Search results for " Detection"
showing 10 items of 1676 documents
Detecting gravitational waves from cosmological phase transitions with LISA: an update
2020
MC was funded by the Royal Society under the Newton International Fellowship program. GD would like to thank CNPq (Brazil) for financial support. MH was supported by the Science and Technology Facilities Council (grant number ST/P000819/1), and the Academy of Finland (grant number 286769). SJH was supported by the Science and Technology Facilities Council (grant number ST/P000819/1). The work of JK was supported by Department of Energy (DOE) grant DE-SC0019195 and NSF grant PHY-1719642. TK and GS are funded by the Deutsche Forschungsgemeinschaft under Germany's Excellence Strategy - EXC 2121 \Quantum Universe" - 390833306. JMN is supported by Ramon y Cajal Fellowship contract RYC-2017-22986…
Novel Immune TiO2 Photoluminescence Biosensors for Leucosis Detection
2012
Abstract Novel immune photoluminescent biosensor, based on TiO2 nanoparticles, for retroviral leucosis detection has been developed. The photoluminescence spectra were excited by solid state laser with wavelength 355 nm and measured in the range of 370-800 nm. Original photoluminescence spectrum of TiO2 nanoparticles showed wide maximum at 515 nm. The biosensitive layer was formed by immobilization of retroviral leucosis antigens on the surface of TiO2 nanoparticles. Immobilization of antigens on TiO2 surface led to UV-shift of photoluminescence spectrum and increase of PL intensity. The response to different concentrations of retroviral leucosis antibodies has been measured. The decrease o…
The fast photon detection system of COMPASS RICH-1
2007
Abstract A fast photon detection system has been built for the upgrade of COMPASS RICH-1, the large size gaseous RICH detector in use at the COMPASS Experiment at the CERN SPS since 2001. The photon detectors of the central region have been replaced by a new system based on multi-anode photomultipliers coupled to individual fused silica lens telescopes and a fast readout electronics system, while in the outer region the existing MWPCs with CsI photocathodes have been equipped with a new readout system, based on the APV chip. RICH-1 has been successfully operated in its upgraded version during the 2006 run. We report on the upgrade design and construction, and on the preliminary characteriza…
First results of the Instrumentation Line for the deep-sea ANTARES neutrino telescope
2006
In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system, as well as the calibration devices of the detector. The in-situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. T…
Search for multiwavelength emission from the binary millisecond pulsar PSR J1836-2354A in the globular cluster M22
2019
We present a multi-band search for X-ray, optical and $\gamma$-ray emission of the radio binary millisecond pulsar J1836-2354A, hosted in the globular cluster M22. X-ray emission is significantly detected in two Chandra observations, performed in 2005 and 2014, at a luminosity of $\sim$2-3$\times$10$^{30}$ erg s$^{-1}$, in the 0.5-8 keV energy range. The radio and the X-ray source positions are found consistent within 1$\sigma$ error box. No detection is found in archival XMM-Newton and Swift/XRT observations, compatible with the Chandra flux level. The low statistics prevents us to assess if the X-ray source varied between the two observations. The X-ray spectrum is consistent with a power…
Real-time and low-cost sensing technique based on photonic bandgap structures
2011
[EN] A technique for the development of low-cost and high-sensitivity photonic biosensing devices is proposed and experimentally demonstrated. In this technique, a photonic bandgap structure is used as transducer, but its readout is performed by simply using a broadband source, an optical filter, and a power meter, without the need of obtaining the transmission spectrum of the structure; thus, a really low-cost system and real-time results are achieved. Experimental results show that it is possible to detect very low refractive index variations, achieving a detection limit below 2 x 10(-6) refractive index units using this low-cost measuring technique. (C) 2011 Optical Society of America[
Quantum dots functionalised artificial peptides bioinspired to the D1 protein from the Photosystem II of Chlamydomonas reinhardtii for endocrine disr…
2021
Herein we describe the design and synthesis of novel artificial peptides mimicking the plastoquinone binding niche of the D1 protein from the green photosynthetic alga Chlamydomonas reinhardtii, also able to bind herbicides. In particular, molecular dynamics (MD) simulations were performed to model in silico the behaviour of three peptides, D1Pep70-H, D1Pep70-S264K and D1Pep70-S268C, as genetic variants with different affinity towards the photosynthetic herbicide atrazine. Then the photosynthetic peptides were functionalised with quantum dots for the development of a hybrid optosensor for the detection of atrazine, one of the most employed herbicides for weed control in agriculture as well …
Syntax Error Handling
1990
In the previous chapters we have seen that the various parsers discussed, at least whenever they are deterministic, detect an error in any nonsentence. This means, that on any nonsentence there is a computation ending with an error configuration. For practical parsers, mere error detection is not enough; the parser should also emit a meaningful error message and recover from the error. A recovery means that the error configuration is transformed into a non-error configuration at which normal parsing can be resumed. Moreover, the transformation should be done so that as few input symbols as possible will be discarded. The goal of the error recovery is to maximize the amount of input text tha…
The analog Resistive Plate Chamber detector of the ARGO-YBJ experiment
2015
The ARGO-YBJ experiment has been in stable data taking from November 2007 till February 2013 at the YangBaJing Cosmic Ray Observatory (4300 m a.s.l.). The detector consists of a single layer of Resistive Plate Chambers (RPCs) (6700 m2) operated in streamer mode. The signal pick-up is obtained by means of strips facing one side of the gas volume. The digital readout of the signals, while allows a high space–time resolution in the shower front reconstruction, limits the measurable energy to a few hundred TeV. In order to fully investigate the 1–10 PeV region, an analog readout has been implemented by instrumenting each RPC with two large size electrodes facing the other side of the gas volume…
PINGU: a vision for neutrino and particle physics at the South Pole
2017
The Precision IceCube Next Generation Upgrade (PINGU) is a proposed low-energy in-fill extension to the IceCube Neutrino Observatory. With detection technology modeled closely on the successful IceCube example, PINGU will provide a 6Mton effective mass for neutrino detection with an energy threshold of a few GeV. With an unprecedented sample of over 60,000 atmospheric neutrinos per year in this energy range, PINGU will make highly competitive measurements of neutrino oscillation parameters in an energy range over an order of magnitude higher than long-baseline neutrino beam experiments. PINGU will measure the mixing parameters $\theta_{\rm 23}$ and $\Delta m^2_{\rm 32}$, including the octan…