Search results for " cardiac"
showing 10 items of 523 documents
ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA
2009
This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…
Cardiac kinematic parameters computed from video of in situ beating heart
2017
AbstractMechanical function of the heart during open-chest cardiac surgery is exclusively monitored by echocardiographic techniques. However, little is known about local kinematics, particularly for the reperfused regions after ischemic events. We report a novel imaging modality, which extracts local and global kinematic parameters from videos of in situ beating hearts, displaying live video cardiograms of the contraction events. A custom algorithm tracked the movement of a video marker positioned ad hoc onto a selected area and analyzed, during the entire recording, the contraction trajectory, displacement, velocity, acceleration, kinetic energy and force. Moreover, global epicardial veloc…
Percutaneous closure of left atrial appendage to prevent embolic events in high-risk patients with chronic atrial fibrillation
2009
Background: Percutaneous closure of the left atrial appendage (LAA) is a novel alternative for the treatment of patients with atrial fibrillation (AF) and with a high risk of stroke who are not eligible for long-term anticoagulation therapy. The aim of this study was to asses the safety, feasibility, and long-term efficacy of this procedure. Methods: From July 2004 to June 2007, 20 patients (13 male, mean age 69 ± 8 years) with non–valvular AF (NV-AF) underwent LAA percutaneous closure using the PLAATO™ system, implanted through a transeptal access. All patients had contraindications to anticoagulant therapy and were at high risk for cardioembolic stroke (mean CHADS2 score 3 ± 1.2). A trans…
Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
2013
Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…
Transcatheter Mitral Valve Repair: Single Stage Combo Approach
2019
Standardized Model of Ventricular Fibrillation and Advanced Cardiac Life Support in Swine
2020
Cardiopulmonary resuscitation after cardiac arrest, independent of its origin, is a regularly encountered medical emergency in hospitals as well as preclinical settings. Prospective randomized trials in human subjects are difficult to design and ethically ambiguous, which results in a lack of evidence-based therapies. The model presented in this report represents one of the most common causes of cardiac arrests, ventricular fibrillation, in a standardized setting in a large animal model. This allows for reproducible observations and various therapeutic interventions under clinically accurate conditions, hence facilitating the generation of better evidence and eventually the potential for im…
Heart rate turbulence for guiding electric therapy in patients with cardiac failure
2009
It is well-known that a reduction of the cardiac frequency variability, measurable with the Heart Rate Variability (HRV) system, is an indirect expression of the sympathetic-autonomic tone. Another index, Heart Rate Turbulence (HRT), has been recently suggested as a possible unit of measurement for the sympathetic-autonomic tone: this system allows to estimate the baro-reflex response of the carotid arteries to an early ventricular extra-systole by analysing heart rate variations induced by a premature beat.In our research we have analyzed this phenomenon in patients affected by moderate or severe cardiac failure. In particular, we divided 110 patients into two arms: subjects with or withou…
Arrhythmias and inhibition of noradrenaline uptake caused by tricyclic antidepressants and chlorpromazine on the isolated perfused rabbit heart
1975
1. Isolated rabbit hearts were perfused with a modified Tyrode solution containing noradrenaline in concentrations increasing stepwise from 5.9 nM to 5.9 μM at 5 min intervals. This dose regime was applied twice before and once 20 min after starting perfusion with one of 9 tricyclic drugs. Ventricular rate and right atrial and ventricular tensions were recorded using the transverse method. 2. Infusions of noradrenaline evoked ventricular arrhythmias in hearts perfused with amitriptyline 4.8 μM, chlorpromazine 5.0 μM, desipramine 5.0 μM, dibenzepine 34.7 μM, doxepin 4.7 μM, imipramine 4.7 μM, noxiptiline 9.1 μM and opipramole 9.2 μM. The incidence of arrhythmias increased with the concentrat…
ICD Implantation in infants and small children: the extracardiac technique.
2007
There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…
Lack of effect of azithromycin on QT interval in children: a cohort study.
2016
Macrolides are a group of antimicrobial drugs used widely, being well known for their adverse cardiac effects. Erythromycin and clarithromycin are most commonly associated with these conditions. In recent years, azithromycin (AZM) has been assessed because of its possible relation to arrhythmias (mainly QT interval prolongation) and risk of cardiovascular death.1 The pharmacodynamics of these effects is complex and the occurrence of cardiovascular death is unpredictable.2 However, all published manuscripts on the cardiac effects of AZM to date are cases in adults or …