5-trimethoxybenzoic acids have been studied biologically.

PharmacologyCombretastatin A-4CombretastatinPhosphonium saltPlant ScienceGeneral MedicineIsovanillinLabdanechemistry.chemical_compoundComplementary and alternative medicinechemistryPyrogallolDrug DiscoveryWittig reactionOrganic chemistryGallic acidNatural Product Communications
researchProduct

Detection of batch effects in liquid chromatography-mass spectrometry metabolomic data using guided principal component analysis.

2014

Metabolomics based on liquid chromatography-mass spectrometry (LC-MS) is a powerful tool for studying dynamic responses of biological systems to different physiological or pathological conditions. Differences in the instrumental response within and between batches introduce unwanted and uncontrolled data variation that should be removed to extract useful information. This work exploits a recently developed method for the identification of batch effects in high throughput genomic data based on the calculation of a delta statistic through principal component analysis (PCA) and guided PCA. Its applicability to LC-MS metabolomic data was tested on two real examples. The first example involved t…

Quality ControlPrincipal Component AnalysisChromatographyChemistryGenomic dataGuided principal component analysisMass spectrometryBatch effectMass SpectrometryAnalytical ChemistryData setPlasmaMetabolomicsLiquid chromatography–mass spectrometryPeak intensityPrincipal component analysisCalibrationLiquid chromatography-mass spectrometry (LC-MS)HumansMetabolomicsBiological systemStatisticChromatography LiquidTalanta
researchProduct

Determination of biochemical parameters in human serum by near-infrared spectroscopy

2014

NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipopr…

AnalyteVery low-density lipoproteinChromatographyMean squared errorChemistryCholesterolGeneral Chemical EngineeringNear-infrared spectroscopyGeneral EngineeringAnalytical chemistryAnalytical ChemistryAbsorbancechemistry.chemical_compoundPartial least squares regressionCalibrationAnalytical Methods
researchProduct

Determination of lidocaine in urine at low ppm levels using dispersive microextraction and attenuated total reflectance–Fourier transform infrared me…

2015

Abstract IR spectra provide valuable information about biological systems and can be obtained with compactable and affordable instruments, but the lack of sensitivity of this technique hampers its use in the determination of drugs in clinical fluids. Taking lidocaine as a target molecule, in this paper we introduced a methodology for determining drugs in urine samples using infrared spectroscopy. The lack of sensitivity of the IR was compensated with the combination of an effective and straightforward dispersive liquid–liquid microextraction and the measurement of the dry film of the organic extracts through attenuated total reflectance (ATR). The method developed improves the sensitivity b…

SolventDetection limitAnalyteChromatographyChemistryAttenuated total reflectionPartial least squares regressionAnalytical chemistryCalibrationInfrared spectroscopyUrineSpectroscopyAnalytical ChemistryMicrochemical Journal
researchProduct

Evaluation of infrared spectroscopy as a screening tool for serum analysis

2013

Abstract The application of attenuated total reflectance Fourier transform infrared (ATR-FT-IR) spectroscopy to the determination of clinical parameters in serum using partial least squares (PLS) has been evaluated as a point-of-care diagnostic tool. In this study the effect of using an increased size of the calibration set and the influence of the origin of samples and their interyear variation on the prediction capability of the method were considered. PLS-ATR-FT-IR provides a green, fast and cheap point-of-care tool for the determination of total protein. Albumin, glucose, urea, HDL, LDL and total cholesterol were predicted with relative errors between 15 and 32%. The analytical predicti…

ChemometricsAnalyteStandard errorChemistryCalibration (statistics)Attenuated total reflectionPrincipal component analysisPartial least squares regressionStatisticsSample (statistics)SpectroscopyAnalytical ChemistryMicrochemical Journal
researchProduct

Red Blood Cells Polarize Green Laser Light Revealing Hemoglobin's Enhanced Non-Fundamental Raman Modes

2014

In general, the first overtone modes produce weak bands that appear at approximately twice the wavenumber value of the fundamental transitions in vibrational spectra. Here, we report the existence of a series of enhanced non-fundamental bands in resonance Raman (RR) spectra recorded for hemoglobin (Hb) inside the highly concentrated heme environment of the red blood cell (RBC) by exciting with a 514.5 nm laser line. Such bands are most intense when detecting parallel-polarized light. The enhancement is explained through excitonic theory invoking a type C scattering mechanism and bands have been assigned to overtone and combination bands based on symmetry arguments and polarization measureme…

