Search results for " microscopy"
showing 10 items of 1617 documents
Use of flow cytometry and confocal microscopy techniques to investigate early CdCl(2)-induced nephrotoxicity in vitro.
2001
CdCl(2) is a well-known toxic compound for the kidney in vivo and in vitro. We report here part of the results of an ECVAM (European Centre for the Validation of Alternative Methods) contract study, aimed at establishing and assessing several flow cytometric and confocal microscopic endpoints for use in an in vitro nephrotoxicity model. Three renal tubule cell lines, OK (opossum, proximal tubule origin), LLC-PK1 (pig, proximal tubule origin) and MDCK (dog, distal tubule origin) were exposed for 1, 5 and 24 h to 25 microM and 100 microM CdCl(2). The results obtained for mitochondrial membrane potential showed a decrease in all the cell lines after 5 h of treatment with both CdCl(2) concentra…
Functional Adhesion of Pectin Biopolymers to the Lung Visceral Pleura
2021
Pleural injuries and the associated “air leak” are the most common complications after pulmonary surgery. Air leaks are the primary reason for prolonged chest tube use and increased hospital length of stay. Pectin, a plant-derived heteropolysaccharide, has been shown to be an air-tight sealant of pulmonary air leaks. Here, we investigate the morphologic and mechanical properties of pectin adhesion to the visceral pleural surface of the lung. After the application of high-methoxyl citrus pectin films to the murine lung, we used scanning electron microscopy to demonstrate intimate binding to the lung surface. To quantitatively assess pectin adhesion to the pleural surface, we used a custom ad…
Topology of the 10 subunits within the decamer of KLH, the hemocyanin of the marine gastropod Megathura crenulata.
2002
Immunoelectron microscopy has been performed using negatively stained immune complexes of keyhole limpet hemocyanin isoform 1 (KLH1) decamers and a functional unit-specific monoclonal antibody anti-KLH1-c1. The antibody links hemocyanin molecules at both the collar and the collarless edge of the decamer, indicating a peripheral localization of functional units c. In isoform 2 (KLH2) the positions of functional units c have been identified with the peanut agglutinin (PNA), which has previously been shown to exclusively bind to KLH2-c. Ferritin linked to PNA was used to visualize labeled molecules electron microscopically. The pattern of labeling also indicates a peripheral localization of th…
Water-Dependent Blending of Pectin Films: The Mechanics of Conjoined Biopolymers
2020
Biodegradable pectin polymers have been recommended for a variety of biomedical applications, ranging from the delivery of oral drugs to the repair of injured visceral organs. A promising approach to regulate pectin biostability is the blending of pectin films. To investigate the development of conjoined films, we examined the physical properties of high-methoxyl pectin polymer-polymer (homopolymer) interactions at the adhesive interface. Pectin polymers were tested in glass phase (10&ndash
Effect of Morphology and Size of Halloysite Nanotubes on Functional Pectin Bionanocomposites for Food Packaging Applications
2017
Pectin bionanocomposite films filled with various concentrations of two different types of halloysite nanotubes were prepared and characterized in this study as potential films for food packaging applications. The two types of halloysite nanotubes were long and thin (patch) (200-30 000 nm length) and short and stubby (Matauri Bay) (50-3000 nm length) with different morphological, physical, and dispersibility properties. Both matrix (pectin) and reinforcer (halloysite nanotubes) used in this study are considered as biocompatible, natural, and low-cost materials. Various characterization tests including Fourier transform infrared spectroscopy, field emission scanning electron microscopy, rele…
Magnetization dynamics in polycrystalline Permalloy and epitaxial Co platelets observed by time-resolved photoemission electron microscopy
2009
We studied the dynamic magnetization response in rectangular polycrystalline Permalloy and also epitaxial Co structures (lateral sizes comprised tens of microns at a thickness of tens of nanometers) during the action of a magnetic field pulse, using time-resolved X-ray photoemission electron microscopy with a time resolution of 10 ps. In the case of Permalloy platelets the restoring torque that is necessary for the stroboscopic image acquisition is provided by the Landau flux closure structure representing a minimum of the free energy. We investigated the dynamic response of 90° Neel domain walls. The main results are: the maximum velocity of the domain wall is 1.5 × 104 m/s, the intrinsic …
Sub-nanosecond resolution x-ray magnetic circular dichroism photoemission electron microscopy of magnetization processes in a permalloy ring
2005
Fast magnetization processes in a microstructured permalloy ring with 80 µm o.d. and 30 nm thickness have been observed by photoemission electron microscopy exploiting x-ray magnetic circular dichroism as the magnetic contrast mechanism. As a high speed probe we employed synchrotron radiation pulses at the ESRF (Grenoble) operated in 16-bunch mode, yielding photon pulses of 105 ps FWHM with a period of 176 ns. Fast magnetic field pulses have been generated by means of current pulses through coplanar waveguides with the magnetic structure being lithographically prepared on their surface. A stroboscopic pump–probe set-up with a variable time delay between the field pulse and photon pulse allo…
Time-resolved X-ray photoemission electron microscopy: imaging magnetodynamics on the 100 ps scale and below
2005
Abstract We present recent results of time-resolved X-ray photoemission electron microscopy (TR-XPEEM) investigations on magnetic systems. Our studies of microstructured permalloy particles employ a magnetic pump XPEEM probe approach. The stroboscopic experiments feature a time resolution of Δ τ ≤ 130 ps and yield magnetic domain images with a surprising richness of details. We observe a strong influence of incoherent magnetization rotation processes, which lead to complicated transient domain structures with a blocked relaxation behavior.
Stroboscopic XMCD–PEEM imaging of standing and propagating spinwave modes in permalloy thin-film structures
2007
Abstract Using synchrotron-based stroboscopic photoemission electron microscopy with X-ray circular dichroism as contrast method, we have investigated the high-frequency response of permalloy thin-film structures. Standing precessional modes have been studied in rectangular elements (16 × 32 μm 2 , 10 nm thick) with a high time resolution of about 15 ps in the low- α mode of BESSY. With increasing amplitude of the applied magnetic AC field the particle is driven from an initial symmetric Landau flux-closure state into an asymmetric state and finally into a single-domain state magnetized perpendicular to the applied field H AC . The electromagnetic microwave field thus can induces a net magn…
Quantitative measurements of magnetic stray field dynamics of Permalloy particles in a photoemission electron microscopy
2010
By example of a Permalloy particle (40 × 40 μm(2) size, 30 nm thickness) we demonstrate a procedure to quantitatively investigate the dynamics of magnetic stray fields during ultrafast magnetization reversal. The measurements have been performed in a time-resolving photoemission electron microscope using the X-ray magnetic circular dichroism. In the particle under investigation, we have observed a flux-closure-dominated magnetic ground structure, minimizing the magnetic stray field outside the sample. A fast magnetic field pulse introduced changes in the micromagnetic structure accompanied with an incomplete flux closure. As a result, stray fields arise along the edges of domains, which cau…