0000000000675085

AUTHOR

Antonino Rinaudo

showing 19 related works from this author

Modelling cardiac mechanics of left ventricular noncompaction

2020

Left ventricular noncompaction (LVNC) can be defined as a cardiomyopathy characterised by a pattern of prominent trabecular structure and deep intertrabecular recesses, that is thought to be caused by an arrest of normal endomyocardial morphogenesis. Using patient-specific computational modelling, we assessed the cardiac mechanics of five patients with LVNC and compared myocardial stress and pump performance to those of healthy controls. Findings shown that patients with LVNC have impaired left ventricular (LV) function, making it possible that the lack of fibre shortening of noncompacted layer can determine poor heart function. Pronounced end-systolic wall stress on left ventricular wall o…

medicine.medical_specialtygenetic structuresBiomedical EngineeringComputational MechanicsCardiomyopathy02 engineering and technology030218 nuclear medicine & medical imaging03 medical and health sciencesWall stress0302 clinical medicinecardiac mechanics finite element analysis Left ventricular noncompaction wall stressInternal medicine0202 electrical engineering electronic engineering information engineeringmedicineRadiology Nuclear Medicine and imagingbusiness.industryfungifood and beveragesmedicine.diseaseComputer Science ApplicationsCardiologyLeft ventricular noncompaction020201 artificial intelligence & image processingsense organsbusinessCardiac mechanics
researchProduct

Computational analysis to predict false-lumen perfusion and outcome of type B aortic dissection.

2014

We have attempted to identify potential predictors foracute and late aortic events starting from admission computed tomographic images.

Pulmonary and Respiratory Medicinemedicine.medical_specialtyFalse lumenPredictive Value of TestOutcome (game theory)Text miningImaging Three-DimensionalAneurysm DissectingPredictive Value of TestsInternal medicineMedicineHumansComputational analysisHemodynamicAortic Aneurysm Thoracicbusiness.industryType B aortic dissectionHemodynamicsModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeAortic DissectionTreatment OutcomeCardiologyRadiographic Image Interpretation Computer-AssistedSurgeryCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedPerfusionHumanThe Journal of thoracic and cardiovascular surgery
researchProduct

Regional variation of wall shear stress in ascending thoracic aortic aneurysms.

2014

The development of an ascending thoracic aortic aneurysm is likely caused by excessive hemodynamic loads exerted on the aneurysmal wall. Computational fluid-dynamic analyses were performed on patient-specific ascending thoracic aortic aneurysms obtained from patients with either bicuspid aortic valve or tricuspid aortic valve to evaluate hemodynamic and wall shear parameters, imparting aneurysm enlargement. Results showed an accelerated flow along the outer aortic wall with helical flow in the aneurysm center for bicuspid aortic valve ascending thoracic aortic aneurysms. In a different way, tricuspid aortic valve ascending thoracic aortic aneurysms exhibited normal systolic flow without su…

Computational fluid dynamics ascending thoracic aortic aneurysm bicuspid aortic valve wall shear stress hypertensionAortic valvemedicine.medical_specialtyAortabusiness.industryMechanical EngineeringSettore ING-IND/34 - Bioingegneria IndustrialeHemodynamicsGeneral Medicinemedicine.diseaseThoracic aortic aneurysmSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineBicuspid aortic valveAneurysmmedicine.anatomical_structuremedicine.arteryInternal medicinecardiovascular systemmedicineCardiologyShear stresscardiovascular diseasesbusinessHelical flowProceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
researchProduct

Evaluation of ventricular wall stress and cardiac function in patients with dilated cardiomyopathy

2015

Dilated cardiomyopathy is a heart disease characterized by both left ventricular dilatation and left ventricular systolic dysfunction, leading to cardiac remodeling and ultimately heart failure. We aimed to investigate the effect of dilated cardiomyopathy on the pump performance and myocardial wall mechanics using patient-specific finite element analysis. Results evinced pronounced end-systolic wall stress on left ventricular wall of patients with dilated cardiomyopathy as compared to that of normal hearts. In dilated cardiomyopathy, both end-diastolic and end-systolic pressure–volume relationships of left ventricle and right ventricle were shifted to the right compared to controls, sugges…