ErythrocytesOvertonePlasmodium falciparumAnalytical chemistryporphyrinoidsmalaria diagnosticHemeSpectrum Analysis RamanMolecular physicsSpectral linelaw.inventionchemistry.chemical_compoundsymbols.namesakeHemoglobinslawHumansPhysical and Theoretical ChemistryMalaria FalciparumSpectroscopyHemeScatteringLasersArticlesLaserPolarization (waves)Atomic and Molecular Physics and OpticschemistryRaman spectroscopysymbolsRaman spectroscopyovertone/combination modesred blood cellsChemphyschem
researchProduct

Modified locally weighted—Partial least squares regression improving clinical predictions from infrared spectra of human serum samples

2012

Locally weighted partial least squares regression (LW-PLSR) has been applied to the determination of four clinical parameters in human serum samples (total protein, triglyceride, glucose and urea contents) by Fourier transform infrared (FTIR) spectroscopy. Classical LW-PLSR models were constructed using different spectral regions. For the selection of parameters by LW-PLSR modeling, a multi-parametric study was carried out employing the minimum root-mean square error of cross validation (RMSCV) as objective function. In order to overcome the effect of strong matrix interferences on the predictive accuracy of LW-PLSR models, this work focuses on sample selection. Accordingly, a novel strateg…

Blood GlucoseAnalyteChemistryBlood ProteinsCross-validationAnalytical ChemistryChemometricsMatrix (chemical analysis)symbols.namesakeFourier transformSpectroscopy Fourier Transform InfraredPartial least squares regressionPrincipal component analysisStatisticssymbolsHumansUreaLeast-Squares AnalysisFourier transform infrared spectroscopyBiological systemTriglyceridesTalanta
researchProduct

Short syntheses of (+)-ferruginol from (+)-dehydroabietylamine

2012

Short syntheses of bioactive (+)-ferruginol in five or six synthetic steps starting from commercially available (+)-dehydroabietylamine are described. The oxygenated function at C12 was introduced via a Friedel–Crafts acylation of N-phthaloyldehydroabietylamine followed by Baeyer–Villiger oxidation. Then, overall deprotection of functional groups, reductive deamination or biomimetic oxidative deamination, and final Wolff–Kishner reduction provided (+)-ferruginol in 21 and 23% overall yields, respectively.

FerruginolAcylationchemistry.chemical_compoundchemistryOrganic ChemistryDrug DiscoveryDeaminationOrganic chemistryOxidative deaminationDiterpeneBiochemistryChemical synthesisTetrahedron
researchProduct

Towards a Rapid Screening of Liver Grafts at the Operating Room Using Mid-Infrared Spectroscopy

2020

The estimation of steatosis in a liver graft is mandatory prior to liver transplantation, as the risk of graft failure increases with the level of infiltrated fat. However, the assessment of liver steatosis before transplantation is typically based on a qualitative or semiquantitative characterization by visual inspection and palpation and histological analysis. Thus, there is an unmet need for transplantation surgeons to have access to a diagnostic tool enabling an in situ fast classification of grafts prior to extraction. In this study, we have assessed an attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopic method compatible with the requirements of an operatio…

medicine.medical_specialtyOperating RoomsGraft failureTime FactorsSpectrophotometry Infraredmedicine.medical_treatmentgraft failureassessmentLiver transplantation010402 general chemistry01 natural sciencesPalpationMid infrared spectroscopyAnalytical Chemistryliver steatosisLiver steatosisstomatognathic systemliver graftmedicinesteatosisHumansmedicine.diagnostic_testliver transplantationChemistryPhysics010401 analytical chemistrymedicine.disease0104 chemical sciences3. Good healthLiver TransplantationLiver graftTransplantationAtomic Molecular and Optical Physicslipids (amino acids peptides and proteins)RadiologySteatosisinfiltrated fat
researchProduct

ATR-FTIR spectroscopy as a quality control system for monitoring the storage of blood products

2021

Blood screening is a fundamental part of disease diagnosis and monitoring health. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy offers an innovative solution to streamlining the process, especially for multianalyte detection in aqueous samples. However, samples always undergo a storage phase before they are processed for testing and blood transfusion. In this study, we investigated the effect of standard storage procedures on the macromolecular composition of whole blood, and plasma collected in blood tubes for diagnostic purposes and initial screening of blood products. Periphery blood samples were collected from 10 volunteers and then stored for 14 days a…

