Search results for " Deriva"

showing 10 items of 718 documents

ChemInform Abstract: A Facile Route to New Potential Helicating Ligands.

2010

Abstract The synthesis of new bitriazolopyridines, 6,6′-disubstituted-2,2′-bipyridines and 2-pyridyl-6-(2-pyridylcarbonyl)-2-pyridylmethanone potential helicating ligands from 3-(2-aryl)-[1,2,3]triazolo[1,5-a]pyridines is described.

ChemistryTriazole derivativesOrganic chemistryGeneral MedicineChemInform
researchProduct

ChemInform Abstract: New Reactions of Vinylindoles as Heterocyclic Dienes with 4-Phenyl-1,2,4-triazoline-3,5-dione: Non-Concerted versus Concerted Pr…

2010

ChemistryTriazole derivativesOrganic chemistryGeneral MedicineChemInform
researchProduct

Synthesis of 3-triazenopyrroles

1993

Abstract The 3-triazenopyrroles, a new class of pyrrole derivatives, were synthesized in quantitative yield by coupling 3-diazopyrroles with secondary amines.

ChemistryYield (chemistry)Organic ChemistryOrganic chemistryCombinatorial chemistryPyrrole derivatives
researchProduct

Stereoselective synthesis of benzomorphan derivatives with perpivaloylated galactose as the chiral auxiliary.

2006

Chiral auxiliaryMolecular StructureStereochemistryEnantioselective synthesisOxazoloneGalactoseStereoisomerismGeneral ChemistryCatalysisCarbonchemistry.chemical_compoundBenzomorphanschemistryChloridesBenzomorphansGalactoseBenzomorphan derivativesStereoselectivityHydrogenAngewandte Chemie (International ed. in English)
researchProduct

Total Synthesis of (±)-Oxalicumone C and Chiral Resolution and Elucidation of Its Absolute Configuration

2014

The racemic total synthesis, the chiral resolution, and the elucidation of the absolute configuration of the natural product oxalicumone C were investigated. The goal was achieved by a synthetic strategy beginning with the synthesis of a 5-hydroxy-7-methylchromone precursor. Further modification possibilities were achieved by introduction of a vinyl moiety into the chromone, which was based on a selective iodination step in the 3-position. Further transformations furnished the racemic natural product. To determinate the absolute configuration of naturally occurring oxalicumone C, both enantiomers were separated by chiral HPLC. Comparison of the calculated and experimental vibrational circul…

Chiral column chromatographyCircular dichroismChemistryStereochemistryOrganic ChemistryVibrational circular dichroismAbsolute configurationTotal synthesisPhysical and Theoretical ChemistryEnantiomerChiral derivatizing agentChiral resolutionEuropean Journal of Organic Chemistry
researchProduct

Synthese von 2-Acyloxy- und 2-Alkyloxy-3-ketoglycalen und ihren Bromaddukten

1983

Die an den Hydroxygruppen acetyl-, pivaloyl- und methylgeschutzten 2-Hydroxy-3-ketoglycale 5a, 5b bzw. 11 werden durch Oxidation der entsprechenden 1-O-Acylglucopyranosen 3a, 3b bzw. 9 an der freien 3-Hydroxygruppe mit Dimethylsulfoxid/Acetanhydrid oder Chlorsulfonylisocyanat hergestellt und charakterisiert. Nur beim Acetylderivat 3a verlaufen die Oxidation und die Eliminierung des 1-Acetyloxysubstituenten in einem Schritt. Beim Pivaloylderivat 3b und beim Methylderivat 9 mus die Eliminierung aus der 3-Ulose 4 bzw. 10 mit Diazabicycloundecen (DBU) vervollstandigt werden. – Die geschutzten Hex-1-enopyran-3-ulosen 5a, 5b und 11 addieren Brom stereoselektiv unter Bildung der D-ribo-konfigurier…

Chlorosulfonyl isocyanateAnomerBromineDimethyl sulfoxideStereochemistryOrganic ChemistrySubstituentchemistry.chemical_elementAdductchemistry.chemical_compoundAcetic anhydridechemistryAcetyl derivativePhysical and Theoretical ChemistryLiebigs Annalen der Chemie
researchProduct

Approaches to characterise chromatographic column performance based on global parameters accounting for peak broadening and skewness.

