6533b823fe1ef96bd127df48

RESEARCH PRODUCT

Space Charge Effects in a Gas Filled Penning Trap

Natalis SeverijnsStefan SchwarzFriedhelm AmesD. BeckPaul SchuurmansB. DelauréMarcus BeckGeorg BollenO. ForstnerP. Schmidt

subject

Work (thermodynamics)ChemistrylawBuffer gasCyclotronIsobarIon trapAtomic physicsPenning trapSpace chargeIonlaw.invention

description

Mass selective buffer gas cooling is a technique used for ions that are stored in a Penning trap. The technique can be applied to all elements and the mass resolving power achieved has proven to be sufficient to resolve isobars. When not only a few but 106 and more ions are stored at the same time, space charge starts to play a dominant role for the spatial distribution. In addition, the observed cyclotron frequency is shifted. This work investigates these effects by numerical calculations.

https://doi.org/10.1007/978-94-015-1270-1_52