0000000001297812

AUTHOR

José J. Esteve-taboada

Power profiles in multifocal contact lenses with variable multifocal zone

BACKGROUND The power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. METHODS The measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a functi…

research product

Amplitude, Latency, and Peak Velocity in Accommodation and Disaccommodation Dynamics

The aim of this work was to ascertain whether there are differences in amplitude, latency, and peak velocity of accommodation and disaccommodation responses when different analysis strategies are used to compute them, such as fitting different functions to the responses or for smoothing them prior to computing the parameters. Accommodation and disaccommodation responses from four subjects to pulse changes in demand were recorded by means of aberrometry. Three different strategies were followed to analyze such responses: fitting an exponential function to the experimental data; fitting a Boltzmann sigmoid function to the data; and smoothing the data. Amplitude, latency, and peak velocity of …

research product

Evaluation of the iridocorneal angle with accommodation using optical coherence tomography

The changes in the iridocorneal angle structure during accommodation are assessed by means of anterior segment optical coherence tomography. Thirteen right eyes were included in the study. The device used for the measurement was the Visante® omni system. The stimuli were set up at different vergences (0.0 D, -1.5 D, and -3.0 D). The angle opening distance 500 and 750, the trabecular iris space area 500 and 750, and the scleral spur angle parameters were assessed at the nasal and temporal regions. The results in the iridotrabecular angle comparing the three accommodative states of the eye did not yield any statistically significant difference at nasal or temporal angle sections. In light of …

research product

Effect of Phenylephrine on the Accommodative System

Accommodation is controlled by the action of the ciliary muscle and mediated primarily by parasympathetic input through postganglionic fibers that originate from neurons in the ciliary and pterygopalatine ganglia. During accommodation the pupil constricts to increase the depth of focus of the eye and improve retinal image quality. Researchers have traditionally faced the challenge of measuring the accommodative properties of the eye through a small pupil and thus have relied on pharmacological agents to dilate the pupil. Achieving pupil dilation (mydriasis) without affecting the accommodative ability of the eye (cycloplegia) could be useful in many clinical and research contexts. Phenylephr…

research product

Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity

Aim To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. Methods An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. Results The Sw was smaller …

research product

Avaliação por OCT in vivo do comprimentos axiais centrais do segmento anterior

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any s…

research product

Accommodation Responds to Optical Vergence and Not Defocus Blur Alone.

Purpose To determine whether changes in wavefront spherical curvature (optical vergence) are a directional cue for accommodation. Methods Nine subjects participated in this experiment. The accommodation response to a monochromatic target was measured continuously with a custom-made adaptive optics system while astigmatism and higher-order aberrations were corrected in real time. There were two experimental open-loop conditions: vergence-driven condition, where the deformable mirror provided sinusoidal changes in defocus at the retina between -1 and +1 diopters (D) at 0.2 Hz; and blur-driven condition, in which the level of defocus at the retina was always 0 D, but a sinusoidal defocus blur …

research product

There is more to accommodation of the eye than simply minimizing retinal blur

Eyes of children and young adults change their optical power to focus nearby objects at the retina. But does accommodation function by trial and error to minimize blur and maximize contrast as is generally accepted? Three experiments in monocular and monochromatic vision were performed under two conditions while aberrations were being corrected. In the first condition, feedback was available to the eye from both optical vergence and optical blur. In the second, feedback was only available from target blur. Accommodation was less precise for the second condition, suggesting that it is more than a trial-and-error function. Optical vergence itself seems to be an important cue for accommodation.

research product

Repeatability of in vitro power profile measurements for multifocal contact lenses

