Search results for " resolution"
showing 10 items of 1159 documents
Tracking Moving Objects With a Catadioptric Sensor Using Particle Filter
2011
International audience; Visual tracking in video sequences is a widely developed topic in computer vision applications. However, the emergence of panoramic vision using catadioptric sensors has created the need for new approaches in order to track an object in this type of images. Indeed the non-linear resolution and the geometric distortions due to the insertion of the mirror, make tracking in catadioptric images a very challenging task. This paper describes particle filter for tracking moving object over time using a catadioptric sensor. In this work different problems due to the specificities of the catadioptric systems such as geometry are considered. The obtained results demonstrate an…
Low-Cost Optical Mapping Systems for Panoramic Imaging of Complex Arrhythmias and Drug-Action in Translational Heart Models.
2017
[EN] Panoramic optical mapping is the primary method for imaging electrophysiological activity from the entire outer surface of Langendorff-perfused hearts. To date, it is the only method of simultaneously measuring multiple key electrophysiological parameters, such as transmembrane voltage and intracellular free calcium, at high spatial and temporal resolution. Despite the impact it has already had on the fields of cardiac arrhythmias and whole-heart computational modeling, present-day system designs precludes its adoption by the broader cardiovascular research community because of their high costs. Taking advantage of recent technological advances, we developed and validated low-cost opti…
Comparison between iMSD and 2D-pCF analysis for molecular motion studies on in vivo cells: The case of the epidermal growth factor receptor.
2018
Image correlation analysis has evolved to become a valuable method of analysis of the diffusional motion of molecules in every points of a live cell. Here we compare the iMSD and the 2D-pCF approaches that provide complementary information. The iMSD method provides the law of diffusion and it requires spatial averaging over a small region of the cell. The 2D-pCF does not require spatial averaging and it gives information about obstacles for diffusion at pixel resolution. We show the analysis of the same set of data by the two methods to emphasize that both methods could be needed to have a comprehensive understanding of the molecular diffusional flow in a live cell.
Portable remote photoplethysmography device for monitoring of blood volume changes with high temporal resolution
2016
The compact remote photoplethysmography device for monitoring of blood volume pulsations from human skin were developed. The prototype device comprises electronics board with twelve circullary oriented bright near-infrared LED illuminators, which are precisely controlled, high-speed video camera and battery charging circuit. Device was tested in laboratory and could be used for non-contact monitoring of human blood volume changes in palm.
Imaging Bacterial Colonies and Phage-Bacterium Interaction at Sub-Nanometer Resolution Using Helium-Ion Microscopy
2017
Imaging of microbial interactions has so far been based on well‐established electron microscopy methods. This study presents a new way to study bacterial colonies and interactions between bacteria and their viruses, bacteriophages (phages), in situ on agar plates using helium ion microscopy (HIM). In biological imaging, HIM has advantages over traditional scanning electron microscopy with its sub‐nanometer resolution, increased surface sensitivity, and the possibility to image nonconductive samples. Furthermore, by controlling the He beam dose or by using heavier Ne ions, the HIM instrument provides the possibility to mill out material in the samples, allowing for subsurface imaging and in …
pH-sensitive vibrational probe reveals a cytoplasmic protonated cluster in bacteriorhodopsin
2017
Infrared spectroscopy has been used in the past to probe the dynamics of internal proton transfer reactions taking place during the functional mechanism of proteins but has remained mostly silent to protonation changes in the aqueous medium. Here, by selectively monitoring vibrational changes of buffer molecules with a temporal resolution of 6 µs, we have traced proton release and uptake events in the light-driven proton-pump bacteriorhodopsin and correlate these to other molecular processes within the protein. We demonstrate that two distinct chemical entities contribute to the temporal evolution and spectral shape of the continuum band, an unusually broad band extending from 2,300 to well…
Three-dimensional multiple-particle tracking with nanometric precision over tunable axial ranges
2017
The precise localization of nanometric objects in three dimensions is essential to identify functional diffusion mechanisms in complex systems at the cellular or molecular level. However, most optical methods can achieve high temporal resolution and high localization precision only in two dimensions or over a limited axial (z) range. Here we develop a novel wide-field detection system based on an electrically tunable lens that can track multiple individual nanoscale emitters in three dimensions over a tunable axial range with nanometric localization precision. The optical principle of the technique is based on the simultaneous acquisition of two images with an extended depth of field while …
View images with unprecedented resolution in integral microscopy
2018
Integral microscopy is a novel technique that allows the simultaneous capture of multiple perspective images of microscopic samples. This feature is achieved at the cost of a significant reduction of the spatial resolution. In fact, it is assumed that in the best cases the resolution is reduced by a factor that is not smaller than ten, what poses a hard drawback to the utility of the technique. However, to the best of our knowledge, this resolution limitation has never been researched rigorously. For this reason, the aim of this paper is to explore the real limitations in resolution of integral microscopy and to obtain optically, without the need of any image-processing algorithm, perspecti…
A Single-sensor High-resolution Panoramic Optical Mapping Configuration for Simultaneous Non-overlapped Complete Atrial and Ventricular Parametric Im…
2017
Nowadays optical mapping (OM) is the primary method for imaging electrophysiologically relevant parameters from the outer surface of Langendorff-perfused hearts. This technique has become essential for comprehensively understanding mechanisms of cardiac propagation during physiological activation, arrhythmia, and therapeutic antiarrhythmic interventions in translational hearts. Panoramic whole heart optical mapping systems, using either multiple cameras, plane mirrors or a combination of both, have been developed to overcome intrinsic visualization limitations to traditional single-sensor designs. However current panoramic OM systems are financially challenging for physiology and engineerin…
Automatic detection and measurement of nuchal translucency.
2017
In this paper we propose a new methodology to support the physician both to identify automatically the nuchal region and to obtain a correct thickness measurement of the nuchal translucency. The thickness of the nuchal translucency is one of the main markers for screening of chromosomal defects such as trisomy 13, 18 and 21. Its measurement is performed during ultrasound scanning in the first trimester of pregnancy. The proposed methodology is mainly based on wavelet and multi resolution analysis. The performance of our method was analysed on 382 random frames, representing mid-sagittal sections, uniformly extracted from real clinical ultrasound videos of 12 patients. According to the groun…