The anodic and cathodic dissolution of Al and Al–Cu–Mg alloy
2010
Abstract Atomic emission spectroelectrochemistry (AESEC) was used to monitor the release of Al from 99.99% aluminum (1199 alloy) and Al, Mg, and Cu from 2024 Al alloy in 30 g/l NaCl electrolyte as a function of pH. The cathodic dissolution of Al was demonstrated and attributed to an increase in the pH at the interface due to the water reduction reaction. The dissolution of Mg was also observed but was a more complex function of current probably depending on the interfacial pH and the Al dissolution rate. The detachment of copper-rich particles was observed as very rapid spectroscopic emission transients (peak width
Determination of mineral and trace element concentrations in pine needles by ICP-OES: evaluation of different sample pre-treatment methods
2008
In the present study, the determination of mineral and trace elements (Al, B, Ca, Cu, Fe, K, Mg, Mn, Na, P and Zn) from pine needles using three sample pre-treatment methods followed by inductively coupled plasma optical emission spectrometry, was examined. Sample pre-treatment methods tested were microwave digestion, ultrasound-assisted digestion and dry ashing. The new ultrasound-assisted digestion method was optimised by the analysis of the standard reference material (SRM) 1575a (pine needles) sample. The speed of dry ashing method was significantly increased by ultrasound dissolution after ashing. All the ICP-OES measurements were performed in robust plasma conditions which were tested…
Formation of HXeO in a xenon matrix: Indirect evidence of production, trapping, and mobility of XeO (1 1Σ+) in solid Xe
2004
IR spectroscopy, laser induced fluorescence (LIF), and thermoluminescence (TL) measurements have been combined to monitor trapping, thermal mobility, and reactions of oxygen atoms in solid xenon. HXeO and O(3) have been used as IR active species that probe the reactions of oxygen atoms. N(2)O and H(2)O have been used as precursors for oxygen atoms by photolysis at 193 nm. Upon annealing of matrices after photolysis, ozone forms at two different temperatures: at 18-24 K from close O ...O(2) pairs and at approximately 27 K due to global mobility of oxygen atoms. HXeO forms at approximately 30 K reliably at higher temperature than ozone. Both LIF and TL show activation of oxygen atoms around 3…
The importance of incorporating a waste detoxification step in analytical methodologies
2015
The introduction of a waste detoxification step in the analytical process was highlighted using, as example, the determination of copper in pesticide formulations using electrogravimetry, flame atomic absorption spectroscopy and inductively coupled plasma optical emission spectroscopy. This quantitative study showed the improvement of the previously mentioned analytical methods, from a green perspective, after addition of electrodeposition or neutralization steps to the analytical process. Based on this, the application of the eco-scale and the Green Certificate to the evaluation of these methodologies allows the method to be moved from the B and C classes to the A class.
"Sweet Chemistry": a Green Way for Obtaining Selenium Nanoparticles Active against Cancer Cells
2017
We present an environment friendly synthesis of selenium nanoparticles and the study of their cytotoxic activity against uterine sarcoma cancer and fibroblasts cells. Amorphous selenium (a-SeNPs) and trigonal selenium (t-SeNPs) were synthesized using D-fructose as the reducing agent and characterized by high-resolution transmission electron microscopy (HRTEM), energy-dispersive X-ray spectroscopy (EDX), powder X-ray diffraction analysis (XRD), inductively coupled plasma optical emission spectrometry (ICP OES), dynamic light scattering (DLS) to obtain zeta potential values and cyclic voltammetry (CV). Particularly, a-SeNPs presented high toxicity toward the resistant cancer cell line MES-SA/…
Determination of chromium in foods by flame atomic absorption and inductively coupled plasma spectrometry
1989
Example of a technique for evaluation of interferences caused by complicated sample matrix elements in ICP-AES determination
2001
An example of a useful and rapid procedure for the evaluation of interferences caused by complicated sample matrices in inductively coupled plasma atomic emission spectrometry (ICP-AES) is described. Using simple acid-base standards, all the elements investigated were determined separately in complicated matrices with satisfactory results. Multiple linear regression was used to calculate the linear correction coefficients for each matrix element analyzed. Good analytical results improved still further when this correction method was used.
Simultaneous determination of hydride and non-hydride forming elements by inductively coupled plasma optical emission spectrometry
2011
e percentagens de recuperacao entre 97 e 103%. A aplicabilidade do sistema foi demonstrada na determinacao simultânea de Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Zn, As, Bi, Sb, Se e Te em amostras certificadas para elementos tracos, NIST 1549 (leite em po desnatado), NIST 1570a (folhas de espinafre), DORM-2 (musculo de cacao) e TORT-2 (hepatopâncreas de lagosta). Os resultados obtidos foram concordantes com os teores certificados. The operating characteristics of a dual nebulization system were studied including instrumental and chemical conditions for the hydride generation and analytical figures of merit for both, hydride and non hydride forming elements. Analytical performance of the neb…
Development and Optimization of Pre-Concentration Procedure of Rare-Earth Elements (REEs) in Their Minerals, Using Microwave - Assisted Sample Dissol…
2015
Abstract The aim of this research was to develop and optimize a procedure for determination of REEs in xenotime and monazite samples collected from Bangka Island, which were compared to Standard Monazite (71 AG) of Bureau of Analyzed Samples, London. ICP-OES method was used for the determination. The samples were dried and sterilized by heating for a week at 110 °C, before digesting with nitric acid and hydrofluoric acid, using a microwave-assisted digestion system. After a careful line selection, at the detection limits for all REEs in the ng/mL the REEs were reliably obtained at the 0.09 – 38% level.
Infrared evolved gas analysis during thermal investigation of lanthanum, europium and samarium carbonates
2003
Abstract The characterisation of rare earth elements carbonates (REECs) was performed by thermal analysis (TG–DTG) combined with simultaneous infrared evolved gas analysis–Fourier transform infrared (EGA–FTIR) spectroscopy. The TG–DTG curves were obtained using the Perkin-Elmer PC series TGA-7 thermogravimetric analyser in the temperature range 25–800 °C both in dynamic air and nitrogen atmosphere. La 2 (CO 3 ) 3 · n H 2 O, Eu 2 (CO 3 ) 3 · n H 2 O and Sm 2 (CO 3 ) 3 · n H 2 O were analysed, the dehydration and decarbonation steps were investigated and the water content was calculated. The trace rare earth elements in lanthanum, europium and samarium carbonates were determined by Philips PU…