Isocratic and gradient elution in micellar liquid chromatography with Brij-35
2015
Polyoxyethylene(23)lauryl ether (known as Brij-35) is a nonionic surfactant, which has been considered as an alternative to the extensively used in micellar liquid chromatography anionic surfactant sodium lauryl (dodecyl) sulfate, for the analysis of drugs and other types of compounds. Brij-35 is the most suitable nonionic surfactant for micellar liquid chromatography, owing to its commercial availability, low cost, low toxicity, high cloud temperature, and low background absorbance. However, it has had minor use. In this work, we gather and discuss some results obtained in our laboratory with several β-blockers, sulfonamides, and flavonoids, concerning the use of Brij-35 as mobile phase mo…
Analytical potential of mid-infrared detection in capillary electrophoresis and liquid chromatography: a review.
2010
Literature published in the last decade concerning the use of mid-infrared spectrometry as a detection system in separation techniques employing a liquid mobile phase is reviewed. In addition to the continued use of isocratic liquid chromatographic (LC) techniques, advances in chemometric data evaluation techniques now allow the use of gradient techniques on a routine basis, thus significantly broadening the range of possible applications of LC-IR. The general trend towards miniaturized separation systems was also followed for mid-IR detection where two key developments are of special importance. Firstly, concerning on-line detection the advent of micro-fabricated flow-cells with inner volu…
Characterization of poly(4-vinylpyridine 1-oxide) by free-solution capillary electrophoresis and micellar electrokinetic chromatography
2008
The migration characteristics of poly(4-vinylpyridine 1-oxide) (PVP-NO) in phosphate buffers of acidic pH (20 mM H 3 PO 4 or NaH 2 PO 4 ) have been studied using both free-solution capillary electrophoresis (FSCE) and MEKC. To inhibit adsorption, 250 mM o-phosphoethanolamine (2-aminoethyl dihydrogen phosphate) was used. In FSCE, PVP-NO showed a narrow peak and a broader band, both having anionic behavior. These peak and band were attributed to the free and aggregated or micellized PVP-NO forms, respectively. According to surface tension measurements, the CMC of SDS in the BGE was 1.8 and 0.48 mM in the absence and in the presence of 1000 μpg/mL PVP-NO, respectively, and the association of t…
Development and validation of a procedure for estimating the hydrophobicity of structurally unrelated compounds by micellar liquid chromatography
1999
Reversed-phase liquid chromatography has been used most often to estimate values of log P, but despite years of study, there is no universally accepted method of performing these estimations. The main problem has to do with the fact that the hydrophobic parameter, log k w , depends on the hydrogen bond acceptor-donor character of the compounds. The use of micellar mobile phases to perform these estimations is evaluated here, and the influence of the nature of the surfactant (anionic, cationic, and nonionic) on the log k-log P relationships is studied. The use of a nonionic surfactant, such as Brij35, to prepare the mobile phases provided adequate results regardeless of the hydrogen bond acc…
Micellar Liquid Chromatography: Fundamentals
2015
The reversed phase liquid chromatography (RPLC) mode with surfactant above the critical micellar concentration (CMC) has been called micellar liquid chromatography (MLC). In pure micellar systems, the retention behavior is explained by considering three phases or environments: surfactant-modified stationary phase, bulk aqueous solvent, and micellar pseudo-phase. Surfactant adsorption on the porous RPLC packing affects chromatographic retention, owing to the change of diverse surface properties of the stationary phase. In pure micellar systems, the retention behavior is explained by considering three phases or environments: surfactant-modified stationary phase, bulk aqueous solvent, and mice…
Comparison of the performance of butanol and pentanol as modifiers in the micellar chromatographic determination of some phenethylamines
2000
Abstract A procedure was developed for the determination of several phenethylamines (amphetamine, arterenol, ephedrine, phenylephrine, phenylpropanolamine, mephentermine, methoxyphenamine, pseudoephedrine and tyramine), using micellar mobile phases of sodium dodecyl sulfate (SDS), a C18 column and UV detection. The drugs were eluted at short retention times with conventional acetonitrile–water or methanol–water mobile phases. In contrast, in the micellar system, they were strongly retained due to association with the surfactant adsorbed on the stationary phase, and needed the addition of butanol or pentanol to be eluted from the column. These modifiers allowed a simple way of controlling th…
Influence of temperature on the behaviour of small linear peptides in capillary electrochromatography
2000
The influence of temperature, T, on the retention times, peak widths, peak symmetry coefficients and theoretical plate numbers of two small linear peptides, [Met5]enkephalin and [Leu5]enkephalin, has been studied with capillary electrochromatography (CEC) capillary columns of 100 microm I.D. and 250 mm packed length with a total length of 335 mm, containing 3 microm Hypersil n-octadecyl bonded silica. With increasing column temperature from 15 to 60 degrees C, the electroosmotic flow (EOF) and the column efficiencies increased, whereas the retention coefficients (Kcec) of both peptides decreased. A linear relationship was found between the EOF value and the square root of the temperature ov…
Highly efficient separation of amines by electrokinetic chromatography using resorcarene-octacarboxylic acids as pseudo-stationary phases
1998
Abstract Resorcarene-octacarboxylic acids, macrocyclic molecules built up by four alkylidene-bridged resorcinol units, were synthesized and used as pseudostationary phases in electrokinetic chromatography (EKC). Resorcarenes provide a stable structure and good solubility in electrolytes even with organic modifiers. The high electrophoretic mobility of the resorcarene-octacarboxylic acids introduced here as pseudostationary phases is based on the eight partly deprotonated carboxylic groups. This offers a broad migration time window, which is the main parameter for the resolution of peaks. From three compounds with different alkyl chain lengths (C 1 , C 5 , C 11 ), the C 11 -resorcarene-octa-…
Influence of the addition of modifiers on solute-micelle interaction in hybrid micellar liquid chromatography
1998
In reversed-phase micellar liquid chromatography (MLC) organic modifiers are usually added to the mobile phase to modify the eluent strength and to increase the efficiency of the chromatographic peaks. The effect of the modifiers methanol, ethanol, 1-propanol, 1-butanol, 1-pentanol, acetonitrile and tetrahydrofuran on the critical micelle concentration (cmc) of the anionic surfactant sodium dodecylsulphate (SDS) has been studied to enable understanding of the interactions between solute, micelles and bulk liquid in such hybrid eluents. Methanol, acetonitrile and tetrahydrofuran increased thecmc, whereas the other alcohols reduced its value. For butanol and pentanol, which partition into the…
Quantitative structure-retention and retention-activity relationships of beta-blocking agents by micellar liquid chromatography.
2001
Abstract Sixteen β-blocking agents (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol and timolol) showing a large range of hydrophobicity (octanol–water partition coefficients, log P between −0.026 and 2.81) were subjected to micellar liquid chromatography with sodium dodecyl sulfate as micelle forming agent, and n-propanol as organic modifier. The correlation between log P and the retention factor extrapolated to a mobile phase free of micelles and organic modifier was investigated. The use of an interpolated retention factor or the retention factor for specific individual exp…