Quality ControlErythrocytesBlood transfusionResolution (mass spectrometry)General Chemical Engineeringmedicine.medical_treatmentInfrared spectroscopyAtaxia Telangiectasia Mutated Proteins01 natural sciencesAnalytical Chemistry03 medical and health sciencesSpectroscopy Fourier Transform InfraredPartial least squares regressionmedicineHumansLeast-Squares Analysis030304 developmental biologyWhole bloodBlood Specimen Collection0303 health sciencesChromatographyFourier AnalysisChemistry010401 analytical chemistryGeneral EngineeringBlood Screening0104 chemical sciencesBloodQuality control systemAttenuated total reflectionAnalytical Methods
researchProduct

Infrared-based quantification of clinical parameters

2014

Abstract Infrared (IR) spectroscopy has become a promising technique for the analysis of clinical samples, and IR-based diagnosis is already a well-established technique in the academic field. This review aims to report the methodologies proposed for IR quantification of different analytes and parameters in a variety of clinical samples; including: liquids, such as whole blood, serum, plasma, urine, human milk, amniotic fluid and cerebrospinal fluid; solids, such as urinary stones, skin, hair and lips; breath; or, microscopic quantifications on tissues. For the application of IR spectroscopy to the clinical field, we also discuss: the benefits, which make IR spectroscopy ideally suited to m…

ChemometricsModern medicineAnalyteInfraredChemistryAnalytical chemistryInfrared spectroscopySpectroscopySpectroscopyAnalytical ChemistryBiomedical engineeringTrAC Trends in Analytical Chemistry
researchProduct

Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors

2014

Selected volatile organic compounds (VOCs) in breath may be considered biomarkers if they are indicative of distinct diseases or disease states. Given the inherent molecular selectivity of vibrational spectroscopy, infrared sensing technologies appear ideally suitable for the determination of endogenous VOCs in breath. The aim of this study was to determine that mid-infrared (MIR; 3-20 µm) gas phase sensing is capable of determining isoprene in exhaled breath as an exemplary medically relevant VOC by hyphenating novel substrate-integrated hollow waveguides (iHWG) with a likewise miniaturized preconcentration system. A compact preconcentrator column for sampling isoprene from exhaled breath …

Pulmonary and Respiratory MedicineDetection limitTime FactorsInfrared RaysTemperatureAnalytical chemistryInfrared spectroscopySignal Processing Computer-AssistedBiosensing TechniquesSubstrate (electronics)Reference StandardsHollow waveguidechemistry.chemical_compoundHemiterpenesBreath TestsBreath gas analysischemistryPentanesTemporal resolutionCalibrationButadienesCalibrationHumansIsopreneJournal of Breath Research
researchProduct

Towards the Point of Care and Noninvasive Classification of Bladder Cancer from Urine Sediment Infrared Spectroscopy. Spectral differentiation of nor…

2021

Abstract Bladder cancer (BC) is the 9th cancer cause of death and one of most cost-intensive in the world. The diagnostic tools are still not at all satisfactory. Herein we evaluated the potential of infrared spectroscopy to detect molecular changes that precede and accompany the carcinogenesis in voided urine sediment. We collected 165 samples from patients being diagnosed for BC and measured them with attenuated total reflectance Fourier transformed infrared spectroscopy (ATR FTIR). Samples were primarily divided into three groups according to cytology that indicated the presence of normal, abnormal and cancer cells. ATR FTIR spectra of sediments were analyzed with the use of partial leas…

medicine.medical_specialtyInfrared spectroscopy02 engineering and technology01 natural sciencesGastroenterologyAnalytical ChemistryInternal medicineCytologyurine sedimentmedicineMedicine and Health Sciencesreflection (ATR)infrared spectroscopySpectroscopyBladder cancerbusiness.industry010401 analytical chemistryCancerHistologyGold standard (test)Point-of-Care analysis021001 nanoscience & nanotechnologymedicine.disease3. Good health0104 chemical sciencesAttenuated total reflectionCancer cellbladder cancer0210 nano-technologybusiness
researchProduct

Assessment of the statistical significance of classifications in infrared spectroscopy based diagnostic models.

