Search results for " Laboratory"

showing 10 items of 622 documents

Assessment of the antioxidant and antibacterial activities of different olive processing wastewaters.

2017

Olive processing wastewaters (OPW), namely olive mill wastewater (OMW) and table-olive wastewaters (TOW) were evaluated for their antibacterial activity against five Gram-positive and two Gram-negative bacteria using the standard disc diffusion and thin layer chromatography (TLC)-bioautography assays. Disc diffusion screening and bioautography of OMW were compared to the phenolic extracts of table-olive brines. Positive activity against S. aureus was demonstrated. The optimization of chromatographic separation revealed that hexane/acetone in the ratio of 4:6 was the most effective for phenolic compounds separation. A HPLC-MS analysis was performed showing that only two compounds, hydroxytyr…

Thin-Layer Chromatography0301 basic medicineDPPHStaphylococcuslcsh:MedicineWastewaterPathology and Laboratory MedicineBiochemistryAntioxidantsMass Spectrometrychemistry.chemical_compoundPlant ProductsMedicine and Health SciencesStaphylococcus Aureuslcsh:ScienceChromatography High Pressure LiquidMultidisciplinaryBioautographyAntimicrobialsChromatographic TechniquesOlivesDrugsAgriculture04 agricultural and veterinary sciencesPlants040401 food scienceThin-layer chromatographyBacterial PathogensAnti-Bacterial AgentsHexaneChemistryBioassays and Physiological AnalysisMedical MicrobiologyPhysical SciencesPathogensAntibacterial activityResearch ArticleMicrobial Sensitivity TestsResearch and Analysis MethodsMicrobiologyVegetable OilsFruitsInhibitory Concentration 5003 medical and health sciences0404 agricultural biotechnologyPhenolsPicratesMicrobial ControlOleaAcetonePhenolsMicrobial PathogensPharmacologyChromatographyBacteriaBiphenyl Compoundslcsh:RChemical CompoundsOrganismsBiology and Life SciencesAgronomyTyrosolPlanar Chromatography030104 developmental biologychemistryAntibacterialsHydroxytyrosollcsh:QChromatography Thin LayerBiochemical AnalysisCrop SciencePLoS ONE
researchProduct

Oxygen uptake kinetics and energy system's contribution around maximal lactate steady state swimming intensity

2017

Made available in DSpace on 2018-11-26T17:20:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2017-02-28 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) Ministry of Education of Brazil The purpose of this study was to examine the oxygen uptake ((V) over dotO(2)) kinetics and the energy systems' contribution at 97.5, 100 and 102.5% of the maximal lactate steady state (MLSS) swimming intensity. Ten elite female swimmers performed three-to-five 30 min submaximal constant swimming bouts at imposed paces for the determination of the swimming velocity (v) at 100% MLSS based on a 7 x 200 m intermittent incremental protocol until voluntary exhaustion to find the v associated…

Time FactorsAnaerobic ThresholdPhysiologyVelocitylcsh:MedicinePathology and Laboratory MedicineOxygenBiochemistryOxygen uptake kinetics0302 clinical medicineMedicine and Health SciencesPublic and Occupational Healthlcsh:ScienceFatigueMultidisciplinaryChemistryPhysicsTime constantClassical Mechanics16. Peace & justiceSports ScienceBody FluidsChemistryvVO2maxBloodPhysical SciencesLactatesFemaleAnatomyAnaerobic exerciseResearch ArticleChemical ElementsSportsAdolescentchemistry.chemical_elementBioenergetics03 medical and health sciencesYoung AdultMotionAnimal scienceOxygen ConsumptionSigns and SymptomsDiagnostic MedicineHumansLactic AcidSports and Exercise MedicineEnergy systemExerciseSwimmingBehaviorBiological Locomotionlcsh:RBiology and Life Sciences030229 sport sciencesPhysical ActivityIntensity (physics)OxygenKineticsAthletesPhysical FitnessExercise TestPhysical EnduranceRecreationlcsh:QSteady state (chemistry)Energy Metabolism030217 neurology & neurosurgery
researchProduct

Micellar liquid chromatography in doping control.

