Search results for " Error."

showing 10 items of 1034 documents

Characteristics and pathologies of the vitreo‐macular interface—results from the Gutenberg Health Study

2019

Purpose We aimed to determine the prevalence of characteristics and pathologies of the vitreo-macular interface within the general population. Methods The Gutenberg Health Study is a population-based study in Germany, including an ophthalmological examination with refraction, biometry and optical coherence tomography (OCT) imaging. Characteristics of the vitreo-macular interface were graded on volume scans including visibility of an epiretinal membrane, full-thickness macular hole, lamellar hole and pseudohole. Overall and age-specific prevalences including 95% confidence intervals [95%-CI] were calculated. Association analyses were conducted to determine systemic and ocular factors that ar…

MaleRefractive errorIntraocular pressuremedicine.medical_specialtygenetic structuresmedicine.medical_treatmentPopulationVitreous Detachment03 medical and health scienceschemistry.chemical_compound0302 clinical medicineGermanyOphthalmologyMyopiaPrevalencemedicineHumansMacula LuteaProspective StudieseducationMacular holeAgededucation.field_of_studybusiness.industryAge FactorsEpiretinal MembraneRetinalGeneral MedicineMiddle AgedCataract surgerymedicine.diseaseeye diseasesConfidence intervalVitreous BodyOphthalmologyCross-Sectional Studieschemistry030221 ophthalmology & optometryFemalesense organsEpiretinal membranebusinessTomography Optical Coherence030217 neurology & neurosurgeryActa Ophthalmologica
researchProduct

Genetic variants associated with human eye size are distinct from those conferring susceptibility to myopia

2021

Purpose: Emmetropization requires coordinated scaling of the major ocular components, corneal curvature and axial length. This coordination is achieved in part through a shared set of genetic variants that regulate eye size. Poorly coordinated scaling of corneal curvature and axial length results in refractive error. We tested the hypothesis that genetic variants regulating eye size in emmetropic eyes are distinct from those conferring susceptibility to refractive error.Methods: A genome-wide association study (GWAS) for corneal curvature in 22,180 adult emmetropic individuals was performed as a proxy for a GWAS for eye size. A polygenic score created using lead GWAS variants was tested for…

MaleRefractive errorLinkage disequilibriumgenetic structuresLOCIEmmetropiaGenome-wide association studyPRSS56AXIAL LENGTHLinkage Disequilibrium0302 clinical medicineCORNEAL CURVATURECorneaMyopiarefractive errorChild0303 health sciencesHERITABILITYMiddle Agedgenetic correlationAxial Length Eyemedicine.anatomical_structureeye sizeGROWTHFemaleAdultmedicine.medical_specialtyUK BiobankAdolescentBiologyRefraction OcularGenetic correlationPolymorphism Single NucleotideOCULAR COMPONENT DIMENSIONS03 medical and health sciencesYoung AdultOphthalmologymedicineGeneticsHumansGenetic Predisposition to Disease3125 Otorhinolaryngology ophthalmologyGENOME-WIDE ASSOCIATIONMETAANALYSIS030304 developmental biologyAgedmedicine.diseaseeye diseasesGenetic marker030221 ophthalmology & optometryHuman eyesense organsGenome-Wide Association StudyInvestigative Ophthalmology & Visual Science
researchProduct

Relative Peripheral Myopia Induced by Fractal Contact Lenses

2018

[EN] Purpose: To assess the peripheral refraction induced by Fractal Contact Lenses (FCLs) in myopic eyes by means of a two-dimensional Relative Peripheral Refractive Error (RPRE) map. Materials and Methods: This study involved 26 myopic subjects ranging from -0.50 D to -7.00 D. FCLs prototypes were custom-manufactured and characterized. Corneal topographies were taken in order to assess correlations between corneal asphericity and lens decentration. Two-dimensional RPREs were measured with an open-field autorefractor at 67 points, covering the central 60 x 30 degrees of the visual field. The bidimensional RPRE vector components: M, J(0) and J(45) of the difference between the values obtain…