2014

Fourier transform infrared (IR) spectroscopy in combination with multivariate data analysis is a versatile tool that can be applied to disease diagnosis. However, a rigorous validation of the obtained models is necessary in order to obtain robust results. This work evaluates the advantages of the use of permutation testing for determining the statistical significance of the misclassification errors obtained from IR based diagnostic models through cross validation (CV). The model performance, estimated by CV, is compared to a distribution of CV-performance values obtained using randomly permuted class labels. The distribution of ‘random CV-values’ is considered as a null distribution and use…

Multivariate analysisFeature selectionClinical Chemistry Tests02 engineering and technology01 natural sciencesBiochemistryCross-validationAnalytical ChemistryResamplingStatisticsDiagnosisSpectroscopy Fourier Transform InfraredElectrochemistryNull distributionEnvironmental ChemistryHumansSpectroscopyMathematicsModels Statistical010401 analytical chemistryEstimatorContrast (statistics)Discriminant AnalysisReproducibility of Results021001 nanoscience & nanotechnology0104 chemical sciencesRandom forest0210 nano-technologyThe Analyst
researchProduct

Materials and methods of signal enhancement for spectroscopic whole blood analysis: Novel research overview

2017

Abstract The early diagnosis of diseases is crucial for reducing morbidity and mortality and also for improving the quality of treatment process. Among various biological samples used to follow up the concentrations of disease markers, whole blood sensing can efficiently decrease analysis time by means of introducing methods with no pretreatment. In addition, the direct detection of markers in whole blood facilitates testing procedure and minimize the possibility of the loss of analytes in the process. Therefore, the assay of unprocessed whole blood is becoming increasingly important in clinical diagnostics and biomedical research. Incorporation of new advanced materials plays a major role …

AnalyteComputer science010401 analytical chemistryTreatment processNanotechnology02 engineering and technologyAdvanced materials021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesAnalytical ChemistrySignal enhancementOptical sensingDisease markers0210 nano-technologySpectroscopyBiomedical engineeringPoint of careWhole bloodTrAC Trends in Analytical Chemistry
researchProduct

Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.

2014

Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method d…

ChromatographyPlasma samplesChemistryPlasma compositionIon suppression in liquid chromatography–mass spectrometryBlood ProteinsMass spectrometryMethod developmentMass SpectrometryAnalytical ChemistryMice Inbred C57BLExploratory data analysisMetabolomicsSpectroscopy Fourier Transform InfraredAnimalsMetabolomicsSample preparationFemaleChromatography LiquidTalanta
researchProduct

Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts

2013

Attenuated total reflectance (ATR) infrared spectroscopy of dried organic extracts of serum samples has been evaluated as a fast method for the determination of triglycerides, cholesterol, high density lipoprotein (HDL) and low density lipoprotein (LDL). After careful selection of solvents based on green parameters, serum samples were extracted using hexane-isopropanol and ethyl acetate-ethanol mixtures. Microscopy studies and comparison with standard spectra were performed in order to investigate whether the proposed methodology is suitable for the quantification of lipids in serum samples. The results of these preliminary studies confirmed that the variations in the IR spectra of sample e…

AnalyteChromatographySpectrophotometry InfraredCholesterolCholesterol HDLExtraction (chemistry)Analytical chemistryInfrared spectroscopyCholesterol LDLBiochemistryAnalytical ChemistrySolventchemistry.chemical_compoundchemistryLow-density lipoproteinAttenuated total reflectionSpectroscopy Fourier Transform InfraredPartial least squares regressionSolventsElectrochemistryHumansEnvironmental ChemistryTriglyceridesSpectroscopyThe Analyst
researchProduct

Synthesis and biological evaluation of dehydroabietic acid derivatives.

2010

A series of C18-oxygenated derivatives of dehydroabietic acid were synthesized from commercial abietic acid and evaluated for their cytotoxic, antimycotic, and antiviral activities.

KetoneAntifungal AgentsCarboxylic acidAntineoplastic AgentsHerpesvirus 1 HumanMicrobial Sensitivity TestsAldehydeChemical synthesisAntiviral Agentschemistry.chemical_compoundInhibitory Concentration 50Cell Line TumorDrug DiscoveryOrganic chemistryAnimalsHumansAbietic acidCytotoxicityPharmacologychemistry.chemical_classificationOrganic ChemistryFungifood and beveragesGeneral Medicineequipment and suppliesTerpenoidchemistryAbietaneslipids (amino acids peptides and proteins)DiterpeneHydrophobic and Hydrophilic InteractionsEuropean journal of medicinal chemistry
researchProduct