Abstract Purpose To evaluate the repeatability of an optical device (NIMO TR1504, Lambda-X, Belgium) for measuring multifocal contact lens power profiles. Methods The NIMO TR1504 was used to measure power profiles 30 times for each of 10 different contact lenses from 4 major companies. All contact lenses were labelled as −3 D for distance vision; half were for high addition and half for low addition. The optical zone in all measurements was set to 3-mm radius. For each lens, the median power profile and the residuals of the 30 measurements were calculated. The 95% confidence bands and two indices that summarize measurement errors were calculated: the repeatability limit and an index of repe…

research product

Influence of contrast polarity on the accommodative response☆

espanolObjetivo Evaluar los cambios de la respuesta acomodativa del ojo al leer un texto en diferentes condiciones de polaridad de contraste: letras negras sobre fondo blanco (condicion BoW) y letras blancas sobre fondo negro (condicion WoB). Metodos En este estudio experimental participaron dieciocho sujetos de edades comprendidas entre 21 y 41 anos. Se obtuvo objetivamente la respuesta acomodativa (AR) del ojo al leer un texto con polaridad de contraste BoW o WoB con un sistema de optica adaptativa que corregia todas las aberraciones salvo las propias del sujeto. Se estudiaron dos tamanos de letra diferentes (condiciones de agudeza visual), mostrados en una micropantalla. Se midio la AR d…

research product

Effect of Decentration on the Optical Quality of Two Intraocular Lenses

To analyze the effect of decentration on the optical quality of two diffractive-refractive intraocular lenses, a bifocal and a trifocal, when displaced laterally (horizontal direction) from the center.The AT LISA 809M IOL (+3.75 D add) with two main foci and the AT LISA tri 839MP intraocular lens with three main foci (Carl Zeiss Meditec AG, Jena, Germany) were analyzed. The optical quality of the intraocular lenses was measured with the PMTF (power and modulation transfer function [MTF] measurement for refractive and diffractive intraocular lenses) optical bench (Lambda-X, Nivelles, Belgium). The optical quality of the lenses was evaluated by the MTF at different object vergences, the avera…

research product

Opto-mechanical artificial eye with accommodative ability.

The purpose of this study was to describe the design and characterization of a new opto-mechanical artificial eye (OMAE) with accommodative ability. The OMAE design is based on a second-pass configuration where a small source of light is used at the artificial retina plane. A lens whose focal length can be changed electronically was used to add the accommodation capability. The changes in the OMAE's aberrations with the lens focal length, which effectively changes the accommodative state of the OMAE, were measured with a commercial aberrometer. Changes in power and aberrations with room temperature were also measured. The OMAE's higher-order aberrations (HOAs) were similar to the ones of th…

research product

Three-dimensional object recognition by Fourier transform profilometry

An automatic method for three-dimensional (3-D) shape recognition is proposed. It combines the Fourier transform profilometry technique with a real-time recognition setup such as the joint transform correlator (JTC). A grating is projected onto the object surface resulting in a distorted grating pattern. Since this pattern carries information about the depth and the shape of the object, their comparison provides a method for recognizing 3-D objects in real time. A two-cycle JTC is used for this purpose. Experimental results demonstrate the theory and show the utility of the new proposed method.

research product

Human eyes do not need monochromatic aberrations for dynamic accommodation

Purpose To determine if human accommodation uses the eye's own monochromatic aberrations to track dynamic accommodative stimuli. Methods Wavefront aberrations were measured while subjects monocularly viewed a monochromatic Maltese cross moving sinusoidally around 2D of accommodative demand with 1D amplitude at 0.2 Hz. The amplitude and phase (delay) of the accommodation response were compared to the actual vergence of the stimulus to obtain gain and temporal phase, calculated from wavefront aberrations recorded over time during experimental trials. The tested conditions were as follows: Correction of all the subject's aberrations except defocus (C); Correction of all the subject's aberratio…

research product

Two-dimensional optical wavelet decomposition with white-light illumination by wavelength multiplexing

