Search results for " and optics"
showing 10 items of 4468 documents
Noncontact monitoring of vascular lesion phototherapy efficiency by RGB multispectral imaging.
2013
A prototype low-cost RGB imaging system consisting of a commercial RGB CMOS sensor, RGB light-emitting diode ring light illuminator, and a set of polarizers was designed and tested for mapping the skin erythema index, in order to monitor skin recovery after phototherapy of vascular lesions, such as hemangiomas and telangiectasias. The contrast of erythema index (CEI) was proposed as a parameter for quantitative characterization of vascular lesions. Skin recovery was characterized as a decrease of the CEI value relative to the value before the treatment. This approach was clinically validated by examining 31 vascular lesions before and after phototherapy.
Effect of luminance on photopic visual acuity in the presence of laser speckle
1988
Visual acuity in coherent and incoherent light has been determined by using square-wave gratings of 100% contrast. Luminance was varied from 3 to 400 cd/m2. Coherent illumination resulted in a 40% loss of visual acuity. This is probably due to the masking effect of coherent spatial noise (speckle). However, the most interesting finding is the change in shape of the photopic visual-acuity-luminance function. With coherent illumination, the function is vertically displaced and of a different gradient. An increase in luminance produces a decrease in visual acuity. This indicates that the masking effect of the speckle is dependent on luminance. Two observers were used, and similar results were …
Relationship between foot eversion and thermographic foot skin temperature after running.
2017
The main instruments to assess foot eversion have some limitations (especially for field applications), and therefore it is necessary to explore new methods. The objective was to determine the relationship between foot eversion and skin temperature asymmetry of the foot sole (difference between medial and lateral side), using infrared thermography. Twenty-two runners performed a running test lasting 30 min. Skin temperature of the feet soles was measured by infrared thermography before and after running. Foot eversion during running was measured by kinematic analysis. Immediately after running, weak negative correlations were observed between thermal symmetry of the rearfoot and eversion at…
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness
2013
Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…
Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths
2016
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…
Photobleaching effects onin vivoskin autofluorescence lifetime
2015
The autofluorescence lifetime of healthy human skin was measured using excitation provided by a picosecond diode laser operating at a wavelength of 405 nm and with fluorescence emission collected at 475 and 560 nm. In addition, spectral and temporal responses of healthy human skin and intradermal nevus in the spectral range 460 to 610 nm were studied before and after photobleaching. A decrease in the autofluorescences lifetimes changes was observed after photobleaching of human skin. A three-exponential model was used to fit the signals, and under this model, the most significant photoinduced changes were observed for the slowest lifetime component in healthy skin at the spectral range 520 …
Evaluation of Nanostructured Coatings for the Protection of Apuan Marble Stone
2019
Nowadays the use of multifunctional nanomaterials has significantly increased with interesting applications for the cultural heritage conservation sector, leading to the definition and use of products with innovative properties. Therefore, a preliminary validation of the performances and behavior over time of these treatments becomes an unavoidable key point for a correct use of these products before being applied to historical materials, in order to avoid irreparable damage over time. In this direction, the aim of this study was to evaluate the effectiveness of the treatment with multifunctional nanostructured products on Apuan marble. The focus of the work was to test methods to accelerat…
Supramolecular Aggregates in Vacuum: Positively Mono-Charged Sodium Alkanesulfonate Clusters
2010
The formation and structural features of positively mono-charged aggregates of sodium bis(2-ethylhexyl) sulfosuccinate (AOT) and sodium methane—(MetS), butane—(ButS) and octane—(OctS) sulfonate molecules in the gas phase have been investigated by electrospray ionization mass spectrometry, energy-resolved mass spectrometry and density functional theory (DFT) calculations. The experimental results show that the center-of-mass collision energy required to dissociate 50% of these mono-charged aggregates scantly depends on the length of the alkyl chain as well as on the aggregation number. This, together with the large predominance of mono-charged species in the mass spectra, was rationalized i…
Waveguiding properties of a photonic crystal fiber with a solid core surrounded by four large air holes
2009
The polarization-dependent guiding properties of a hexagonal-lattice photonic crystal fiber with a solid-core surrounded by four large air holes are investigated. The appearance of a polarization dependent cutoff frequency, together with several parameters as the birefringence, the modal effective area, the group velocity dispersion and the polarization dependent loss are analyzed. A collection of fibers with different structural parameters were fabricated and characterized. An effective anti-guide structure from at least 450 nm to 1750 nm, a polarizing fiber with a polarization dependent loss of 16 dB/m at 1550 nm, and an endlessly singlemode polarization-maintaining fiber with group biref…