Infrared based saliva screening test for COVID‐19

2021

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in an unprecedented need for diagnostic testing that is critical in controlling the spread of COVID-19. We propose a portable infrared spectrometer with purpose-built transflection accessory for rapid point-of-care detection of COVID-19 markers in saliva. Initially, purified virion particles were characterized with Raman spectroscopy, synchrotron infrared (IR) and AFM-IR. A data set comprising 171 transflection infrared spectra from 29 subjects testing positive for SARS-CoV-2 by RT-qPCR and 28 testing negative, was modeled using Monte Carlo Double Cross Validation with 50 randomized test and model sets. The testing se…

SalivaMaterials scienceCoronavirus disease 2019 (COVID-19)Spectrophotometry InfraredInfraredPoint-of-care testingInfrared spectroscopy010402 general chemistry01 natural sciencesProof of Concept StudySensitivity and SpecificityCatalysisSpecimen HandlingCohort Studies03 medical and health sciences0302 clinical medicineCOVID-19 TestingSpectrophotometryChlorocebus aethiopsmedicineCOVID-19 diagnostic infrared spectroscopy Raman spectroscopy saliva SARS-CoV-2 virionsAnimalsHumansQDLeast-Squares AnalysisSalivaVero CellsMass screening030304 developmental biologyDetection limit0303 health sciencessalivaChromatographymedicine.diagnostic_test010405 organic chemistrySARS-CoV-2COVID-19Discriminant AnalysisGeneral Chemistry030206 dentistryGeneral Medicine0104 chemical sciences3. Good healthPoint-of-Care TestingMonte Carlo MethodATR-FTIRResearch ArticleAngewandte Chemie (International Ed. in English)
researchProduct

Analysis of multi-source metabolomic data using joint and individual variation explained (JIVE).

2015

Metabolic profiling is increasingly being used for understanding biological processes but there is no single analytical technique that provides a complete quantitative or qualitative profiling of the metabolome. Data fusion (i.e. joint analysis of data from multiple sources) has the potential to circumvent this issue facilitating knowledge discovery and reliable biomarker identification. Another field of application of data fusion is the simultaneous analysis of metabolomic changes through several biofluids or tissues. However, metabolomics typically deals with large datasets, with hundreds to thousands of variables and the identification of shared and individual factors or structures acros…

Data sourceComputer scienceAnalytical techniqueStatistics as TopicAnalytical chemistryUrinalysisSensor fusioncomputer.software_genreBiochemistryAnalytical ChemistryMultiple dataMetabolomicsKnowledge extractionElectrochemistryEnvironmental ChemistryProfiling (information science)HumansMetabolomicsData miningcomputerSpectroscopyMulti-sourceBlood Chemical AnalysisSoftwareThe Analyst
researchProduct

Comparison of transflection and transmission FTIR imaging measurements performed on differentially fixed tissue sections

2015

The widespread and cost-effective use of transflection substrates in Fourier transform infrared (FTIR) imaging of clinical samples is affected by the presence of artefacts including the electric field standing wave (EFSW) and contributions from light dispersion. For IR-based diagnostics, the manifestation of undesirable artifacts can distort the spectra and lead to erroneous diagnosis. Nevertheless, there is no clear consensus in the literature about the degree of influence of these effects. The aim of this work is to contribute to this discussion by comparing transflection and transmission images of the same tissue. For this purpose two adjacent sections of the same tissue (lymphoma sample…

Tissue FixationLymphomaChemistryOptical ImagingAnalytical chemistryHyperspectral imagingBiochemistryAnalytical ChemistryAbsorbancesymbols.namesakeNuclear magnetic resonanceTissue sectionsFourier transformTransmission (telecommunications)Light dispersionSpectroscopy Fourier Transform InfraredElectrochemistrysymbolsEnvironmental ChemistryImage acquisitionFourier transform infrared spectroscopyArtifactsSpectroscopy
researchProduct

Cytotoxic, immunomodulatory, antimycotic, and antiviral activities of semisynthetic 14-hydroxyabietane derivatives and triptoquinone C-4 epimers

2013

A series of C14-hydroxy derivatives of dehydroabietic acid were synthesised from commercial abietic acid and evaluated for their cytotoxic, antimycotic, and antiviral activities. From these C14-hydroxy derivatives, triptoquinone C-4 epimers were obtained and their immunomodulatory activity was additionally evaluated. None of the tested compounds showed antiviral activity against herpes simplex virus type 1 (HHV-1), and nor did they display antimycotic activity against certain Aspergillus, spp. except for one compound, abieta-8,11,13-trien-14,18-diol. Interestingly, two triptoquinone epimers showed cytotoxic activity, and one of them induced mitochondrial potential loss, DNA damage and cell …