Cardiac function curveCardiomyopathy Dilatedmedicine.medical_specialtyHeart diseaseHeart VentriclesFinite Element AnalysisDilated cardiomyopathycardiac mechanicBlood PressureHeart VentricleContractilityCohort StudiesAfterloadInternal medicineMedicineHumansAgedbiologybusiness.industryMedicine (all)Mechanical EngineeringModels CardiovascularDilated cardiomyopathyHeartGeneral MedicineMiddle Agedmedicine.diseaseTroponinfinite element analysimedicine.anatomical_structureVentricleHeart failureCardiologybiology.proteinwall streCohort StudiebusinessHuman
researchProduct

Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid-structure interaction analysis

2013

We present preliminary data on the flow-induced haemodynamic and structural loads exerted on a penetrating atherosclerotic aortic ulcer (PAU). Specifically, one-way fluid-structure interaction analysis was performed on the aortic model reconstructed from a 66-year-old male patient with a PAU that evolved into an intramural haematoma and rupture of the thoracic aorta. The results show that elevated blood pressure (117 mmHg) and low flow velocity at the aortic wall (0.15 m/s(2)) occurred in the region of the PAU. We also found a low value of time-averaged wall shear stress (1.24 N/m(2)) and a high value of the temporal oscillation in the wall shear stress (oscillatory shear index = 0.13) in t…

Malemedicine.medical_treatmentHemodynamicsAorta ThoracicMedicineThoracic aortaHematomamedicine.diagnostic_testEndovascular ProceduresModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeAnatomyTreatment OutcomeAtherosclerosiCardiologyWall shear streCardiology and Cardiovascular MedicineBrief CommunicationsBlood Flow VelocityHumanPulmonary and Respiratory Medicinemedicine.medical_specialtyAortographyAortic RuptureAortic DiseasesAortographyBlood Vessel Prosthesis ImplantationSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchinePenetrating atherosclerotic ulcerPenetrating atherosclerotic ulcerInternal medicinemedicine.arteryFluid-structure interactionShear stressHumansArterial PressureComputer SimulationHemodynamicAortic ruptureUlcerAgedEndovascular Procedurebusiness.industryHemodynamicsStentmedicine.diseaseAtherosclerosisAortic DiseaseBlood pressureRegional Blood FlowSurgeryStress MechanicalbusinessTomography X-Ray Computed
researchProduct

Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair

2015

Endografts placed in the aorta for thoracic endovascular aortic repair (TEVAR) may determine malappositioning to the lesser curvature of the aortic wall, thus resulting in a devastating complication known as endograft collapse. This premature device failure commonly occurs in young individuals after TEVAR for traumatic aortic injuries as a result of applications outside the physical conditions for which the endograft was designed. In this study, an experimentally-calibrated fluid-structure interaction (FSI) model was developed to assess the hemodynamic and stress/strain distributions acting on the excessive protrusion extension (PE) of endografts deployed in four young patients underwent TE…

AdultMaleAortic archmedicine.medical_specialtyHemodynamicsAorta ThoracicHealth InformaticsProsthesis DesignBlood Vessel Prosthesis ImplantationYoung AdultAortic aneurysmBlood vessel prosthesismedicine.arteryInternal medicineFluid-structure interactionStentHumansMedicineThoracic aortaStent-graftHemodynamicEndovascular ProcedureAortaAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresHemodynamicsmedicine.diseaseCurvatures of the stomachBlood Vessel ProsthesisComputer Science ApplicationsSurgeryAlgorithmRadiographyDescending aortaCalibrationCardiologyEndograft collapse/infoldingStentsStress MechanicalThoracic endovascular aortic repair (TEVAR)businessAlgorithmsBird-beakHumanComputers in Biology and Medicine
researchProduct

Computational fluid dynamics simulation to evaluate aortic coarctation gradient with contrast-enhanced CT

2014

Coarctation of aorta (CoA) is a narrowing of the aorta leading to a pressure gradient (Delta P) across the coarctation, increased afterload and reduced peripheral perfusion pressures. Indication to invasive treatment is based on values of maximal (systolic) trans-coarctation Delta P. A computational fluid dynamic (CFD) approach is herein presented for the non-invasive haemodynamic assessment of Delta P across CoA. Patient-specific CFD simulations were created from contrast-enhanced computed tomography (CT) and appropriate flow boundary conditions. Computed Delta P was validated with invasive intravascular trans-CoA pressure measurements. Haemodynamic indices, including pressure loss coeffic…

medicine.medical_specialtyBiomedical EngineeringHemodynamicsBioengineeringComputational fluid dynamicscontrast-enhanced computed tomographylaw.inventioncomputational fluid dynamicSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineAfterloadlawmedicine.arteryInternal medicinemedicineShear stressPressure gradientPressure dropAortabusiness.industryChemistrycoarctation of aortapressure gradientGeneral MedicineComputer Science ApplicationsHuman-Computer InteractionPressure measurementCardiologybusinessComputer Methods in Biomechanics and Biomedical Engineering
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Predicting Outcome of Aortic Dissection with Patent False Lumen by Computational Flow Analysis

