Search results for " hysteresis"
showing 10 items of 98 documents
Electromagnetic response of LaO_0.94F_0.06FeAs: AC susceptibility and microwave surface resistance
2009
We discuss on the electromagnetic response of a polycrystalline sample of LaO_0.94F_0.06FeAs exposed to DC magnetic fields up to 10 kOe. The low- and high-frequency responses have been investigated by measuring the AC susceptibility at 100 kHz and the microwave surface resistance at 9.6 GHz. At low as well as high DC magnetic fields, the susceptibility strongly depends on the amplitude of the AC driving field, highlighting enhanced nonlinear effects. The field dependence of the AC susceptibility exhibits a magnetic hysteresis that can be justified considering the intragrain-field-penetration effects on the intergrain critical current density. The microwave surface resistance exhibits a cloc…
Exploring the High-Temperature Frontier in Molecular Nanomagnets: From Lanthanides to Actinides.
2019
Molecular nanomagnets based on mononuclear metal complexes, also known as single-ion magnets (SIMs), are crossing challenging boundaries in molecular magnetism. From an experimental point of view, this class of magnetic molecules has expanded from lanthanoid complexes to both d-transition metal and actinoid complexes. From a theoretical point of view, more and more improved models have been developed, and we are now able not only to calculate the electronic structure of these systems on the basis of their molecular structures but also to unveil the role of vibrations in the magnetic relaxation processes, at least for lanthanoid and d-transition metal SIMs. This knowledge has allowed us to o…
Magnetic characteristics of industrial dust from different sources of emission: A case study of Poland
2015
Abstract Dust emission and deposition in topsoil have negative effect on individual components of the ecosystem. In addition to routine geochemical analyses, magnetic measurements may provide useful complementary information related to the type, concentration and grain-size distribution of the technogenic magnetic particles (TMPs) and thus the degree of contamination of the environment. The aim of this contribution is to use magnetic parameters in distinguishing dust from a wide range of sources of air pollution (power industry, cement, coke, ceramic industries and biomass combustion). We measured magnetic susceptibility, hysteresis parameters and thermomagnetic curves. Our results suggest …
Dynamic Preisach Hysteresis Model for Magnetostrictive Materials for Energy Application
2013
Essential Measurements for Finite Element Simulations of Magnetostrictive Materials
2018
We discuss which magnetoelastic material properties are essential to measure in order to model magnetostrictive materials in finite element simulations. We show knowing the magnetic constitutive relation is sufficient, if the elastic behavior without magnetic field is known a priori. We neglect hysteresis, and our starting point is to express the effect of mechanical deformation on the magnetic constitutive relation with a small strain tensor and magnetic flux density. It follows that the (energetic) state of a magnetostrictive material is independent of its history. Then, a certain choice of history allows us to keep magnetism and elasticity distinct. We demonstrate with open source softwa…
Influence of Corneal Opacity on Intraocular Pressure Assessment in Patients with Lysosomal Storage Diseases
2017
Aims To investigate an influence of mucopolysaccharidosis (MPS)- and Morbus Fabry-associated corneal opacities on intraocular pressure (IOP) measurements and to evaluate the concordance of the different tonometry methods. Methods 25 MPS patients with or without corneal clouding, 25 Fabry patients with cornea verticillata ≥ grade 2 and 25 healthy age matched controls were prospectively included into this study. Outcome measures: Goldmann applanation tonometry (GAT); palpatory assessment of IOP; Goldmann-correlated intraocular pressure (IOPg), corneal-compensated intraocular pressure (IOPcc), corneal resistance factor (CRF) and corneal hysteresis (CH) assessed by Ocular Response Analyzer (ORA…
Anterior Segment Biometry and Their Correlation with Corneal Biomechanics in Caucasian Children.
2018
Purpose: To assess the relationship between the corneal biomechanical parameters and the anterior segment parameters in Caucasian children. Methods: This study included 293 eyes from 293 healthy children aged between 6 and 17 years. Corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer, axial length (AL) with IOLMaster and the anterior segment with Pentacam. Anterior segment parameters obtained were the following: central corneal thickness (CCT), corneal volume (CV), anterior chamber depth (ACD), anterior chamber volume (ACV) and mean anterior and posterior keratometry. Two multiple linear regression models were constructed to assess th…
Permeability measurements in cobalt ferrite and carbonyl iron powders and suspensions
2002
Abstract Magnetic permeability data of cobalt ferrite and carbonyl iron suspensions are discussed. Using an induction method, the relative differential permeability, μr,dif, was measured as a function of the internal magnetic field for different volume fractions of the solid phase. In the case of cobalt ferrite suspensions, the μr,dif−H curve was obtained for a first increasing ramp of magnetic field (data series “1”), a decreasing ramp (data series “2”), and the second increasing one (data series “3”). Series “1” showed a maximum in the μr,dif−H trend that did not appear in series “2” and “3”. Furthermore, the data in series “2” and “3” are always below those in series “1”. The latter beha…
Strain-controlled domain wall injection into nanowires for sensor applications
2021
We investigate experimentally the effects of externally applied strain on the injection of 180$^\circ$ domain walls (DW) from a nucleation pad into magnetic nanowires, as typically used for DW-based sensors. In our study the strain, generated by substrate bending, induces in the material a uniaxial anisotropy due to magnetoelastic coupling. To compare the strain effects, $Co_{40}Fe_{40}B_{20}$, $Ni$ and $Ni_{82}Fe_{18}$ samples with in-plane magnetization and different magnetoelastic coupling are deposited. In these samples, we measure the magnetic field required for the injection of a DW, by imaging differential contrast in a magneto-optical Kerr microscope. We find that strain increases t…
Characterization and magnetic properties of nanoparticles based on FePt solid solution with an oxide shell
2015
Abstract We present the results of magnetic properties investigations of ferromagnetic nanoparticles which ensembled with ferromagnetic shell. The aim of this work is to study the connection of structure–phase composition and thermal treatment with the magnetic properties, partially, with the coercive force and the exchange bias field in a two-dimension spin system of core–shell type. It is found that the exchange bias field increases with the growth of the oxide shell thickness. This is realized by annealing in a dosed oxygen flow. The decrease of the coercive force with the increase of annealing temperature is connected with the concentration effect (the concentration of ferromagnetic par…