Search results for " method"
showing 10 items of 10455 documents
Simulations and measurements of beam loss patterns at the CERN Large Hadron Collider
2014
The CERN Large Hadron Collider (LHC) is designed to collide proton beams of unprecedented energy, in order to extend the frontiers of high-energy particle physics. During the first very successful running period in 2010-2013, the LHC was routinely storing protons at 3.5-4 TeV with a total beam energy of up to 146 MJ, and even higher stored energies are foreseen in the future. This puts extraordinary demands on the control of beam losses. An uncontrolled loss of even a tiny fraction of the beam could cause a superconducting magnet to undergo a transition into a normal-conducting state, or in the worst case cause material damage. Hence a multistage collimation system has been installed in ord…
Pulsating in Unison at Optical and X-Ray Energies: Simultaneous High Time Resolution Observations of the Transitional Millisecond Pulsar PSR J1023+00…
2019
PSR J1023+0038 is the first millisecond pulsar discovered to pulsate in the visible band; such a detection took place when the pulsar was surrounded by an accretion disk and also showed X-ray pulsations. We report on the first high time resolution observational campaign of this transitional pulsar in the disk state, using simultaneous observations in the optical (TNG, NOT, TJO), X-ray (XMM-Newton, NuSTAR, NICER), infrared (GTC) and UV (Swift) bands. Optical and X-ray pulsations were detected simultaneously in the X-ray high intensity mode in which the source spends $\sim$ 70% of the time, and both disappeared in the low mode, indicating a common underlying physical mechanism. In addition, o…
Multivariate standardisation for non-linear calibration range in the chemiluminescence determination of chromium.
2006
Multivariate standardisation is proposed for the successful chemiluminescence determination of chromium based on luminol-hydrogen peroxide reaction. In an extended concentration range, non-linear calibration model is needed. The studied instrumental situations were different detection cells, instruments, assemblies, time and their possible combinations. Chemiluminescence kinetic registers have been transferred using piecewise direct standardisation (PDS) method. The optimisation of transfer parameters has been carried out based on the prediction residual error criteria. Non-linear principal component regression (NL-PCR) and non-linear partial least square regression (NL-PLS) were chosen for…
Gaia -ESO Survey: Analysis of pre-main sequence stellar spectra
2015
This paper describes the analysis of UVES and GIRAFFE spectra acquired by the Gaia-ESO Public Spectroscopic Survey in the fields of young clusters whose population includes pre-main sequence (PMS) stars. Both methods that have been extensively used in the past and new ones developed in the contest of the Gaia-ESO survey enterprise are available and used. The internal precision of these quantities is estimated by inter-comparing the results obtained by such different methods, while the accuracy is estimated by comparison with independent external data, like effective temperature and surface gravity derived from angular diameter measurements, on a sample of benchmarks stars. Specific strategi…
Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes
2009
Purpose: We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. Methods: Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. Results: Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied …
Use of the modified quick easy cheap effective rugged and safe sample preparation approach for the simultaneous analysis of type A- and B-trichothece…
2010
A suitable extraction and purification method for the simultaneous liquid chromatography-mass spectrometry (LC-MS) determination of five mycotoxins, three type A, diacetoxyscirpenol (DAS), T-2 toxin (T-2) and HT-2 toxin (HT-2), and two type B-trichothecenes, deoxynivalenol (DON) and nivalenol (NIV), has been optimised using a modified "Quick Easy Cheap Effective Rugged and Safe" (QuEChERS) method. Different solvents were studied in the extraction procedure to obtain better recoveries, which ranged from 86 to 108%, using a 85/15 (v/v) mixture of methanol/acetonitrile. The values obtained for recovery, repeatability and reproducibility of the optimized method are in agreement with Commission …
Dissemination of a Carbapenem-Resistant Acinetobacter baumannii Strain Belonging to International Clone II/Sequence Type 2 and Harboring a Novel AbaR…
2013
ABSTRACT An outbreak of hospital-acquired Acinetobacter baumannii infections, caused by a bla OXA-23 -positive carbapenem-resistant strain belonging to international clone II/ST2, was detected in Latvia. The strain was partially equipped with the armA gene and the intI1-aacA4-catB8-aadA1-qacE Δ 1 class 1 integron. In addition, the strain carried AbaR25, a novel AbaR4-like resistance island of ∼46,500 bp containing structures similar to the previously described AbaR22 and Tn 6167 islands. AbaR25 was characterized by the occurrence of a second copy of Tn 6022a interrupted by Tn 2006 carrying the bla OXA-23 gene.
Measurement of acoustic attenuation in South Pole ice
2010
Using the South Pole Acoustic Test Setup (SPATS) and a retrievable transmitter deployed in holes drilled for the IceCube experiment, we have measured the attenuation of acoustic signals by South Pole ice at depths between 190 m and 500 m. Three data sets, using different acoustic sources, have been analyzed and give consistent results. The method with the smallest systematic uncertainties yields an amplitude attenuation coefficient alpha = 3.20 \pm 0.57 km^(-1) between 10 and 30 kHz, considerably larger than previous theoretical estimates. Expressed as an attenuation length, the analyses give a consistent result for lambda = 1/alpha of ~1/300 m with 20% uncertainty. No significant depth or …
Technical Note: Prediction Models of Airborne Sound Insulation of Multilayer Materials with Viscoelastic Thin Sheets
2008
The growing introduction of new insulation materials in building acoustics has caused an increase of the importance of the prediction tools. Appropriate simulations allow strictly necessary laboratory measurements to be identified. In this way, costs are reduced. The demands of new legislation has resulted in the appearance of various software designed to facilitate prediction. The prediction models are based on different hypotheses: adaptation of impedances, spatial behaviour of spectral components, statistical energy distribution, the Finite Element Method (FEM), etc. Each of these models and methods offer advantages and contain limitations. In this paper, different models for prediction…
A SYMMETRIC AND POSITIVE DEFINITE BEM FOR 2-D FORCED VIBRATIONS
1997
A BEM formulation for 2D elastodynamics in the time domain has been presented. The formulation gives a resolving system that involves boundary displacements only. The stiffness and mass matrices of the boundary discretized body are frequency independent, symmetric and positive definite