Search results for " Ultraviolet"
showing 10 items of 337 documents
Generalised H-point standard addition method for the isolation of the analyte signal from the sample signal when coelution of unknown compounds occur…
1999
The generalised H-point standard addition method (GHPSAM) is proposed for isolating the analytical signal of an analyte from the signal of an unknown sample. Samples containing two and three coeluting compounds have been analysed. The accuracy of the predictions depends on the shape of the analyte and interferent spectra but not on the degree of chromatographic overlap. This methodology involves the location of linear intervals for the unknown interference spectrum from the spectrum of the sample. Once the linear interval has been found the selection of three wavelengths within the interval will allow the cancellation of the signal of the unknown interferent. The method has been applied to …
Determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine by capillary electrophoresis using ultraviolet absorba…
2002
Abstract Two capillary electrophoresis methods have been developed for the direct determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine. Analytes were detected using conventional UV detection as well as laser-induced fluorescence (LIF) detection with an HeCd-laser operating at a wavelength of 325 nm. The results of both detection techniques were compared. Indeed, the limit of quantification was eightfold lower using LIF detection (50 ng/ml) in comparison to UV detection (400 ng/ml). As no interference due to endogenous urine compounds was observed, direct urine analysis was feasible. Analysis was very simple and fast—one run could be performed within…
A solid colorimetric sensor for the analysis of amphetamine-like street samples.
2016
A solid sensor obtained by embedding 1,2-naphthoquinone-4-sulfonate (NQS) into polydimethylsiloxane/tetraethylortosilicate/silicon dioxide nanoparticles composite has been developed to identify and determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxymetamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA). The analytes are derivatized inside the composite for 10 min to create a colored product which can be then quantified by measuring the diffuse reflectance or the color intensity after processing the digitalized image. Satisfactory limits of detection (0.002–0.005 g mL−1) and relative standard deviations (<10%) have been achieved. The proposed kit has been successfu…
Identification of fish species by reversed-phase high-performance liquid chromatography with photodiode-array detection
1998
A method for the separation of sarcoplasmic fish proteins by RP-HPLC is described. The procedure revealed significant differences useful for reliable identification of fish species. Sixteen of the most common Finnish freshwater fish species were differentiated by species-specific HPLC chromatograms obtained using photodiode-array detection (PAD) at 200-350 nm. The analytical column was a Hi-Pore RP-304 reversed-phase column. The separation was performed by a linear gradient of acetonitrile and water with a small amount of trifluoracetic acid (TFA). Star-symbol plots were constructed from the chromatograms to visualize the data. Clearly different HPLC protein profiles for most fish species w…
Solid state anion–π interactions involving polyhalides
2013
The stabilization of polyhalides in the solid state with the support of electron-deficient pentafluorophenyl groups is described. Furthermore, a synthetic approach towards the sensitive tetraiodide dianion is described and ESI mass spectrometric evidence for its presence in solution is reported.
Synthesis, characterization and the first crystal structure of the Zn(II) complex of 4,6-O-ethylidine-N-(2-hydroxybenzylidene)-β-D-glucopyranosylamine
2001
4,6-O-Ethylidine-N-(2-hydroxybenzylidene)-β-D-glucopyranosylamine (H3L1) and N-(5-bromo-2-hydroxybenzylidene-4,6-O-ethylidine-β-D-glucopyranosylamine (H3L2) molecules possessing a–C-1–N=C(H)–moiety for metal-ion binding were synthesized by condensing the 4,6–O–ethylidene–β–D–glucopyranosylamine with salicylaldehyde or 5–bromosalicylaldehyde. Complexes of these ligands with Zn(II) were isolated and characterized using elemental analysis, FTIR, UV–Vis absorption, NMR spectroscopic and FAB mass spectrometric techniques. The structure of the Zn(II) complex derived from H3L1 was established for the first time by a single-crystal X-ray diffraction study. The anomeric nature of the saccharide moie…
Spectroelectrochemistry of cytochrome c and azurin immobilized in nanoporous antimony-doped tin oxide
2011
Stable immobilization of two redox proteins, cytochrome c and azurin, in a thin film of highly mesoporous antimony-doped tin oxide is demonstrated via UV-vis spectroscopic and electrochemical investigation.
Symbiosis between photoactive nanoparticles and their organic ligands.
2013
Photoactive spherical metal and semiconductor nanoparticles (NPs) are smart systems that exhibit unique properties, such as a high surface-to-volume ratio, a broad absorption spectrum and size-dependent properties. They are capped with a considerable number of ligands required to give rise to stable organic and aqueous NP colloidal solutions. In addition, the ligands can also be used to introduce functionality at the NP periphery. In this case, the NP could act as a 3D-scaffold, which would make a high local concentration of a functional moiety at the NP periphery possible, moreover, the photophysical properties of the NP could be tuned. The combined action of the organic capping and the in…
SphinX soft X-ray spectrophotometer: Science objectives, design and performance
2011
The goals and construction details of a new design Polish-led X-ray spectrophotometer are described. The instrument is aimed to observe emission from entire solar corona and is placed as a separate block within the Russian TESIS X- and EUV complex aboard the CORONAS-PHOTON solar orbiting observatory. SphinX uses silicon PIN diode detectors for high time resolution measurements of the solar spectra in the range 0.8–15 keV. Its spectral resolution allows for discerning more than hundred separate energy bands in this range. The instrument dynamic range extends two orders of magnitude below and above these representative for GOES. The relative and absolute accuracy of spectral measurements is e…
Deconvolution procedure of the UV-vis spectra. A powerful tool for the estimation of the binding of a model drug to specific solubilisation loci of b…
2015
UV-vis-spectra evolution of Nile Red loaded into Tween 20 micelles with pH and [Tween 20] have been analysed in a non-conventional manner by exploiting the deconvolution method. The number of buried sub-bands has been found to depend on both pH and bio-surfactant concentration, whose positions have been associated to Nile Red confined in aqueous solution and in the three micellar solubilisation sites. For the first time, by using an extended classical two-pseudo-phases-model, the robust treatment of the spectrophotometric data allows the estimation of Nile Red binding constant to the available loci. Hosting capability towards Nile Red is exalted by the pH enhancement. Comparison between bin…