MaleRefractive errorMaterials sciencegenetic structuresContact LensesRefraction OcularMyopia progressionlaw.inventionCorneaYoung Adult03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineFractalOpticslawMyopiamedicineHumansContact lensesbusiness.industryCorneal TopographyTwo-dimensional mapsmedicine.diseaseRefractioneye diseasesSensory SystemsSagittal planePeripheralVisual fieldLens (optics)OphthalmologyFractalsmedicine.anatomical_structureAutorefractorFISICA APLICADADisease Progression030221 ophthalmology & optometryFemalesense organsVisual FieldsFractalMATEMATICA APLICADAbusiness030217 neurology & neurosurgeryPeripheral refractive errorCurrent Eye Research
researchProduct

Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses

2013

Purpose To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). Design Two-center, randomized, prospective, double-masked study. Participants Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL. Intervention Phacoemulsification. Main Outc…

MaleRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentMesopic VisionVisual AcuitySettore MED/42 - Igiene Generale E ApplicataLens Implantation IntraocularSickness Impact ProfileSurveys and QuestionnairesMedicineContrast (vision)Prospective StudiesProspective cohort studyOPTICAL-QUALITYmedia_commonLenses IntraocularVision BinocularOUTCOMESMiddle AgedRESTORFemalemedicine.symptomA+3.00 DPhotopic visionDIOPTER ADDITIONmedicine.medical_specialtyINSTITUTE-REFRACTIVE ERRORmedia_common.quotation_subjectMODELSProsthesis DesignCataractDouble-Blind MethodOphthalmologyCONTRAST SENSITIVITYHumansBILATERAL IMPLANTATIONPhacoemulsificationColor Visionbusiness.industrySettore MED/30 - Malattie Apparato VisivoPhacoemulsificationMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyVISIONINSTITUTE-REFRACTIVE ERROR; CONTRAST SENSITIVITY; BILATERAL IMPLANTATION; DIOPTER ADDITION; OPTICAL-QUALITY; A+3.00 D; VISION; RESTOR; OUTCOMES; MODELSReadingQuality of LifeOptometryMultifocal IOL diffractive Quality of lifebusinessFollow-Up Studies
researchProduct

Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens

2009

Our purpose was to assess the visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL; Carl Zeiss Meditec, Jena, Germany) in patients with hyperopia. We did a prospective and nonrandomized study. One hundred and seventy eyes of 85 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low to moderate hyperopia (IOL power, 21 to 24.5 diopters [D]) and high hyperopia (IOL power, 25 to 36 D). Monocular and binocular best spectacle-corrected visual acuity (BSCVA), best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (VA), and distance contrast sensitivity …

MaleRefractive errormedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensContrast SensitivityVision disorderTonometry OcularLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesIntraocular PressureDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryHipermetropíaPresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOftalmologíaOptometryFemalesense organsmedicine.symptombusinessPhotopic visionAmerican Journal of Ophthalmology
researchProduct

Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.

2007

To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…

MaleRefractive errormedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaEye diseasemedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensResidualVision disorderPostoperative ComplicationsApodizationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansProspective StudiesAgedLenses IntraocularMonocularbusiness.industryMiddle Agedmedicine.diseaseRefractive Errorseye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Foldable toric intraocular lens for astigmatism correction in cataract patients.

2007

PURPOSE: To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING: Ophthalmology Service, Donostia Hospital, San Sebastian, Spain. METHODS: This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. RESU…

MaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensAstigmatismRefraction OcularVision disorderLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismPhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Reliability of a new analysis to compute time to stabilization following a single leg drop jump landing in children.

2019

Although a number of different methods have been proposed to assess the time to stabilization (TTS), none is reliable in every axis and no tests of this type have been carried out on children. The purpose of this study was thus to develop a new computational method to obtain TTS using a time-scale (frequency) approach [i.e. continuous wavelet transformation (WAV)] in children. Thirty normally-developed children (mean age 10.16 years, SD = 1.52) participated in the study. Every participant performed 30 single-leg drop jump landings with the dominant lower limb (barefoot) on a force plate from three different heights (15cm, 20cm and 25cm). Five signals were used to compute the TTS: i) Raw, ii…