2014

Although Type B aortic dissection (AoD) has better in-hospital survival than Type A AoD, the short- and long term outcome for patients remains challenging, with 50–80% deaths at 5-years. Dissection-related complications include rapid aortic expansion, impending rupture, and malperfusion syndromes. We aimed to assess hemodynamic implications of patients with patent false lumen (FL) of dissected aorta. Computational fluid dynamic analyses were performed on patient-specific aortic geometries reconstructed from computed tomography scans of 25 patients with AoDs, who were admitted in our hospital from 2007 to 2013. We used the development of acute complications and chronic aneurysmal evolution a…

Aortic dissectionAortamedicine.medical_specialtyFlowbusiness.industryBiomedical EngineeringFalse LumenHemodynamicsBlood flowmedicine.diseaseType B Aortic DissectionSurgerySettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineBlood pressuremedicine.arteryInternal medicineLinear regressionmedicineCardiologyTearsCFDCardiology and Cardiovascular MedicineAdverse effectbusinessCardiovascular Engineering and Technology
researchProduct

Difference in hemodynamic and wall stress of ascending thoracic aortic aneurysms with bicuspid and tricuspid aortic valve.

2012

The aortic dissection (AoD) of an ascending thoracic aortic aneurysm (ATAA) initiates when the hemodynamic loads exerted on the aneurysmal wall overcome the adhesive forces holding the elastic layers together. Parallel coupled, two-way fluid–structure interaction (FSI) analyses were performed on patient-specific ATAAs obtained from patients with either bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) to evaluate hemodynamic predictors and wall stresses imparting aneurysm enlargement and AoD. Results showed a left-handed circumferential flow with slower-moving helical pattern in the aneurysm's center for BAV ATAAs whereas a slight deviation of the blood flow toward the anterolater…

Aortic valveMalemedicine.medical_specialtyFluid–structure interaction Aortic dissection Ascending thoracic aortic aneurysm Bicuspid aortic valveBiomedical EngineeringBiophysicsHeart Valve DiseasesAorta ThoracicThoracic aortic aneurysmArticleAortic aneurysmBicuspid aortic valveBicuspid Aortic Valve DiseaseInternal medicinemedicine.arteryCoronary CirculationAscending aortamedicineThoracic aortaHumansOrthopedics and Sports Medicinecardiovascular diseasesAgedAortic dissectionAortabusiness.industryRehabilitationHemodynamicsModels CardiovascularMiddle Agedmedicine.diseaseElasticityAortic Aneurysmmedicine.anatomical_structureAortic ValveCardiologycardiovascular systemFemaleTricuspid ValvebusinessJournal of biomechanics
researchProduct

Mechanics of pericardial effusion: A simulation study

2015

Pericardial effusion is a pathological accumulation of fluid within pericardial cavity, which may compress heart chambers with hemodynamic impairment. We sought to determine the mechanics underlying the physiology of the hemodynamic impairment due to pericardial effusion using patient-specific computational modeling. Computational models of left ventricle and right ventricle were based on magnetic resonance images obtained from patients with pericardial effusion and controls. Myocardial material parameters were adjusted, so that volumes of ventricular chambers and pericardial effusion agreed with magnetic resonance imaging data. End-diastolic and end-systolic pressure–volume relationships …

AdultMalemedicine.medical_specialtyFinite Element AnalysisDiastolePericardial effusionPericardial effusionYoung AdultSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineFinite Element AnalysiInternal medicineCardiac tamponademedicineSettore ING-IND/12 - Misure Meccaniche E TermichePericardiumHumansInterventricular septumcomputer modelingAgedAged 80 and overbusiness.industryMechanical EngineeringPericardial cavityModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeGeneral MedicineStroke volumeMechanicsmedicine.diseaseCardiac Tamponademedicine.anatomical_structureVentricleCardiologyFemaleRadiologybusinessHuman
researchProduct

Development of a self-pumping extracorporeal blood oxygenation device characterized by a rotating shaft with embedded fiber packages.

