Search results for "Absorption"

showing 10 items of 2701 documents

Influence of the electro-optical properties of an a-Si:H single layer on the performances of a pin solar cell

2012

We analyze the results of an extensive characterization study involving electrical and optical measurements carried out on hydrogenated amorphous silicon (α-Si:H) thin film materials fabricated under a wide range of deposition conditions. By adjusting the synthesis parameters, we evidenced how conductivity, activation energy, electrical transport and optical absorption of an α-Si:H layer can be modified and optimized. We analyzed the activation energy and the pre-exponential factor of the dark conductivity by varying the dopant-to-silane gas flow ratio. Optical measurements allowed to extract the absorption spectra and the optical bandgap. Additionally, we report on the temperature dependen…

Amorphous siliconThin film materialThin film solar cell Activation energySingle junctionConductivitySettore ING-INF/01 - ElettronicaSettore FIS/03 - Fisica Della Materialaw.inventionchemistry.chemical_compoundElectric conductivitylawMaterials ChemistryThin filmAbsorption (electromagnetic radiation)Preexponential factorGas-flow ratioMetals and AlloysSurfaces and InterfacesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsTemperature dependenceHydrogenated amorphous siliconOptoelectronicsElectric propertieQuantum efficiencyHydrogenationOptical data processingDeposition conditionSiliconMaterials scienceActivation energyQuantum efficiencySynthesis conditionVapor deposition SiliconOpticsSolar cellActivation energyDark conductivityCharacterization studieElectromagnetic wave absorptionThin filmDepositionElectrooptical propertieThin film solar cellConductivitybusiness.industryEnergy conversion efficiencySolar cellAmorphous siliconMeyer-Neldel ruleOptical propertieOptical measurementelectro-optical propertiesNanostructured materialSilicon; Solar cell; electro-optical propertiesElectrical transportchemistrySynthesis parameterOptical variables measurementSingle layerConversion efficiencybusinessOptical gap
researchProduct

Amplified spontaneous emission in thin films of quasi-2D BA3MA3Pb5Br16 lead halide perovskites

2021

Quasi-2D (two-dimensional) hybrid perovskites are emerging as a new class of materials with high photoluminescence yield and improved stability compared to their three-dimensional (3D) counterparts. Nevertheless, despite their outstanding emission properties, few studies have been reported on amplified spontaneous emission (ASE) and a thorough understanding of the photophysics of these layered materials is still lacking. In this work, we investigate the ASE properties of multilayered quasi-2D BA3MA3Pb5Br16 films through the dependence of the photoluminescence on temperature and provide a novel insight into the emission processes of quasi-2D lead bromide perovskites. We demonstrate that the …

Amplified spontaneous emissionPhotoluminescenceMaterials sciencequasi-2D perovskite Amplified spontaneous emission PhotoluminescenceHalideLaserlaw.inventionChemical physicslawPhase (matter)General Materials ScienceThin filmAbsorption (electromagnetic radiation)MaterialsExcitation
researchProduct

Decoding vibrational states of Concanavalin A amyloid fibrils.

2015

International audience; Amyloid and amyloid-like fibrils are a general class of protein aggregates and represent a central topic in life sciences for their involvement in several neurodegenerative disorders and their unique mechanical and supramolecular morphological properties. Both their biological role and their physical properties, including their high mechanical stability and thermodynamic inertia, are related to the structural arrangement of proteins in the aggregates at molecular level. Significant variations may exist in the supramolecular organization of the commonly termed cross-β structure that constitutes the amyloid core. In this context, a fine knowledge of the structural deta…

AmyloidAbsorption spectroscopy[SDV]Life Sciences [q-bio]BiophysicsSupramolecular chemistry02 engineering and technologymacromolecular substancesProtein aggregationAntiparallel (biochemistry)FibrilSpectrum Analysis RamanBiochemistryVibrationProtein Structure Secondary03 medical and health sciencessymbols.namesakeSpectroscopy Fourier Transform InfraredConcanavalin AHumansFourier transform infrared spectroscopyRaman030304 developmental biology0303 health sciencesChemistryOrganic ChemistryIntermolecular force021001 nanoscience & nanotechnologyAmyloid FTIR RAMAN hydration water THz spectroscopy[SDV] Life Sciences [q-bio]CrystallographyFTIRTerahertz spectroscopysymbolsBiophysicsFibrils0210 nano-technologyRaman spectroscopy
researchProduct

The generalized H-point standard-additions method to determine analytes present in two different chemical forms in unknown matrix samples. Part II. C…

2000

The generalized H-point standard-additions method (GHPSAM) is used in order to obtain the total Cr(VI) and chromate concentration in water samples whose matrices are completely unknown. Moreover, a new methodology, which is a modification of the GHPSAM, is proposed for the simultaneous determination of the two major chemical forms of Cr(VI) present in the sample. The method is based on the location of spectral intervals where the behaviour of the interferent absorbance can be considered as linear. From these intervals, the analyte concentration free from bias error can be estimated. Spiked samples of dig and harbour water measured in the UV–visible spectral region have been tested to check …