We present a novel method for achieving in real time a two-dimensional optical wavelet decomposition with white-light illumination. The underlying idea of the suggested method is wavelength multiplexing. The information in the different wavelet components of an input object is transmitted simultaneously in different wavelengths and summed incoherently at the output plane. Experimental results show the utility of the new proposed method.

research product

Recognition of polychromatic three-dimensional objects

We propose to use optical multichannel correlation in various chromatic systems to obtain a setup for recognition of polychromatic three-dimensional (3-D) objects based on Fourier-transform profilometry. Because red-green-blue color components are not able to split the luminance information of objects in a defined component, when the 3-D objects are brighter than the reference objects the correlation result gives false alarms. We demonstrate that it is possible to use different color spaces that can split luminance from chromatic information to yield adequate recognition of polychromatic 3-D objects. We show experimental results that prove the utility of the proposed method.

research product

Shift- and scale-invariant recognition of contour objects with logarithmic radial harmonic filters.

The phase-only logarithmic radial harmonic (LRH) filter has been shown to be suitable for scale-invariant block object recognition. However, an important set of objects is the collection of contour functions that results from a digital edge extraction of the original block objects. These contour functions have a constant width that is independent of the scale of the original object. Therefore, since the energy of the contour objects decreases more slowly with the scale factor than does the energy of the block objects, the phase-only LRH filter has difficulties in the recognition tasks when these contour objects are used. We propose a modified LRH filter that permits the realization of a shi…

research product

Dynamic accommodation without feedback does not respond to isolated blur cues

Highlights • A new methodology is used to study a potential cue for dynamic accommodation. • We show that human accommodation is not driven correctly by defocus alone. • Accommodation is most efficient using changes in stimulus vergence with feedback.

research product

Effect of phenylephrine on static and dynamic accommodation

Purpose We tested the hypothesis that changes in accommodation after instillation of Phenylephrine Hydrochloride (PHCl) observed in some studies could be caused by changes in optics. Methods We performed two experiments to test the effects of PHCl on static and on dynamic accommodation in 8 and 6 subjects, respectively. Objective wavefront measurements were recorded of the static accommodation response to a stimulus at different distances or dynamic accommodation response to a sinusoidally moving stimulus (between 1 and 3 D of accommodative demand at 0.2 Hz). The responses were characterized using two methods: one that takes into account the mydriatic optical effects on the accommodation pr…

research product

Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography

ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …

research product

Estimation of the mechanical properties of the eye through the study of its vibrational modes.

Measuring the eye's mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral a…

research product

Computing variations of entropy and redundancy under nonlinear mappings not preserving the signal dimension: quantifying the efficiency of V1 cortex

In computational neuroscience, the Efficient Coding Hypothesis argues that the neural organization comes from the optimization of information-theoretic goals [Barlow Proc.Nat.Phys.Lab.59]. A way to confirm this requires the analysis of the statistical performance of biological systems that have not been statistically optimized [Renart et al. Science10, Malo&Laparra Neur.Comp.10, Foster JOSA18, Gomez-Villa&Malo J.Neurophysiol.19]. However, when analyzing the information-theoretic performance, cortical magnification in the retina-cortex pathway poses a theoretical problem. Cortical magnification stands for the increase the signal dimensionality [Cowey&Rolls Exp. Brain Res.74]. Conventional mo…

research product

Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients

The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.

research product

Accommodative stimulus-response curves to low-pass filtered natural images

To assess how the monocular steady-state accommodative stimulus-response curve is modified when viewing low-pass filtered natural images. Eighteen adult subjects participated in the study. The accommodative stimulus-response curve was objectively assessed by means of a Hartmann-Shack wavefront sensor. Measurements were taken at different accommodative demands. Target images were low-pass filtered versions of a natural image that were obtained applying different digital spatial filters that limited the spatial frequency content of the natural image. Cutoff spatial frequencies were set at 30, 21, and 15 cycles per degree (cy/deg). Mean data obtained for each target were fitted to linear model…