2019

Introduction: To offer respiratory support for patients with lung disease, a novel technological solution for blood pumping and oxygenation is being developed. The pump–lung system was designed to integrate fiber membranes into six packages radially embedded in a rotating hollow shaft placed along the longitudinal axis of the device. Fiber packages are inclined with respect to the rotation axis so that the rotational motion of the rotating shaft allows a self-pumping system to be obtained. Method: Both hemodynamic and gas transfer performances were investigated using both in vitro experiments and in silico flow analyses. Results: The predicted flow velocity in the pump chamber was smooth an…

Lung Diseaseslung disease0206 medical engineeringBiomedical EngineeringMedicine (miscellaneous)Bioengineering02 engineering and technology030204 cardiovascular system & hematologyHeart-Lung MachineExtracorporealArtificial lungBiomaterials03 medical and health sciences0302 clinical medicineMedicineHumansComputational analysisFiberLungartificial lungOxygenators Membranebusiness.industryRespiratory supportHemodynamicsGeneral MedicineOxygenationEquipment Design020601 biomedical engineeringRespiratory supportOxygencomputational analysiLung diseaseBlood oxygenationArtificial OrgansbusinessBiomedical engineeringThe International journal of artificial organs
researchProduct

STUDIO NUMERICO DELL'EMODINAMICA IN PAZIENTI CON DISSECAZIONE AORTICA DI TIPO B

2013

The development of type B aortic dissection (AoD) is caused by altered haemodynamic forces exerted on false and true lumina of dissected aorta. This work aims to study haemodynamic and morphological proprieties, which influence the progression or stability of type B AoD. Computational fluid-dynamic analyses were performed on three patients with type B AoD, whose two presented an aneurysm evolution and one presented no further complication connected with dissection. Blood flow features showed that the true lumen flow was laminar and uniform while false lumen flow lost the laminar characteristic with consequent vorticity formation. The entry point zone proximal to the aortic arch showed both …

Settore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineCFD dissecazione aortica Wall Shear Stress
researchProduct

AN IN-VITRO PHANTOM STUDY ON THE THORACIC AORTIC STENT GRAFT COLLAPSE RESULTING FROM A BIRD-BEAK CONFIGURATION INTO THE AORTIC ARCH

2014

Settore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineFSI Thoracic Aortic Stent Graft Aortic Coarctation
researchProduct

Cardiac Mechanics of Left Ventricular NonCompaction by Finite Element Modeling

2014

LVNC Finite Elements model
researchProduct

POLYSACCHARIDE-BASED HYDROGELS FOR MYOCARDIUM REMODELING

2014

HydrogelsSettore CHIM/07 - Fondamenti Chimici Delle Tecnologie
researchProduct

COMPUTATIONAL FLUID DYNAMICS OF TYPE B AORTIC DISSECTION

2014

Type B aortic dissection (AoD) is a disease connected to high blood load on the aortic wall and to a reduced aortic wall resistance. Nowadays, prognosis on type B AoD results to be particularly difficult with an high incidence of patients treated with medical therapy which manifest complication connected with dissection and which should have been treated with surgical repair immediately. This work aims to study those haemodynamical and morphological proprieties of dissected aorta, which can influence the progression or stability of type B AoD. Computational fluid-dynamic analyses were performed on twenty-five patients with type B AoD, whose nine presented an aneurysm evolution and sixteen p…

Aortic Dissection Computational Fluid Dynamics Entry Tear Height False Lumen FlowAortic Dissection Computational Fluid Dynamics Entry Tear Height False Lumen Flow
researchProduct

Influenza della Morfologia Funzionale della Valvola Aortica sull'Emodinamica di Pazienti con Aneurisma Toracico dell'Aorta Ascendente

2013

Il presente lavoro si propone di studiare le differenze emodinamiche e i carichi di parete che si sviluppano in pazienti con aneurisma toracico dell'aorta ascendente (ATAA) con differente morfologia della valvola aortica. Sono stati identificati 5 pazienti con ATAA sottoposti a scansione TC per il controllo del diametro dell'aneurisma presso l'Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione. In particolare, tre pazienti presentano valvola aortica di tipo tricuspide(TAV) mentre due valvola aortica di tipo bicuspide (BAV) generalmente associata alla formazione di ATAA. Sono state ricostruite le geometrie dei ATAA includendo anche la ricostruzione delle valvole aortich…

Settore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineAneurisma toracico ascendente fluidodinamica valvola aortica
researchProduct

Predicting Outcome of Type B Aortic Dissection with Patent False Lumen by Computational Flow Analysis

2014

Settore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineFlowFalse LumenCFDType B Aortic Dissection
researchProduct