2010

The issue of doping control in sport involves the development of reliable analytical procedures and efficient strategies to process a large number of samples in a short period of time. Reversed-phase LC techniques with aqueous–organic mobile phases and MS or diode-array detection yield satisfactory results for the identification of prohibited substances in sport. However, time-consuming sample pretreatment steps are required, which reduces sample throughput. Micellar LC (MLC) that uses hybrid mobile phases of surfactant above its critical micellar concentration and organic solvent has been revealed as an interesting alternative. The surfactant sodium dodecyl sulfate solubilizes the protein…

Time FactorsClinical BiochemistryAnalytical chemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundSurface-Active AgentsPulmonary surfactantHumansGeneral Pharmacology Toxicology and PharmaceuticsSodium dodecyl sulfateDiureticsMicellesDoping in SportsChromatographyChemistryProteinsReproducibility of ResultsSodium Dodecyl SulfateWaterGeneral MedicineDilutionMedical Laboratory TechnologySolubilityMicellar liquid chromatographyCritical micelle concentrationYield (chemistry)SolventsAnalytical proceduresSelectivityChromatography LiquidBioanalysis
researchProduct

Blood Component Therapy and Coagulopathy in Trauma: A Systematic Review of the Literature from the Trauma Update Group

2016

Background Traumatic coagulopathy is thought to increase mortality and its treatment to reduce preventable deaths. However, there is still uncertainty in this field, and available literature results may have been overestimated. Methods We searched the MEDLINE database using the PubMed platform. We formulated four queries investigating the prognostic weight of traumatic coagulopathy defined according to conventional laboratory testing, and the effectiveness in reducing mortality of three different treatments aimed at contrasting coagulopathy (high fresh frozen plasma/packed red blood cells ratios, fibrinogen, and tranexamic acid administration). Randomized controlled trials were selected alo…

Tranexamic acidPhysiologyGlycobiologylcsh:MedicineCardiovascular MedicinePathology and Laboratory MedicineBiochemistryVascular Medicinelaw.inventionDatabase and Informatics MethodsFresh frozen plasma0302 clinical medicineRandomized controlled trialCoagulopathyAnimal CellslawAntifibrinolytic agentFibrinogen; Fresh frozen plasma; Tranexamic acid; Antifibrinolytic agent.Medicine and Health Sciences030212 general & internal medicineDatabase Searchinglcsh:ScienceMultidisciplinaryPlasma ExchangeHematologyBlood Coagulation DisordersClinical Laboratory SciencesAntifibrinolytic AgentsBody FluidsBloodtraumaTranexamic AcidCardiovascular DiseasesResearch DesignMeta-analysisObservational StudiesFresh frozen plasmaAnatomyCellular TypesResearch ArticlePlateletsmedicine.medical_specialtyDeath RatesHemorrhageBlood Component TransfusionResearch and Analysis MethodsExternal validity03 medical and health sciencesSigns and SymptomsPopulation MetricsDiagnostic MedicinemedicineCoagulopathyHumansBlood TransfusionMortalityIntensive care medicineBlood CoagulationAntifibrinolytic Agents; Blood Coagulation Disorders; Humans; Mortality; Plasma Exchange; Tranexamic Acid; Wounds and Injuries; Blood Component Transfusion; Biochemistry Genetics and Molecular Biology (all); Agricultural and Biological Sciences (all)DemographyGlycoproteinsBlood CellsAntifibrinolytic agentPopulation BiologyCoagulation DisordersTransfusion Medicinebusiness.industrylcsh:RBleedingAntifibrinolytic agent.Biology and Life SciencesFibrinogen030208 emergency & critical care medicineCell Biologymedicine.diseaseSurgeryPeople and PlacesWounds and Injurieslcsh:QObservational studyPacked red blood cellsbusinessPLOS ONE
researchProduct

Laboratori virtual d'ensenyament-aprenentatge: solució numèrica de les equacions de conservació mitjançant volums finits aplicades a superfícies este…

2014

En este treball es presenta el disseny d’un Laboratori virtual d’ensenyament-aprenentatge per a la resolució d’un problema model de Transferència de la Calor en la matèria d’Enginyeria Tèrmica del II curs del Grau d’Enginyer de Tecnologies Industrials de la Universidad Rey Juan Carlos de Madrid. En l’àmbit de la Dinàmica de Fluids Computacional i per mitjà de l’ús del programari de simulació d’Ansys Fluent s’introduïx l’alumne al disseny, modelatge del sistema, resolució, anàlisi i validació del model. El resultat d’esta experiència d’aprenentatge és no sols la mera resolució del problema, inabordable amb mètodes didàctics tradicionals, sinó el desenvolupament de la combinació de destreses,…

Transferencia de calor Docencia Dinámica de Fluidos Computacional Ansys Laboratorio virtuallcsh:Llcsh:L7-991Heat Transfer Teaching Computational Fluid Dynamics Ansys Virtual Laboratorylcsh:Education (General)lcsh:Education@tic: Revista d'Innovació Educativa
researchProduct

