Search results for " analytic"

showing 10 items of 1718 documents

Characterization of chromatographic peaks using the linearly modified Gaussian model. Comparison with the bi-Gaussian and the Foley and Dorsey approa…

2017

To characterize column performance in liquid chromatography, several parameters must be obtained from experimental data. These parameters can be computed through the numerical integration of the net signal to calculate the moments after subtraction of the baseline. This requires the establishment of the peak integration limits. The whole process introduces significant uncertainty. For this reason, several alternative procedures have been proposed to measure the area, mean time and variance, based on the assumption that the chromatographic peak can be described with a mathematical function. This allows the calculation of the peak position and variance making use of the values of the experime…

ChromatographyChemistryGaussianmedia_common.quotation_subject010401 analytical chemistryOrganic ChemistryGeneral MedicineVariance (accounting)010402 general chemistry01 natural sciencesBiochemistryMeasure (mathematics)Asymmetry0104 chemical sciencesAnalytical ChemistryNumerical integrationsymbols.namesakePosition (vector)Linear ModelssymbolsRange (statistics)Gaussian network modelChromatography Liquidmedia_commonJournal of Chromatography A
researchProduct

Fast authentication of tea tree oil through spectroscopy

2018

Two new procedures, based on infrared spectroscopy in the near infrared (NIR) and mid infrared (MIR), have been developed for the authentication of tea tree oil (TTO) commercial samples. Infrared measurements were made on untreated samples by transmission NIR and attenuated total reflectance (ATR) followed by partial least square discriminant analysis (PLS-DA). These methods offer a fast and low cost alternative to enantiomeric two-dimensional gas chromatography coupled to mass detection usually employed to discriminate between authentic and non-authentic samples. In these studies, a set of 267 samples, including authentic and non-authentic labelled tea tree oil samples, were used to build …

ChromatographyChemistryInfrared010401 analytical chemistryNear-infrared spectroscopyTea tree oilInfrared spectroscopy02 engineering and technology021001 nanoscience & nanotechnologyLinear discriminant analysis01 natural sciences0104 chemical sciencesAnalytical ChemistryAttenuated total reflectionmedicineGas chromatography0210 nano-technologySpectroscopymedicine.drugTalanta
researchProduct

Current methodologies for phytosterol analysis in foods

2021

Abstract Plant sterols (PS) (phytosterols and phytostanols) are bioactive compounds of all vegetable foods where can be found as free sterol alcohols and as conjugates. These latter forms have been less studied, although they may have potential beneficial effects, whereas some PS have several approved health claims, especially in lowering blood cholesterol levels. In this context, it is necessary to establish analytical methods for food authentication, assessing PS health benefits and unfolding future applications. Several extraction methodologies have been employed for the extraction of PS from food matrixes (usually solvent extraction and saponification) although solid-phase extraction, s…

ChromatographyChemistryPhytosterol010401 analytical chemistryExtraction (chemistry)Context (language use)02 engineering and technology021001 nanoscience & nanotechnologyTandem mass spectrometryMass spectrometry01 natural sciences0104 chemical sciencesAnalytical Chemistrychemistry.chemical_compoundGas chromatography0210 nano-technologyDerivatizationSpectroscopySaponificationMicrochemical Journal
researchProduct

Method development for the determination of 1,1-dimethylhydrazine by the high-performance liquid chromatography-mass spectrometry technique.

2018

Unsymmetrical dimethyl hydrazine is highly toxic, carcinogenic compound, widely used for organic synthesis and drug development. Therefore, due to its high reactivity, direct analysis is problematic. Current study proposes to use derivatization reaction to increase selectivity and sensitivity of high-performance liquid chromatography–mass spectrometry method. Different derivatization agents were tested and optimal reaction media was found. Derivatization was performed by using small amounts of reagents to lower the cost of analysis. The full validation of the method was performed and it can be used in a routine control in pharmaceutical analysis. Method sensitivity is 0.15 ppm, and lineari…

ChromatographyElectrospray ionization010401 analytical chemistryGeneral Medicine010402 general chemistryTandem mass spectrometryMass spectrometry01 natural sciencesHigh-performance liquid chromatographyAtomic and Molecular Physics and Optics0104 chemical scienceschemistry.chemical_compoundchemistryDimethylhydrazineReactivity (chemistry)Organic synthesisDerivatizationSpectroscopyEuropean journal of mass spectrometry (Chichester, England)
researchProduct

Analysis of tricyclic antidepressants in pharmaceuticals by microemulsion liquid chromatography

2021

Abstract Basic compounds yield long retention times and broad and asymmetric peaks in reversed-phase liquid chromatography, due to interaction with residual silanols in the columns. The addition of the surfactant sodium dodecyl sulphate in the so called micellar liquid chromatography enhances the efficiency, but long retention is achieved, due to electrostatic interaction between the cationic species of basic compounds and the anionic sulphate group of the surfactant. This forces the addition of a strong organic solvent to get appropriate times. An alternative is the use of a microemulsion (ME), formed by mixing surfactant, oil and an alcohol as co-surfactant. Association of hydrophobic com…

ChromatographyElutionChemistry010401 analytical chemistryCationic polymerizationAlcohol02 engineering and technology021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesAnalytical Chemistrychemistry.chemical_compoundPulmonary surfactantMicellar liquid chromatographyYield (chemistry)Microemulsion0210 nano-technologySpectroscopyOctaneMicrochemical Journal
researchProduct

Molecularly imprinted polymer-based device for field collection of oral fluid samples for cocaine identification.

