Search results for "030218 nuclear medicine & medical imaging"

showing 10 items of 1054 documents

Re: Daniel E. Spratt, Hebert A. Vargas, Zachary S. Zumsteg, et al. Patterns of Lymph Node Failure after Dose-escalated Radiotherapy: Implications for…

2017

medicine.medical_specialtybusiness.industryUrologymedicine.medical_treatment030218 nuclear medicine & medical imagingSurgeryFunctional imagingRadiation therapy03 medical and health sciences0302 clinical medicinemedicine.anatomical_structure030220 oncology & carcinogenesismedicineRadiologybusinessLymph nodeEuropean Urology
researchProduct

Bowel ultrasonography in acute abdomen: beyond acute appendicitis.

2021

Acute abdomen is a common reason for consultation in the emergency department. A broad spectrum of entities, including diverse diseases of the gastrointestinal tract, can cause acute abdomen. Although computed tomography is the technique most widely used to evaluate acute abdomen in the emergency department, abdominal ultrasound is often performed first and allows bowel disease to be suspected. This article describes the ultrasound features of diverse bowel diseases that can cause acute abdomen, such as acute diverticulitis, bowel obstruction, gastrointestinal perforation, bowel ischemia, intraabdominal fat necrosis, and miscellaneous processes such as endometriosis, foreign bodies, or vasc…

medicine.medical_specialtybusiness.industrydigestive oral and skin physiologyDiverticulitismedicine.diseaseInflammatory bowel diseasedigestive system diseases030218 nuclear medicine & medical imagingBowel obstruction03 medical and health sciences0302 clinical medicineMesenteric ischemiaAcute abdomenGastrointestinal perforation030220 oncology & carcinogenesismedicineGeneral Earth and Planetary SciencesHerniaFat necrosisRadiologymedicine.symptombusinessGeneral Environmental ScienceRadiologia
researchProduct

MR Imaging of Perianal Crohn Disease: The Role of Contrast-enhanced Sequences

2017

The MR imaging protocol described by the authors includes contrast-enhanced T1-weighted imaging with fat saturation in all patients except those with poor renal function. Horsthuis et al demonstrated in 2009 the usefulness of contrast-enhanced MR imaging for determining disease activity. Contrast agent administration is also required in case of suspicion of neoplastic tissue complicating fistulas. The joint European Crohn’s and Colitis Organisation–European Society of Gastointestinal and Abdominal Radiology guidelines report that T2-weighted images and contrast-enhanced T1-weighted images are included in the MR imaging protocol for the evaluation of perianal CD. However, as we have demonstr…

medicine.medical_specialtybusiness.industrymedia_common.quotation_subjectMR STIRContrast MediaMagnetic Resonance ImagingMr imaging030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineText miningCrohn DiseasePerianal Crohn diseasemedicineHumansContrast (vision)030211 gastroenterology & hepatologyRadiology Nuclear Medicine and imagingRadiologybusinessmedia_common
researchProduct

Prescription Depth in Surface Skin Brachytherapy

2017

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentBrachytherapy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOncology030220 oncology & carcinogenesisMedicineRadiology Nuclear Medicine and imagingRadiologyMedical prescriptionbusinessBrachytherapy
researchProduct

2014

Background and purpose: A substantial reduction of uncertainties in clinical brachytherapy should result in improved outcome in terms of increased local control and reduced side effects. Types of uncertainties have to be identified, grouped, and quantified. Methods: A detailed literature review was performed to identify uncertainty components and their relative importance to the combined overall uncertainty. Results: Very few components (e.g., source strength and afterloader timer) are independent of clinical disease site and location of administered dose. While the influence of medium on dose calculation can be substantial for low energy sources or non-deeply seated implants, the influence…

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentBrachytherapyDose fractionationHematologySchedule (project management)Clinical disease030218 nuclear medicine & medical imaging3. Good health03 medical and health sciences0302 clinical medicineOncology030220 oncology & carcinogenesisAbsorbed doseTotal dosemedicineDosimetryRadiology Nuclear Medicine and imagingMedical physicsRadiation treatment planningbusinessRadiotherapy and Oncology
researchProduct

1-Year Outcomes of FFRCT-Guided Care in Patients With Suspected Coronary Disease

2016

Abstract Background Coronary computed tomographic angiography (CTA) plus estimation of fractional flow reserve using CTA (FFR CT ) safely and effectively guides initial care over 90 days in patients with stable chest pain. Longer-term outcomes are unknown. Objectives The study sought to determine the 1-year clinical, economic, and quality-of-life (QOL) outcomes of using FFR CT instead of usual care. Methods Consecutive patients with stable, new onset chest pain were managed by either usual testing (n = 287) or CTA (n = 297) with selective FFR CT (submitted in 201, analyzed in 177); 581 of 584 (99.5%) completed 1-year follow-up. Endpoints were adjudicated major adverse cardiac events (MACE) …

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentFractional flow reserve030204 cardiovascular system & hematologymedicine.diseaseChest painRevascularization3. Good health030218 nuclear medicine & medical imagingCoronary artery disease03 medical and health sciences0302 clinical medicineQuality of lifeConventional PCIMedicineMyocardial infarctionRadiologymedicine.symptomCardiology and Cardiovascular MedicinebusinessMaceJournal of the American College of Cardiology
researchProduct