MaleResearch ValidityMuscle PhysiologyTime FactorsPhysiologyIntraclass correlationPolynomialsSignalRoot mean square0302 clinical medicineContinuous waveletStatisticsMedicine and Health SciencesBiomechanicsChildMusculoskeletal SystemReliability (statistics)MathematicsSignal processingMultidisciplinaryQRResearch AssessmentBiomechanical PhenomenaSignal FilteringPhysiological ParametersPhysical SciencesEngineering and TechnologyLegsMedicineFemaleAnatomyResearch ArticleMovementScienceResearch and Analysis Methods03 medical and health sciencesHumansMechanical PhenomenaLegBody WeightBiology and Life SciencesReproducibility of Results030229 sport sciencesAlgebraTransformation (function)Standard errorBody LimbsSignal ProcessingMusculoskeletal MechanicsMathematics030217 neurology & neurosurgeryPLoS ONE
researchProduct

Disability-related-distress in primary school learners with vision impairment due to uncorrected refractive error in KwaZulu-Natal Province, South Af…

2020

Background Uncorrected refractive error (URE) is a major cause of vision impairment among children that impacts negatively on their lives including distresses. We aim to understand the disability-related distress among vision-impaired children due to URE in rural and semi-rural South Africa using qualitative techniques. Methods Structured focus groups of children (aged 5-12 years old) with normal vision and vision impairment due to URE from four schools in Pinetown, KwaZulu Natal, South Africa, were performed (four mixed-gender group discussions and eight single gender group discussions). We recruited the study participants after the children underwent standardised vision screening. Criteri…

MaleRural PopulationRefractive errorCross-sectional studyVisionSocial SciencesPsychological DistressFamiliesSouth Africa0302 clinical medicineSociologyMedicine and Health SciencesPsychologyPublic and Occupational Health030212 general & internal medicineChildChildrenmedia_commonVisual ImpairmentsMultidisciplinarySchoolsQHumiliationRRefractive ErrorsSports ScienceDistressProfessionsSelf-confidenceChild PreschoolMedicineSensory PerceptionFemaleAnatomyPsychologyKwazulu natalClinical psychologyResearch ArticleSportsmedia_common.quotation_subjectScienceDisabilitiesVision DisordersEducation03 medical and health sciencesOcular SystemmedicineHumansDisabled PersonsStudentsBehaviorBiology and Life SciencesTeachersmedicine.diseaseFocus groupOphthalmologyCross-Sectional StudiesAge GroupsPeople and Places030221 ophthalmology & optometryEyesRecreationPopulation GroupingsHeadStress PsychologicalQualitative researchNeurosciencePLoS ONE
researchProduct

Exome sequencing in suspected monogenic dyslipidemias.

2015

Background— Exome sequencing is a promising tool for gene mapping in Mendelian disorders. We used this technique in an attempt to identify novel genes underlying monogenic dyslipidemias. Methods and Results— We performed exome sequencing on 213 selected family members from 41 kindreds with suspected Mendelian inheritance of extreme levels of low-density lipoprotein cholesterol (after candidate gene sequencing excluded known genetic causes for high low-density lipoprotein cholesterol families) or high-density lipoprotein cholesterol. We used standard analytic approaches to identify candidate variants and also assigned a polygenic score to each individual to account for their burden of commo…

MaleSettore MED/09 - Medicina InternaMedical BiotechnologyDNA sequencing; exome; exome sequencing; genetics human; lipids; mendelian geneticsBiologyCardiorespiratory Medicine and HaematologyNovel genelipidsmendelian geneticsGene mappingClinical ResearchGenetics2.1 Biological and endogenous factorsHumansgeneticsExomeDNA sequencinghumanAetiologyMendelian disordersExomeGenetics (clinical)Exome sequencingDyslipidemiasGeneticsInborn ErrorsHuman GenomeHigh-Throughput Nucleotide SequencingAtherosclerosisMetabolismCardiovascular System & Hematologylipids (amino acids peptides and proteins)DNA sequencing; exome; genetics; human; lipidsFemalegeneticCardiology and Cardiovascular Medicineexome sequencingexomeMetabolism Inborn ErrorsCirculation. Cardiovascular genetics
researchProduct