PharmacologyDNA damagemedicine.medical_treatmentMonocyteOrganic ChemistryPharmaceutical ScienceBiologyCell cyclemedicine.disease_causeBiochemistryPeripheral blood mononuclear cellJurkat cellsHerpes simplex virusCytokinemedicine.anatomical_structureBiochemistryDrug DiscoverymedicineMolecular MedicineCytotoxic T cellMedChemComm
researchProduct

ATR-FTIR spectroscopy for the routine quality control of exosome isolations

2021

Abstract Exosomes are nanosized vesicles containing specific cargos of DNA, RNA, proteins, metabolites, and intracellular and membrane lipids. Exosome isolation needs to be optimized carefully depending on the type of biofluid and tissue and the retrieved exosomes need to be characterized. The main objective of this study was to determine the feasibility of a multimodal analysis of Attenuated Total Reflectance – Fourier Transform Infrared (ATR-FTIR) spectroscopy and UPLC–QqTOF-MSMS for the development of a routine quality control tool of isolated exosomes and the rapid characterization of their lipid profiles and total protein content. Using human milk as model example, exosomes were isolat…

Fourier transform infrared (ATR-FTIR)Membrane lipidsOmicsExosomes01 natural sciencesExosomeAnalytical Chemistry03 medical and health sciencesstomatognathic systemMETLINSpectroscopy030304 developmental biology0303 health sciencesChemistryProcess Chemistry and TechnologyVesicleHuman milk010401 analytical chemistryExtracellular vesiclesSphingolipidMicrovesicles0104 chemical sciencesComputer Science ApplicationsBiochemistryAttenuated total reflectionLipidomicslipids (amino acids peptides and proteins)UltracentrifugeAttenuated total reflectanceSoftwareChemometrics and Intelligent Laboratory Systems
researchProduct

Data set: Towards a rapid screening of liver grafts at the operating room using mid-infrared spectroscopy

2020

The estimation of steatosis in a liver graft is mandatory prior to liver transplantation, as the risk of graft failure increases with the level of infiltrated fat. However, the assessment of liver steatosis before transplantation is typically based on a qualitative or semi-quantitative characterization by visual inspection and palpation, and histological analysis. Thus, there is an unmet need for transplantation surgeons to have access to a diagnostic tool enabling an in situ fast classification of grafts prior extraction. In this study, we have assessed an Attenuated Total Reflection-Fourier Transform Infrared (ATR-FTIR) spectroscopic method compatible with the requirements of an operation…

stomatognathic systemliquid chromatography – mass spectrometrysteatosislipidomicsliverinfrared spectroscopy3. Good healthATR-FTIR
researchProduct

Data set: Towards a rapid screening of liver grafts at the operating room using mid-infrared spectroscopy

2020

The estimation of steatosis in a liver graft is mandatory prior to liver transplantation, as the risk of graft failure increases with the level of infiltrated fat. However, the assessment of liver steatosis before transplantation is typically based on a qualitative or semi-quantitative characterization by visual inspection and palpation, and histological analysis. Thus, there is an unmet need for transplantation surgeons to have access to a diagnostic tool enabling an in situ fast classification of grafts prior extraction. In this study, we have assessed an Attenuated Total Reflection-Fourier Transform Infrared (ATR-FTIR) spectroscopic method compatible with the requirements of an operation…

stomatognathic systemliquid chromatography – mass spectrometrysteatosislipidomicsliverinfrared spectroscopyATR-FTIR
researchProduct

Data set: Towards a rapid screening of liver grafts at the operating room using mid-infrared spectroscopy

2020

The estimation of steatosis in a liver graft is mandatory prior to liver transplantation, as the risk of graft failure increases with the level of infiltrated fat. However, the assessment of liver steatosis before transplantation is typically based on a qualitative or semi-quantitative characterization by visual inspection and palpation, and histological analysis. Thus, there is an unmet need for transplantation surgeons to have access to a diagnostic tool enabling an in situ fast classification of grafts prior extraction. In this study, we have assessed an Attenuated Total Reflection-Fourier Transform Infrared (ATR-FTIR) spectroscopic method compatible with the requirements of an operation…

stomatognathic systemliquid chromatography – mass spectrometrysteatosislipidomicsliverinfrared spectroscopy3. Good healthATR-FTIR