2009

Peak broadening and skewness are fundamental parameters in chromatography, since they affect the resolution capability of a chromatographic column. A common practice to characterise chromatographic columns is to estimate the efficiency and asymmetry factor for the peaks of one or more solutes eluted at selected experimental conditions. This has the drawback that the extra-column contributions to the peak variance and skewness make the peak shape parameters depend on the retention time. We propose and discuss here the use of several approaches that allow the estimation of global parameters (non-dependent on the retention time) to describe the column performance. The global parameters arise f…

Chromatography Reverse-PhaseChromatographyAcetonitrilesResolution (mass spectrometry)ChemistryElutionOrganic ChemistryAdrenergic beta-AntagonistsLinear modelNormal DistributionGeneral MedicineReversed-phase chromatographyBiochemistryColumn (database)Standard deviationAnalytical ChemistryNormal distributionModels ChemicalSkewnessBenzene DerivativesLinear ModelsDiureticsJournal of chromatography. A
researchProduct

Development of the H-point standard additions method for coupled liquid chromatography and UV-visible spectrophotometry

1992

Abstract This work establishes the fundamentals of the H-point standard additions method for liquid chromatography for the simultaneous analysis of binary mixtures with overlapped chromatographic peaks. The method was compared with the deconvolution method of peak suppression and the second derivative of elution profiles. Different mixtures of diuretics were satisfactorily resolved.

Chromatographymedicine.diagnostic_testElutionChemistryAnalytical chemistryBiochemistryAnalytical ChemistrySpectrophotometryStandard additionmedicineEnvironmental ChemistryDeconvolutionSpectroscopySecond derivativeAnalytica Chimica Acta
researchProduct

Cisplatin derivative loaded in mesoporous MCM-41: preparation and characterization

2014

The aim of this study is to design and investigate a new material constituted by mesoporous silica MCM-41 and a new cisplatin derivative, cis-PtCl2(DMSO)HL]•2DMSO, where HL = 7-amino-2-(methylthio)[1,2,4]triazolo[1,5-a]pyrimidine-6-carboxylic acid, having biological activity.[1] The high surface area and the tunable pore size of MCM-41 allow it for loading vast amounts of bioactive molecules, including biocides and drugs. Mesoporous silica MCM-41 was prepared in alkaline environment from tetraethoxysilane as Si source and cetyltrimethylammonium bromide (CTAB) as template. [2] Amino groups have been successfully grafted onto the pore surface with 3-aminopropyl triethoxysilane (APTES) in orde…

Ciplatin derivatemesoporous silica MCM-41
researchProduct

Comparison of several methods used for the determination of cephalosporins. Analysis of cephalexin in pharmaceutical samples

2002

The precision of UV absorbance of intact and acid degraded cephalosporins, ninhydrin, high performance liquid chromatography and iodometric methods used for analysis of cefoxitin, cefotaxime, cephazolin and cephalexin were compared. To obtain the calibration graphs the analytical signal used were: absorbance, first derivative absorbance, second derivative absorbance and H-point Standard Additions Method by using absorbance values at two selected wavelengths as analytical signal. These methods and calibration graphs were also used for the determination of cephalexin in pharmaceutical samples.

Clinical BiochemistryPharmaceutical ScienceCapsulesHigh-performance liquid chromatographyAnalytical ChemistryAbsorbancechemistry.chemical_compoundIodometrySpectrophotometryDrug Discoverypolycyclic compoundsmedicineChromatography High Pressure LiquidSpectroscopyAntibacterial agentSecond derivativeCephalexinChromatographymedicine.diagnostic_testChemistrydigestive oral and skin physiologyTitrimetryNinhydrinCephalosporinsSolutionsStandard additionNinhydrinIndicators and ReagentsSpectrophotometry UltravioletJournal of Pharmaceutical and Biomedical Analysis
researchProduct