Targeting Moderate and Severe Male Stress Urinary Incontinence With Adjustable Male Slings and the Perineal Artificial Urinary Sphincter: Focus on Perioperative Complications and Device Explantations.
Purpose: To analyze perioperative complications and postoperative explantation rates for selected readjustable male sling systems and the perineal single-cuff artificial urinary sphincter (AUS) in a large, contemporary, multi-institutional patient cohort. Methods: Two hundred eighty-two male patients who underwent implantation between 2010 and 2012 in 13 participating institutions were included in the study (n = 127 adjustable male sling [n = 95 Argus classic, n = 32 Argus T], n = 155 AUS). Perioperative characteristics and postoperative complications were analyzed. The explantation rates of the respective devices were assessed using the Fisher exact test and the Mann-Whitney U-test. A Kapl…
The TiLOOP® Male Sling: Did We Forejudge.
<b><i>Introduction:</i></b> To evaluate the safety and efficacy of the TiLOOP® male sling (pfm medical, Cologne, Germany) used in the treatment for male stress urinary incontinence (SUI). <b><i>Material and Methods:</i></b> We retrospectively evaluated a total of 34 patients with a TiLOOP® male sling. Perioperative complication rates were assessed and validated questionnaires were prospectively evaluated to assess quality of life and satisfaction rate. Outcome and complication rates were analysed by using descriptive statistics. Correlation of continence outcome and risk factors was performed with the chi-square test. A <i>p</i> va…
High/low-volume center experience predicts outcome of AMS 800 in male stress incontinence: Results of a large middle European multicenter case series.
AIM To analyze the influence of implantation volume of artificial sphincters (AMS 800) on outcome in a large central European multicenter cohort study. METHODS As part of the DOMINO (Debates on Male Incontinence) project, the surgical procedures and outcomes were retrospectively analyzed in a total of 473 patients who received an artificial sphincter (AMS 800) between 2010 and 2012. Clinics that implanted at least 10 AMS 800 per year were defined as high-volume centers. RESULTS Sixteen centers had a mean rate of 9.54 AMS 800/y of which five clinics were identified as high-volume centers. They implanted significantly more double cuffs (55% vs 12.1%; P < .001), used the perineal approach sign…
European consensus conference on diagnosis and treatment of germ cell cancer: a report of the second meeting of the European Germ Cell Cancer Consensus group (EGCCCG): part I.
Objectives: The first consensus report presented by the European Germ Cell Cancer Consensus Group (EGCCCG) in the year 2004 has found widespread approval by many colleagues throughout the world. In November 2006, the group met a second time under the auspices of the Department of Urology of the Amsterdam Medical Center, Amsterdam, The Netherlands. Methods: Medical oncologists, urological surgeons, radiation oncologists as well as pathologists from several European countries reviewed and discussed the data that had emerged since the 2002 conference, and incorporated the new data into updated and revised guidelines. As for the first meeting, the methodology of evidence-based medicine (EBM) wa…
Risk Factors for Failure of Male Slings and Artificial Urinary Sphincters: Results from a Large Middle European Cohort Study.
<b><i>Introduction:</i></b> We analysed the impact of predefined risk factors: age, diabetes, history of pelvic irradiation, prior surgery for stress urinary incontinence (SUI), prior urethral stricture, additional procedure during SUI surgery, duration of incontinence, ASA-classification and cause for incontinence on failure and complications in male SUI surgery. <b><i>Materials and Methods:</i></b> We retrospectively identified 506 patients with an artificial urinary sphincter (AUS) and 513 patients with a male sling (MS) in a multicenter cohort study. Complication rates were correlated to the risk factors in univariate analysis. Subsequentl…
Artificial Urinary Sphincter Cuff Size Predicts Outcome in Male Patients Treated for Stress Incontinence: Results of a Large Central European Multicenter Cohort Study
Purpose The aim was to study the correlation between cuff size and outcome after implantation of an AMS 800 artificial urinary sphincter. Methods A total of 473 male patients with an AMS 800 sphincter implanted between 2012 and 2014 were analyzed in a retrospective multicenter cohort study performed as part of the Central European Debates on Male Incontinence (DOMINO) Project. Results Single cuffs were implanted in 54.5% and double cuffs in 45.5% of the patients. The cuffs used had a median circumference of 4.5 cm. Within a median follow of 18 months, urethral erosion occurred in 12.8% of the cases and was associated significantly more often with small cuff sizes (P<0.001). Multivariate ana…
Fixed or adjustable sling in the treatment of male stress urinary incontinence: results from a large cohort study
BACKGROUND: Fixed and adjustable male slings for the treatment of male urinary stress incontinence became increasingly popular during the last decade. Although fixed slings are recommended for the treatment of mild to moderate stress urinary incontinence, there is still a lack of evidence regarding the precise indication for an adjustable male sling. Furthermore, there is still no evidence that one type of male sling is superior to another. However, both, adjustable and fixed slings, are commonly utilized in daily clinical practice. This current investigation aims to evaluate the differences between fixed and adjustable male slings regarding indications, complication rates and functional ou…
Antibiotic Coating of the Artificial Urinary Sphincter (AMS 800): Is it Worthwhile?
Objective To investigate the impact of the antibiotic coating InhibiZone on the infection and explantation rates of the AMS 800 in comparison to the AMS 800 without InhibiZone. Materials and Methods We retrospectively identified 305 patients with an AMS 800 in a multicenter cohort study. Patients were subsequently divided into InhibiZone and without InhibiZone-coated groups. Infection and explantation rates were analyzed by univariate and consecutively by multivariate logistic regression adjusted to variable risk factors. The infection-free interval was estimated by Kaplan-Meier plot and compared by the log-rank test. A P value below .05 was considered statistically significant. Results We …
The impact of perioperative complications on favorable outcomes after artificial urinary sphincter implantation for post-prostatectomy incontinence
ABSTRACT Objective To investigate the effect of perioperative complications involving artificial urinary sphincter (AUS) implantation on rates of explantation and continence as well as health-related quality of life (HRQOL). Materials and methods Inclusion criteria encompassed non-neurogenic, moderate-to-severe stress urinary incontinence (SUI) post radical prostatectomy and primary implantation of an AUS performed by a high-volume surgeon (>100 previous implantations). Reporting complications followed the validated Clavien-Dindo scale and Martin criteria. HRQOL was assessed by the validated IQOL score, continence by the validated ICIQ-SF score. Statistical analysis included Chi (2) test, M…
The impact of perioperative complications on favorable outcomes after artificial urinary sphincter implantation for post-prostatectomy incontinence
ABSTRACT Objective To investigate the effect of perioperative complications involving artificial urinary sphincter (AUS) implantation on rates of explantation and continence as well as health-related quality of life (HRQOL). Materials and methods Inclusion criteria encompassed non-neurogenic, moderate-to-severe stress urinary incontinence (SUI) post radical prostatectomy and primary implantation of an AUS performed by a high-volume surgeon (>100 previous implantations). Reporting complications followed the validated Clavien-Dindo scale and Martin criteria. HRQOL was assessed by the validated IQOL score, continence by the validated ICIQ-SF score. Statistical analysis included Chi (2) test…