2020

In this paper, a low-cost, rapid, easy, and potentially portable tool for the identification of cocaine and its semi-quantitative determination in oral fluid has been proposed. A field collection device has been designed, based on a cotton pad with an indicator and a molecularly imprinted polymer (MIP) sorbent, to selective retain cocaine from oral fluid components. After sample collection, cocaine is transferred by using phosphate buffer to the MIP and then eluted with 2-propanol. The obtained extract is analysed by ion mobility spectrometry (IMS), providing a cut-off value of 20 µg L-1 that identifies 100 % true-positive and 95 % true-negative samples. The MIP-IMS procedure has been valid…

ChromatographyElutionIon-mobility spectrometryChemistryPolymers010401 analytical chemistryOrganic ChemistryMolecularly imprinted polymerGeneral Medicine010402 general chemistry01 natural sciencesBiochemistry0104 chemical sciencesAnalytical ChemistryMolecular ImprintingSubstance Abuse DetectionHealth personnelIdentification (information)CocaineIon Mobility SpectrometryOral fluidHumansSample collectionSalivaLateral flow immunoassayJournal of chromatography. A
researchProduct

Evaluation of selected buffers for simultaneous determination of ionic and acidic pesticides including glyphosate using anion exchange chromatography…

2019

Ion chromatography coupled with mass spectrometry is an established technique for determination of ionic analytes, however, sophisticated buffer removal equipment is required to eliminate inorganic compounds from the eluate before introduction into the ion source of mass spectrometer. A standard high-performance liquid chromatography coupled with tandem mass spectrometry setup using an ion exchange column (Metrosep® A Supp 5) is proposed as an alternative approach. For that reason, some buffers including non-volatile carboxylic acid based solutions have been evaluated for simultaneous trace determination of ionic and acidic pesticides including glyphosate in the same extract without a need …

ChromatographyIon exchangeElution010401 analytical chemistryChlorateIon chromatographyFiltration and Separation010501 environmental sciencesBromateTandem mass spectrometryMass spectrometry01 natural sciencesIon source0104 chemical sciencesAnalytical Chemistrychemistry.chemical_compoundchemistry0105 earth and related environmental sciencesJournal of Separation Science
researchProduct

Miniature diamond-anvil cells for FTIR-microspectroscopy of small quantities of biosamples.

2018

Fourier transform infrared (FTIR) spectroscopy techniques and data analyses have become widely available, are easy to use, and are convenient for studies of various biosamples, especially in biomedical science. Yet, cultivation of cells and purification of cell components are costly, often methodically challenging, and time and labor consuming. Therefore, reduction of the sample amount is of high value. Here we propose a novel method for the analysis of small quantities of biosamples by FTIR-microscopy of dry films using a diamond-anvil cell (DAC). This approach allows us to decrease the sample volume at least a hundred times compared to that for a high-throughput screening device (HTS-XT, …

ChromatographyMaterials science010401 analytical chemistry02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesBiochemistryDiamond anvil cell0104 chemical sciencesAnalytical ChemistrySample volumeHomogeneousElectrochemistryEnvironmental ChemistryFourier transform infrared spectroscopy0210 nano-technologySpectroscopyBiochemical markersThe Analyst
researchProduct

Essential oil counterfeit identification through middle infrared spectroscopy

2018

Abstract Infrared spectroscopy (FTIR) has been employed for a fast quality control of commercial essential oils from different plant species. 47 samples were obtained from Algerian and Spanish market and directly measured, without any previous treatment, by attenuated total reflectance Fourier transform Infrared spectroscopy (ATR-FTIR), in the wavenumber region between 4000 and 550 cm−1. Pure essential oils were obtained by hydro- and steam-distillation extraction methods and their ATR spectra obtained. Results found evidenced the presence of solvents in some commercial formulations and permitted a rapid authentication of pure essential oils correctly extracted from those diluted. The propo…

ChromatographyMaterials science010405 organic chemistry010401 analytical chemistryInfrared spectroscopy01 natural sciencesEnvironmentally friendly0104 chemical sciencesAnalytical Chemistrylaw.inventionlawAttenuated total reflectionMiddle infraredPlant speciesFourier transform infrared spectroscopySpectroscopySpectroscopyEssential oilMicrochemical Journal
researchProduct

Column technology in liquid chromatography

2017

This chapter deals with the most important part of the liquid chromatography (LC) system: the column enabling the efficient and fast resolution of complex mixtures. It is divided into seven sections under the overall aspects of manufacture, operation, and evaluation of analytical columns for the user. The first three sections highlight the column design and hardware, followed by a thorough treatment of the properties of microparticulate silica adsorbents as packing material, stationary phases performed by surface functionalization, and the column filling process. Then, the implementation of the column into the LC system is discussed, leading into chromatographic column testing as a C18-bond…

ChromatographyMaterials sciencePeriod (periodic table)Resolution (mass spectrometry)010401 analytical chemistrySilica column02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesColumn (database)High-performance liquid chromatography0104 chemical sciencesHighly sensitiveAdsorptionSurface modification0210 nano-technologyPorosityColumn design
researchProduct