Search results for " Resonance"
showing 10 items of 5579 documents
Beyond the amygdala: Linguistic threat modulates peri-sylvian semantic access cortices
2015
In this study, healthy volunteers were scanned using functional magnetic resonance imaging (fMRI) to investigate the neural systems involved in processing the threatening content conveyed via visually presented “threat words.” The neural responses elicited by these words were compared to those elicited by matched neutral control words. The results demonstrate that linguistic threat, when presented in written form, can selectively engage areas of lateral temporal and inferior frontal cortex, distinct from the core language areas implicated in aphasia. Additionally, linguistic threat modulates neural activity in visceral/emotional systems (amygdala, parahippocampal gyrus and periaqueductal gr…
Corpus callosum function in verbal dichotic listening: inferences from a longitudinal follow-up of Relapsing-Remitting Multiple Sclerosis patients.
2009
This study conducted a follow-up of 13 early-onset slightly disabled Relapsing-Remitting Multiple Sclerosis (RRMS) patients within an year, evaluating both CC area measurements in a midsagittal Magnetic Resonance (MR) image, and Dichotic Listening (DL) testing with stop consonant vowel (C-V) syllables. Patients showed a significant progressive loss of posterior CC areas (isthmus and splenium) related to increasing EDSS scores and an enhancing right ear advantage (REA) over time. A significant correlation between posterior CC areas and DL scores emerged in both evaluations, being negative for the right and positive for the left ear. The pattern of correlations suggests that the CC can serve …
Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.
2006
Purpose To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibili…
Prediction of complexity and complications of laparoscopic liver surgery: The comparison of the Halls‐score to the IWATE‐score in 100 consecutive lap…
2020
BACKGROUND The development of laparoscopic liver surgery is slower than in other disciplines. Two different scoring systems have been proposed to estimate difficulty of laparoscopic liver resections (LLR) preoperatively. The aim of this analysis was to compare these two scores in an independent patient cohort regarding the predictability of morbidity. METHODS All LLRs performed between 01/2011 until 01/2019 were identified from our prospective institutional database. Patient characteristics as well as intra- and postoperative data were analyzed. Postoperative complications were graded according to Dindo-Clavien classification. Difficulty of LLR was classified using IWATE- and Halls-score. R…
Muscle kinematics during isometric contraction: Development of phase contrast and spin tag techniques to study healthy and atrophied muscles
2004
Purpose To develop and compare phase-contrast (PC) and spin-tag (ST) MR imaging techniques for accurate quantification of velocity and displacement distribution in the muscle tendon complex of the lower leg during isometric contractions under in vivo conditions, in healthy subjects and subjects with atrophy. Materials and Methods Techniques were developed to acquire PC and ST dynamic images, gated to the force exerted by a subject during isometric contraction. Algorithms were optimized for correction of phase shading errors. Flow velocity quantification was validated in phantoms and ex vivo rabbit muscles. Trajectories of pixels calculated from PC images were compared with those in ST image…
Analysis of LDL and HDL size and number by nuclear magnetic resonance in a healthy working population: The LipoLab Study
2020
Background and aim Atherosclerosis is the underlying process in cardiovascular disease (CVD), the first cause of death in developed countries. We aimed to identify people with no known CVD and normal values of LDL-C and HDL-C, but with alterations in the number and size of lipoprotein particles (as measured by nuclear magnetic resonance [NMR]) and to analyse their sociodemographic, clinical and biochemical characteristics. Methods Cross-sectional study in occupational risks prevention centre in Castellon (Spain) in 2017 and 2018, in consecutively recruited adults (18-65 years) with no known CVD. Sociodemographic, clinical and biochemical variables were collected. Lipid profiles were analyse…
Metabolite profiling of fecal water extracts from human colorectal cancer.
2009
Colorectal cancer is the second leading cause of cancer death in developed countries. There is a need for better preventive strategies to improve the outcome of this disease. The increasing availability of high-throughput methodologies opens up new possibilities for screening new markers. The application of NMR metabolic profiling to fecal water extracts has interesting potential as a diagnostic tool for detecting colorectal cancer. We obtained NMR metabolic profiles of fecal water extracts from patients with colorectal cancer and healthy individuals, to characterize possible differences between them and to identify potential diagnostic markers. Our results show that metabolic profiling of …
1H and 13C HR-MAS spectroscopy of intact biopsy samples ex vivo and in vivo 1H MRS study of human high grade gliomas.
2004
High-resolution magic angle spinning (HR-MAS) one- and two-dimensional 1H and 13C nuclear magnetic resonance (NMR) spectroscopy has been used to study intact glioblastoma (GBM) brain tumour tissue. The results were compared with in vitro chemical extract and in vivo spectra. The resolution of 1H one-dimensional, 1H TOCSY and 13C HSQC HR-MAS spectra is comparable to that obtained on perchloric extracts. 13C HSQC HR-MAS spectra have been particularly useful for the identification of 37 different metabolites in intact biopsy tumours, excluding water and DSS components. To our knowledge, this is the most detailed assignment of biochemical compounds obtained in intact human tissue, in particular…
Usefulness of quantitative peritumoural perfusion and proton spectroscopic magnetic resonance imaging evaluation in differentiating brain gliomas fro…
2016
Objectives The purpose of our study was to evaluate whether peritumoural perfusion weighted and proton spectroscopic magnetic resonance imaging can be used in differentiating between primary gliomas and solitary metastases. Methods Ten low-grade gliomas, eight high-grade gliomas and 10 metastases were prospectively evaluated with magnetic resonance imaging, dynamic susceptibility contrast enhanced perfusion imaging and single-voxel proton magnetic resonance spectroscopy before surgical resection or stereotactic biopsy. Maximal relative cerebral blood volume values were calculated drawing three regions of interest of 2 cm2 in the non-enhancing peritumoural areas. Maximal relative cerebral bl…
In-Vivo Estimation and Repeatability of Force-Length Relationship and Stiffness of the Human Achilles Tendon using Phase Contrast MRI
2008
Purpose To devise a method using velocity encoded phase contrast MRI and MR-compatible dynamometry, for in vivo estimation of elastic properties of the human Achilles tendon and to assess within-session and day-to-day repeatability of this technique. Materials and Methods Achilles tendon force and calcaneus-movement-adjusted displacement were measured during a submaximal isometric plantarflexion in 4 healthy subjects, four repeated trials each. The measured force-length (F-L) relationship was least-squares fitted to a cubic polynomial. Typical error was calculated for tendon displacement at multiple force levels, stiffness from the “linear region,” and transition point from the displacement…