research product

Effect of even and odd-order aberrations on the accommodation response

Aim To investigate the potential effect that odd and even-order monochromatic aberrations may have on the accommodation response of the human eye. Methods Eight healthy subjects with astigmatism below 1 D, best corrected visual acuity 20/20 or better and normal findings in an ophthalmic examination were enrolled. An adaptive optics system was used in order to measure the accommodation response of the subjects' eyes under different conditions: with the natural aberrations being present, and with the odd and even-order aberrations being corrected. Three measurements of accommodation response were monocularly acquired at accommodation demands ranging from 0 to 4 D (0.5 D step). Results The acc…

research product

Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses

AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses. METHODS: Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed. RESULTS: The power distribution of the lenses was affected by pupil siz…

research product

Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…

research product

Retroespalhamento luminoso das córneas de pacientes com diabete melito dependente e não dependente de insulina: estudo piloto

ABSTRACT Purpose: To compare central corneal backscatter obtained from Scheimpflug images between patients with insulin-dependent and non-insulin-dependent diabetes mellitus (IDDM and NIDDM, respectively) and healthy controls. Methods: Seven patients with IDDM (7 eyes), eleven patients with NIDDM (11 eyes), and sixteen healthy subjects (16 eyes) were included in this pilot study. Scheimpflug imaging system (Pentacam, Oculus Inc., Germany) was used to obtain optical sections of the cornea. Seven meridians were analyzed for each eye, oriented from 70° to 110°. Optical density values for the central 3-mm and 5-mm zones of the cornea were obtained by image analysis using external software. Resu…

research product

Detection and orientation evaluation for three-dimensional objects

This paper presents a novel method for detection and orientation evaluation for three-dimensional (3-D) objects based on range images. It is based on the calculation of the phase Fourier transform of the 3-D object range image. The method permits the estimation of the angular position of the object. It works with rotations around an axis perpendicular to the line of sight, although it exhibits a certain nodding tolerance. Simulated results demonstrate the ability of the new introduced method.

research product

Schematic eye models to mimic the behavior of the accommodating human eye

A simplified version of the human eye is known as schematic eye model. Since the first attempts in the middle of the 19th century, numerous approaches describing new schematic eye models have been introduced. Some of them are able to describe the accommodation ability of the human eye. Accommodative schematic eyes could be of great interest since they are able to explain the functionality of the human eye and they can be easily used for different research purposes. Some of these include the design and testing of multifocal ophthalmic solutions, evaluation of the effect of optical aberrations on the retinal image quality, and study of the optical performance of the eye at different distances…

research product

Confocal scanning laser ophthalmoscopy versus modified conventional fundus camera for fundus autofluorescence.

Fundus autofluorescence (FAF) is a noninvasive imaging method to detect fundus endogenous fluorophores, mainly lipofuscin located in the retinal pigment epithelium (RPE). The FAF provides information about lipofuscin distribution and RPE health, and consequently an increased accumulation of lipofuscin has been correlated with ageing and development of certain retinal conditions. Areas covered: An exhaustive literature search in MEDLINE (via OVID) and PUBMED for articles related to ocular FAF in retinal diseases and different devices used for acquiring FAF imaging was conducted. Expert commentary: This review aims to show an overview about autofluorescence in the RPE and the main devices use…

research product

Agreement of white-to-white measurements with the IOLMaster 700, Atlas 9000, and Sirius systems

Current advances in ocular surgery require the evaluation of differences in automated white-to-white (WTW) measurements between systems. We aim to analyze three different commonly used devices in clinical practice: the IOLMaster 700, the Atlas 9000, and the Sirius.Ninety right eyes of ninety healthy subjects were included. Measurements of WTW distances were taken with each device for all subjects in the same session and by the same observer. Statistical comparison was carried out by means of the rANOVA procedure and the Bonferroni post-hoc test. In addition, the Bland-Altman analysis was applied in order to perform pairwise comparisons.Average WTW values obtained by the IOLMaster 700, the A…

research product

Optical quality comparison among different Boston contact lens materials.

