Agreement between intraoperative anterior segment spectral-domain OCT and 2 swept-source OCT biometers.
2021
Purpose: To evaluate the agreement of different biometric parameters obtained using intraoperative spectral-domain optical coherence tomography (SD-OCT) and two swept-source optical coherence tomog...
Assessment of anterior segment measurements using a high-resolution imaging device
2020
To assess the repeatability of several anterior segment parameters obtained with swept-source optical coherence tomography (SS-OCT).We measured 5-times consequently several parameters in 69 eyes using the ANTERION SS-OCT. White-to-white (WTW), angle-to-angle (ATA), spur-to-spur (STS), and lens vault distances were measured in the horizontal- and vertical-meridian. Anterior-chamber-angle (ACA), scleral-spur-angle (SSA), angle-opening-distance (AOD), and trabecular-iris-space-area (TISA) were measured at 500 and 750 μm for the superior-, nasal-,inferior-, and temporal-quadrants. Intrasubject standard deviation (Sw),coefficient of variation (CoV), coefficient of repeatability (CoR), and intrac…
Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.
2007
To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…
Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
2012
PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…
Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation
2007
Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…
Refractive changes in nuclear, cortical and posterior subcapsular cataracts. Effect of the type and grade
2015
Purpose: To determine the effect of main morphological types and grades of age-related cataracts on refractive error. Methods: We measured 276 subjects with optical compensation prior to the development of cataract. We evaluated 224 eyes with nuclear cataract, 125 with cortical cataract, and 103 with posterior subcapsular (PSC) cataract classified with LOCSIII. We measured visual acuity (VA) with their spectacles and best-corrected visual acuity (BCVA) with chart in decimal scale to obtain the optimal compensation with cataract. We evaluated the differences between compensations. Results: A significant myopic shift was observed in nuclear cataract from low to mild grade (p = 0.031), the sam…
Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens
2007
To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…
Effect of large positioning holes on capsule fixation of plate-haptic intraocular lenses
2000
Abstract Purpose To compare the centration and fixation of silicone plate-haptic intraocular lenses (IOLs) with different-sized positioning holes. Setting Eye Clinic of the Johannes Gutenberg-University Mainz, Mainz, Germany. Methods In a prospective randomized study, 51 Chiroflex C10 and 56 Chiroflex C11 IOLs were implanted under standardized conditions by the same surgeon. The IOL position was documented at the end of surgery and by retroillumination on the first day and 5 months postoperatively. The positioning-hole area was evaluated by ultrasound biomicroscopy (50 MHz) 5 months postoperatively. Results One day postoperatively, no IOL in either group was decentered more than 1.0 mm. Aft…
Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation
2003
Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…
Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
2005
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…