Search results for " Infrared Spectroscopy"
showing 10 items of 438 documents
Characterization of particle morphology of biochanin A molecularly imprinted polymers and their properties as a potential sorbent for solid-phase ext…
2014
Abstract Molecularly imprinted polymers (MIPs) with biochanin A as a template were obtained using a bulk polymerization with non-covalent imprinting approach. The polymers were prepared in acetonitrile as porogen, using ethylene glycol dimethacrylate (EDMA) as cross-linking agent. The synthesis, with an application of 1′,1′-azobis(cyclohexanecarbonitrile) (ACHN) as an initiator, has been performed thermally. During the synthesis process the effect of different functional monomers such as methacrylic acid (MAA), acrylamide (AA) and 4-vinylpyridine (4-VP) was investigated. The application of nitrogen sorption porosimetry, scanning electron microscopy (SEM), and Fourier transform infrared spec…
Decoding vibrational states of Concanavalin A amyloid fibrils.
2015
International audience; Amyloid and amyloid-like fibrils are a general class of protein aggregates and represent a central topic in life sciences for their involvement in several neurodegenerative disorders and their unique mechanical and supramolecular morphological properties. Both their biological role and their physical properties, including their high mechanical stability and thermodynamic inertia, are related to the structural arrangement of proteins in the aggregates at molecular level. Significant variations may exist in the supramolecular organization of the commonly termed cross-β structure that constitutes the amyloid core. In this context, a fine knowledge of the structural deta…
Quantification of minerals from ATR-FTIR spectra with spectral interferences using the MRC method.
2017
A method for quantifying the individual components of mineral samples based on attenuated total reflectance - Fourier transform infrared spectroscopy (ATR-FTIR) is described, extending the constant ratio (CR) method to analytes absorbing in a common range of wavenumbers. Absorbance values in the spectral region where the analytes absorb relative to the absorbance of an internal standard absorbing at a wavenumber where the analytes do not absorb, permits the quantification of N analytes using measurements at N fixed wavenumbers. The method was tested for mixtures of albite, orthoclase, kaolin and quartz.
Nutritional parameters of commercially available milk samples by FTIR and chemometric techniques
2004
Abstract A chemometric study on the prediction of the main nutritional aspects of milk has been carried out by using fourier transform infrared spectroscopy (FTIR) attenuated total reflectance (ATR) measurements of commercially available milk samples of different types. Whole, semi and skimmed milks, enriched or not with calcium, vitamins or modified by alteration of lipid or sugar composition were considered. After evaluating different strategies for data acquisition and ATR cleaning between samples, hierarchical cluster analysis (HCA) was carried out for classification of samples in order to choose the calibration set. The prediction capabilities of partial least squares (PLS) data treatm…
FT-IR quantitative analysis of solvent mixtures by the constant ratio method
1999
Abstract An analytical methodology to quantify compounds in complex mixtures by FTIR spectroscopy is proposed and the “Constant Ratio Method” (CRM) was developed. The addition of a standard to the sample allows us to establish a constant KMS characteristic of the Analyte/Standard system which can be employed as a quantification factor of the analyte in different samples . In the proposed method the measurements are independent of optical path length. This method has been successfully applied to quantify butylacetate and toluene in binary and tertiary samples and tertiary mixtures. Butylacetate/toluene/nujol have been resolved employing valeronitrile as standard, obtaining values for relativ…
Procedure for automated background correction in flow systems with infrared spectroscopic detection and changing liquid-phase composition
2009
This paper describes a partial least squares (PLS) based automatic procedure to correct for changes in the spectral contribution of the solvent or solvent mixtures from solute spectra recorded in these solvents. The procedure was developed for successful on-line Fourier transform infrared (FT-IR) detection in gradient high-performance liquid chromatography (HPLC) separations. It requires a reference FT-IR data set containing all possible combinations of the expected variation in solvent composition. Furthermore, a spectral region ( A) in these spectra is required where the solvents show absorption but the analytes do not. This is the case for the system ACN:H2O, an often-applied solvent mi…
Identification and determination of synthetic cannabinoids in herbal products by dry film attenuated total reflectance-infrared spectroscopy.
2017
A new procedure has been developed for the identification and quantitative determination of synthetic cannabinoids in illicit herbal preparations. The methodology is based on the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) measurement of sample extracts with 2-propanol drying 5µL of the extracts onto the ATR crystal. The qualitative identification was carried out on the 2-propanol extract after identification of the herbal matrix, followed by its subtraction and using a cut-off criterion of 75%. Quantitative determination was made by univariate calibration using the absorbance of the band located at 1520cm-1 of the spectrum. Four different cannabin…
New insights in the formation of silanol defects in silicalite-1 by water intrusion under high pressure.
2010
International audience; The "water-silicalite-1" system is known to act as a molecular spring. The successive intrusion-extrusion cycles of liquid water in small crystallites (6 × 3 × 0.5 μm(3)) of hydrophobic silicalite-1 were studied by volumetric and calorimetric techniques. The experiments displayed a decrease of the intrusion pressure between the first intrusion-extrusion cycle and the consecutive ones, whereas the extrusion pressures remained unchanged. However, neither XRD studies nor SEM observations revealed any structural and morphological modifications of silicalite-1 at the long-range order. Such a shift in the value of the intrusion pressure after the first water intrusion-extr…
Attenuated Total Reflection-Fourier transform infrared analysis of the fermentation process of pineapple
2005
Abstract A direct and reagent free procedure has been developed to monitor the fermentation process of pine apple nectar using Attenuated Total Reflectance Fourier-transform mid-infrared spectrometry (FT-IR) and multivariate analysis. A classical 4 2 design for standards was employed for calibration using the information in the spectral range from 907 to 1531 cm −1 of the first order derivative spectra after mean centering of infrared data. The root mean square error of calibration (RMSEC) of 0.040, 0.021, 0.063 and 0.074% w/w were obtained for glucose, fructose, saccharose and ethanol, respectively, and a mean relative validation error of 2.9, 2.1, 2.6 and 3.6% was achieved for glucose, fr…
Cubic smoothing splines background correction in on-line liquid chromatography–Fourier transform infrared spectrometry
2010
A background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry (LC-FTIR) is proposed. The developed approach applies univariate background correction to each variable (i.e. each wave number) individually. Spectra measured in the region before and after each peak cluster are used as knots to model the variation of the eluent absorption intensity with time using cubic smoothing splines (CSS) functions. The new approach has been successfully tested on simulated as well as on real data sets obtained from injections of standard mixtures of polyethylene glycols with four different molecular weights in methanol:water, 2-propano…