BACKGROUND The aim was to assess the optical quality of four Boston contact lens materials with an optical device based on Schlieren interferometry. METHODS The NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to measure higher-order aberrations and their corresponding root mean square values of four different rigid gas permeable contact lenses made from four different Boston materials: EO, ES, XO and XO2 . For each lens, 30 measurements were performed with two optical apertures: 3.0 mm and 6.0 mm. The modulation transfer function, point spread function, Strehl ratio and a simulation of the image provided by the lens were computed from the Zernike coefficients measured up to the fourth or…

research product

Accommodation in human eye models: a comparison between the optical designs of Navarro, Arizona and Liou-Brennan.

Aim To simulate and compare accommodation in accommodative and non-accommodative human eye models. Methods Ray tracing and optical design program was used. Three eye models were designed and studied: the Navarro, the Arizona and the Liou-Brennan. In order to make the Navarro and Liou-Brennan models to accommodate, specific geometric parameters of the models were altered with values that were chosen from the literature. For the Arizona model, its' mathematical functions for accommodation were used for the same accommodative demands. The simulation included four distances of accommodation for each model: at infinity, 3, 1 and 0.5 m.The results were diffraction images of a "letter F" for graph…

research product

Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.

Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…

research product

Power Profiles and In Vitro Optical Quality of Scleral Contact Lenses: Effect of the Aperture and Power

To assess the power profile and in vitro optical quality of scleral contact lenses with different powers as a function of the optical aperture. The mini and semiscleral contact lenses (Procornea) were measured for five powers per design. The NIMO TR-1504 (Lambda-X) was used to assess the power profile and Zernike coefficients of each contact lens. Ten measurements per lens were taken at 3- and 6-mm apertures. Furthermore, the optical quality of each lens was described in Zernike coefficients, modulation transfer function, and point spread function (PSF). A convolution of each lens PSF with an eye-chart image was also computed. The optical power fluctuated less than 0.5 diopters (D) along th…

research product

How Do Different Digital Displays Affect the Ocular Surface?

Digital display use has been accepted as a contributing factor to dry eye disease. Nowadays, plenty of new models of digital displays have been developed, and the differences in their nature and the ways in which they are set and used may contribute to differences in the eye-related problems they cause.This study aimed to analyze the differences in ocular surface, tear film, and visual fatigue parameters after reading on different digital displays, with and without initial instillation of artificial tears.Thirty-one healthy individuals ranging in age from 20 to 26 years (mean ± standard deviation, 21.26 ± 1.73 years) were included in this prospective clinical study. Subjects' ocular surface…

research product

Extended scale-invariant pattern recognition with white-light illumination.

A previous method of obtaining scale-invariance detection with white-light illumination has been improved on. We were able to detect different scaled versions of the target up to a magnification factor equal to 2. We simultaneously detected several versions in the same scene, because each scale factor is codified in a different wavelength. Experimental results demonstrate the proposed technique and show the utility of the method.

research product

Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs

Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…

research product

Tolerance to rotation of toric monofocal and bifocal intraocular lenses. A theoretical study

Abstract This manuscript aims to evaluate the tolerance to rotation of a toric monofocal and a toric bifocal intraocular lenses with different cylinder powers. Theoretical designs based on wavefront aberrations were created to simulate a toric monofocal and a toric bifocal intraocular lens. Cylinder power ranged from −1 D to −6 D, in steps of −1 D. Tolerance to rotation was estimated by the visual Strehl ratio based on the optical transfer function (VSOTF) metric. Tolerance to rotation for both monofocal and bifocal intraocular lenses decreased when the cylinder power increased. For the bifocal design studied, the tolerance to rotation was larger for the near focus than for the far, however…

research product

Implantable collamer lens with central hole: 3-year follow-up.

Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain; 3School of Medicine, University of Oviedo, Oviedo, Spain Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia.Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of …

research product

Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer

Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…

research product

Light distortion of soft multifocal contact lenses with different pupil size and shape

Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…

research product

Avaliação da resposta de acomodação após tarefas visuais próximas usando diferentes dispositivos eletrônicos portáteis

ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…

research product

Pilot Study on Visual Function and Fundus Autofluorescence Assessment in Diabetic Patients.

Purpose. Evaluate optimized fundus autofluorescence (FAF) imaging in early stages of diabetic retinopathy (DR) and relate findings with conventional colour fundus imaging and visual function in diabetic patients and control subjects.Materials and Methods. FAF and colour images were obtained using the CR-2 Plus digital nonmydriatic retinal camera in seven diabetic patients and thirteen control subjects. Visual-Functioning Questionnaire-25 (VFQ-25) and Diabetes Self-Management Questionnaire (DSMQ) were used to assess the quality of life and diabetes self-care. Contrast sensitivity function (CSF) was evaluated with the Vistech 6500 chart.Results. FAF and optimized-FAF imaging showed more retin…

research product

Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk

Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…

research product

Rotation-invariant optical recognition of three-dimensional objects.

An automatic method for rotation-invariant three-dimensional (3-D) object recognition is proposed. The method is based on the use of 3-D information contained in the deformed fringe pattern obtained when a grating is projected onto an object’s surface. The proposed method was optically implemented by means of a two-cycle joint transform correlator. The rotation invariance is achieved by means of encoding with the fringe pattern a single component of the circular-harmonic expansion derived from the target. Thus the method is invariant for rotations around the line of sight. The whole experimental setup can be constructed with simple equipment. Experimental results show the utility of the pro…

research product

Assessment of corneal thickness and tear meniscus during contact-lens wear

To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…

research product

Target localization in the three-dimensional space by wavelength multiplexing.

A method to localize a target in the three-dimensional space is presented. Each different position of the target on the depth axis produces, when captured with a CCD camera, an image of a different size on its sensor plane. The size of this image depends only on the distance between the target and the camera. The use of a white light optical correlator that gives us a different response depending on the scale of the input image permits us to know the depth position of the particular target. The obtained results demonstrate the utility of the newly proposed method.

research product

In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.

Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…

research product

Effect of age in the ciliary muscle during accommodation: Sectorial analysis

Abstract Purpose To compare changes in the ciliary muscle area at different sectors between pre-presbyopic and presbyopic eyes during accommodation by means of an anterior segment optical coherence tomographer (OCT). Methods The anterior ciliary muscle area was measured in 20 healthy and phakic pre-presbyopic eyes, whose mean age was 23.3 ± 4.4 years, and in 20 healthy and phakic presbyopic eyes, whose mean age was 46.5 ± 5.2 years. The relative change in the cross-sectional area of the ciliary muscle was measured at the nasal, inferior, and temporal sectors between 0 and −3 D of vergence, in −1 D step. A linear model was used to assess the correlation of each eye parameter with the accommo…

research product

Effect of Phenylephrine on the Accommodative System

Accommodation is controlled by the action of the ciliary muscle and mediated primarily by parasympathetic input through postganglionic fibers that originate from neurons in the ciliary and pterygopalatine ganglia. During accommodation the pupil constricts to increase the depth of focus of the eye and improve retinal image quality. Researchers have traditionally faced the challenge of measuring the accommodative properties of the eye through a small pupil and thus have relied on pharmacological agents to dilate the pupil. Achieving pupil dilation (mydriasis) without affecting the accommodative ability of the eye (cycloplegia) could be useful in many clinical and research contexts. Phenylephr…

research product

Assessing the accommodation response after near visual tasks using different handheld electronic devices

ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…

research product

Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…

research product

In vivo OCT assessment of anterior segment central axial lengths with accommodation

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any s…

research product