Towards clinical application of RayStretch for heterogeneity corrections in LDR permanent 125-I prostate brachytherapy

2017

Purpose RayStretch is a simple algorithm proposed for heterogeneity corrections in low-dose–rate brachytherapy. It is built on top of TG-43 consensus data, and it has been validated with Monte Carlo (MC) simulations. In this study, we take a real clinical prostate implant with 71 125I seeds as reference and we apply RayStretch to analyze its performance in worst-case scenarios. Methods and Materials To do so, we design two cases where large calcifications are located in the prostate lobules. RayStretch resilience under various calcification density values is also explored. Comparisons against MC calculations are performed. Results Dose–volume histogram–related parameters like prostate D90, …

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyProstate implant030218 nuclear medicine & medical imagingIntraoperative ultrasound03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureOncologyPròstataProstate030220 oncology & carcinogenesismedicineDosimetryRadiology Nuclear Medicine and imagingMedical physicsRadiation treatment planningbusinessBraquiteràpiaProstate brachytherapy
researchProduct

Infarct characterization using CT

2017

Myocardial infarction (MI) is a major cause of death and disability worldwide. The incidence is not expected to diminish, despite better prevention, diagnosis and treatment, because of the ageing population in industrialized countries and unhealthy lifestyles in developing countries. Nowadays it is highly requested an imaging tool able to evaluate MI and viability. Technology improvements determined an expansion of clinical indications from coronary plaque evaluation to functional applications (perfusion, ischemia and viability after MI) integrating additional phases and information in the mainstream examination. Cardiac computed tomography (CCT) and cardiac MR (CMR) employ different contra…

medicine.medical_specialtycoronary arterieIschemiaReview Article030204 cardiovascular system & hematologyPharmacological stress030218 nuclear medicine & medical imagingIodinated contrast media03 medical and health sciences0302 clinical medicineImaging Toolcardiovascular diseasemedicineMyocardial infarctionmyocardial infarction (MI)Cause of deathbusiness.industrycomputed tomographymedicine.diseaseCoronary arteriesmedicine.anatomical_structureAtherosclerosiRadiologyCardiology and Cardiovascular MedicinebusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaPerfusionCardiovascular Diagnosis and Therapy
researchProduct

Repair of a spinal pseudomeningocele in a delayed postsurgical cerebrospinal fluid leak using titanium U-clips: Technical note

2020

Abstract Introduction Chronic cerebrospinal fluid leak (CCFL) represents a possible event following spine surgery, with an incidence rate ranging from 5 to 18%. In literature have been reported few modification techniques that involved the use of titanium U-clips with the aim to reduce dural traumatism during its closure but only after non-accidental durotomy. Case illustration We report the case of a 47-year-old female with history of L5-S1 microsurgical discectomy. After one year the patient was admitted to our unit because she presented progressive skin swelling in the lumbar region, intermittent headache and recurrent episodes of lipothymia. One-year MRI showed a voluminous subcutaneous…

medicine.medical_specialtydurotomymedicine.medical_treatmentlcsh:Surgeryspine surgery; durotomy; cerebrospinal fluid leak; titanium; u-clipslcsh:RC346-429030218 nuclear medicine & medical imagingspine surgery03 medical and health sciences0302 clinical medicineCerebrospinal fluidLumbarSuture (anatomy)DiscectomyMedicineu-clipstitaniumlcsh:Neurology. Diseases of the nervous systemProleneCerebrospinal fluid leakbusiness.industrylcsh:RD1-811medicine.diseaseSurgeryPseudomeningoceleSurgeryNeurology (clinical)Pouchbusinesscerebrospinal fluid leak030217 neurology & neurosurgeryInterdisciplinary Neurosurgery
researchProduct

Modelling cardiac mechanics of left ventricular noncompaction

2020

Left ventricular noncompaction (LVNC) can be defined as a cardiomyopathy characterised by a pattern of prominent trabecular structure and deep intertrabecular recesses, that is thought to be caused by an arrest of normal endomyocardial morphogenesis. Using patient-specific computational modelling, we assessed the cardiac mechanics of five patients with LVNC and compared myocardial stress and pump performance to those of healthy controls. Findings shown that patients with LVNC have impaired left ventricular (LV) function, making it possible that the lack of fibre shortening of noncompacted layer can determine poor heart function. Pronounced end-systolic wall stress on left ventricular wall o…

medicine.medical_specialtygenetic structuresBiomedical EngineeringComputational MechanicsCardiomyopathy02 engineering and technology030218 nuclear medicine & medical imaging03 medical and health sciencesWall stress0302 clinical medicinecardiac mechanics finite element analysis Left ventricular noncompaction wall stressInternal medicine0202 electrical engineering electronic engineering information engineeringmedicineRadiology Nuclear Medicine and imagingbusiness.industryfungifood and beveragesmedicine.diseaseComputer Science ApplicationsCardiologyLeft ventricular noncompaction020201 artificial intelligence & image processingsense organsbusinessCardiac mechanics
researchProduct