Computer Structure Laboratory

2019

La asignatura "Estructura de Computadores" es una asignatura obligatoria de segundo curso del Grado en Ingeniería Multimedia y del Grado en Ingeniería Informática. Tiene asignada una dedicación de 6 ECTS, siendo de carácter obligatorio en los dos grados. El material desarrollado son un total de 8 sesiones de laboratorio de 2 horas y media cada una, donde se estudia: jerarquía de memoria, centrándose en la memoria cache (3 sesiones), entrada y salida (2 sesiones) y periféricos (3 sesiones). En las 5 primeras prácticas se utiliza un software (MipsIt) que simula una máquina MIPS. En las 3 últimas sesiones se utiliza una máquina virtual con Linux. Las prácticas parten de ejemplos ya preparados …

UNESCO::CIENCIAS TECNOLÓGICAS::Tecnología de los ordenadores ::Arquitectura de ordenadoresComputer structure laboratory Cache memory Input Output System Peripherals
researchProduct

Thermal Design of Refridgerated Hexapole 18 GHZ ECRIS HIISI

2014

A project is underway for constructing a new 18 GHz ECR ion source HIISI at University of Jyväskylä. An innovative plasma chamber structure with grooves at magnetic poles for larger chamber radius at poles. The hexapole will be refridgerated to sub-zero temperatures to boost the coercivity and the remanence of the permanent magnet material and to allow the use of high remanence, low intrinsic coersivity permanent magnet materials. The hexapole structure is insulated from high temperature solenoid coils and plasma chamber by vacuum. The thermal design of the structure has been made using a thermal diffusion code taking in account radiative, conductive and convective heat transfer processes. …

University of JyväskyläHIISIPhysics::Plasma Physicsaccelerator laboratoryheavy ion ion source injectorECRIS
researchProduct

HIISI, New 18 GHZ ECRIS for the JYFL Accelerator Laboratory

2014

At the end of 2013 the Academy of Finland granted an infrastructure funding for the JYFL Accelerator Laboratory in order to increase beam intensities for the international user community. The primary objective is to construct a new high performance ECR ion source, HIISI (Heavy Ion Ion Source Injector), for the K130 cyclotron. Using room temperature magnets the HIISI has been designed to produce about the same magnetic field configuration as the superconducting ECRIS SUSI at NSCL/MSU for 18 GHz operation. An innovative structure will be used to maximize the radial confinement and demagnetization safety margin of the permanent magnets. The sextupole magnet is separated and insulated from the …

University of JyväskyläHIISI[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]accelerator laboratory[PHYS.PHYS.PHYS-ACC-PH] Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]heavy ion ion source injector
researchProduct

Status of new 18 GHz ECRIS HIISI

2018

A new 18 GHz ECR ion source HIISI is under commissioning at the Accelerator Laboratory at the University of Jyväskylä (JYFL). The main purpose of HIISI is to produce high-energy beam cocktails, e.g. Xe44+, for radiation effects testing of electronics with the K130 cyclotron. The initial commissioning results in 18+14 GHz operation with oxygen, argon and xenon are reported. The beam currents are compared to those produced by reference ion sources (JYFL 14 GHz ECRIS, GTS and SuSI). At the moment (October 2017) 560 µA of O6+ and 310 µA of Ar13+, for example, have been reached with HIISI at 2.3 kW total power. peerReviewed

University of JyväskyläHIISIionitsäteilyfysiikkasyklotronittutkimuslaitteetaccelerator laboratoryheavy ion ion source injector
researchProduct

Status of new 18 GHz ECRIS HIISI

2018

A new 18 GHz ECR ion source HIISI is under commissioning at the Accelerator Laboratory at the University of Jyvaskyla (JYFL). The main purpose of HIISI is to produce high-energy beam cocktails, e.g. Xe44+, for radiation effects testing of electronics with the K130 cyclotron. The initial commissioning results in 18+14 GHz operation with oxygen, argon and xenon are reported. The beam currents are compared to those produced by reference ion sources (JYFL 14 GHz ECRIS, GTS and SuSI). At the moment (October 2017) 560 µA of O6+ and 310 µA of Ar13+, for example, have been reached with HIISI at 2.3 kW total power.A new 18 GHz ECR ion source HIISI is under commissioning at the Accelerator Laboratory…

University of JyväskyläMaterials scienceCyclotrontutkimuslaitteetchemistry.chemical_elementRadiation01 natural sciences7. Clean energy010305 fluids & plasmasIonlaw.inventionNuclear physicsXenonHIISIlaw0103 physical sciencesheavy ion ion source injector010302 applied physicsArgonta114syklotronitIon sourcechemistrysäteilyfysiikkaMoment (physics)ionsaccelerator laboratoryBeam (structure)
researchProduct