0000000000873901

AUTHOR

Rajendra-prasad Pawar

showing 2 related works from this author

Use of Micellar Liquid Chromatography to Determine Mebendazole in Dairy Products and Breeding Waste from Bovine Animals

2020

Mebendazole is an anthelmintic drug used in cattle production. However, residues may occur in produced food and in excretions, jeopardizing population health. A method based on micellar liquid chromatography (MLC) was developed to determine mebendazole in dairy products (milk, cheese, butter, and curd) and nitrogenous waste (urine and dung) from bovine animals. Sample treatment was expedited to simple dilution or solid-to-liquid extraction, followed by filtration and direct injection of the obtained solution. The analyte was resolved from matrix compounds in less than 8 min, using a C18 column and a mobile phase made up of 0.15 M sodium dodecyl sulfate (SDS)&ndash

Microbiology (medical)Analytemicellar01 natural sciencesBiochemistryMicrobiologyArticleMatrix (chemical analysis)chemistry.chemical_compoundmedicinePharmacology (medical)AnthelminticGeneral Pharmacology Toxicology and PharmaceuticsSodium dodecyl sulfateDetection limitvalidationmilkChromatographyanthelmintic010405 organic chemistryfood010401 analytical chemistryExtraction (chemistry)lcsh:RM1-950food and beveragesurine0104 chemical sciencesDilutionInfectious Diseaseslcsh:Therapeutics. PharmacologychemistryMicellar liquid chromatographymedicine.drugAntibiotics
researchProduct

Determination of albendazole and ivermectin residues in cattle and poultry-derived samples from India by micellar liquid chromatography

2021

We have developed a method, based on micellar liquid chromatography, to determine albendazole and ivermectin in dairy products and biological waste from bovine, as well as edible tissues from poultry. Anthelmitics were resolved in less than 10 min using a C18 column and a mobile phase of 0.15 mol/L sodium dodecyl sulfate – 6% 1-pentanol at buffered at pH 7 with a 0.01 M phosphate salt, running under isocratic mode at 1 mL/min. Detection was by absorbance at 292 nm. Method was successfully validated following official validation guidelines, in terms of: selectivity, sensitivity, calibration range (0.0125−0.5 mg/kg to 25−50 mg/kg), linearity (r2 > 9990), trueness (86.3–105.6%), precision (<12…

chemistry.chemical_classificationbiological wasteChromatographyanthelminticmicellar liquid chromatographydairy productsfood analysisalbendazoledrug residueSalt (chemistry)PhosphateAlbendazoleivermectinAbsorbancechemistry.chemical_compoundIvermectinchemistryMicellar liquid chromatographyfood compositionmedicineAnthelminticSodium dodecyl sulfateedible tissuesFood Sciencemedicine.drugJournal of Food Composition and Analysis
researchProduct