AnalyteAbsorption spectroscopyChromate conversion coatingChemistryAnalytical chemistryBiochemistryAnalytical ChemistryChemometricsAbsorbanceMatrix (mathematics)Standard additionElectrochemistryEnvironmental ChemistryQuantitative analysis (chemistry)SpectroscopyThe Analyst
researchProduct

Apparent content curves: description and analytical applications. Resolution of binary mixtures

1992

The apparent content curves and their analytical applications are described. Basing on these curves a mathematical method, which permits the identification of the interfering component present in a binary mixture as well as the determination of the contents of both constituents, is proposed. The existence of considerable interaction coefficients is not an impediment for its application. Besides, the analyte contents in the mixture can be obtained without the use of standard interference solutions. The proposed procedure is applied to the analysis of mixtures of dyes with overlapping absorption spectra.

AnalyteAbsorption spectroscopyResolution (mass spectrometry)ChemistryComponent (thermodynamics)Content (measure theory)Analytical chemistryBinary numberInterference (wave propagation)Biological systemBiochemistryAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

High-pressure flow-injection assembly. Indirect determination of glycine by atomic absorption spectrometry.

1991

A procedure for the determination of glycine is described. The method is based on the reaction of the analyte with finely powdered, solid copper(II) carbonate in a continuous-flow assembly. The optimum experimental conditions of pH, temperature, sample volume, flow-rate, column length and internal diameter, and the linear range of calibration, were studied. Interference from foreign substances that accompany this amino acid in pharmaceutical formulations was studied, and the method was applied to the determination of glycine.

AnalyteAnalytical chemistryGlycinechemistry.chemical_elementBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundlawElectrochemistryCalibrationEnvironmental ChemistrySpectroscopychemistry.chemical_classificationChromatographyChemistrySpectrophotometry AtomicTemperatureHydrogen-Ion ConcentrationCopperAmino acidLinear rangeGlycineCarbonic AcidCarbonateIndicators and ReagentsAtomic absorption spectroscopyThe Analyst
researchProduct

X-ray analysis on the nanogram to microgram scale using porous complexes

2012

X-ray single-crystal diffraction (SCD) analysis has the intrinsic limitation that the target molecules must be obtained as single crystals. Here we report a protocol for SCD analysis that does not require the crystallization of the sample. In our method, tiny crystals of porous complexes are soaked in a solution of the target, such that the complexes can absorb the target molecules. Crystallographic analysis clearly determines the absorbed guest structures along with the host frameworks. Because the SCD analysis is carried out on only one tiny crystal of the complex, the required sample mass is of the nanogram–microgram order. We demonstrate that as little as about 80 nanograms of a sample …

Analytical chemistryCrystallography X-RayMass spectrometryHigh-performance liquid chromatographyAbsorptionlaw.inventionCrystallawAnimalsNanotechnologyMoleculeCrystallizationta116Biological ProductsMultidisciplinaryChemistryMicrochemistryAnalytic Sample Preparation MethodsPoriferaCharacterization (materials science)AlkynesFatty AlcoholsAbsorption (chemistry)CrystallizationPorous mediumPorosityNature
researchProduct

Stimulated Raman and Cars Spectroscopy of ν1 and 2ν2 (A1) Bands of 12CF4

1994

Two experimental coherent Raman techniques, stimulated Raman and coherent anti-Stokes Raman spectroscopy (CARS), were employed to study the Raman spectrum of CF 4 in the 900 cm −1 region. The stimulated Raman and CARS spectra of the ν 1 band of CF 4 were recorded at high resolution. The analysis of these spectra enabled some spectroscopic constants of this band to be refined and higher order constants to be determined for the first time. The first high-resolution CARS spectrum of the 2ν 2 (A 1 ) harmonic band is also presented. The rotational transitions of this band up to J = 40 were assigned and the first set of spectroscopic constants for this sub-level were determined. These results imp…

Analytical chemistryHigh resolutionCF4 LASER02 engineering and technology01 natural sciencesQ-BRANCHSpectral lineREGIONABSORPTION-SPECTROSCOPYsymbols.namesake0103 physical sciencesVibrational bandsSPECTRAGeneral Materials ScienceStimulated ramanCoherent anti-Stokes Raman spectroscopyStimulated emissionPOTENTIAL FUNCTIONRADIOFREQUENCY DOUBLE-RESONANCESpectroscopySpectroscopy010304 chemical physicsMOLECULAR LASERSChemistry021001 nanoscience & nanotechnologyRESOLUTION INFRARED-SPECTROSCOPYsymbols0210 nano-technologyRaman spectroscopyDOUBLE-RESONANCE SPECTROSCOPY
researchProduct

Nitroanilines as Quenchers of Pyrene Fluorescence

2012

The quenching of pyrene and 1‐methylpyrene fluorescence by nitroanilines (NAs), such as 2‐, 3‐, and 4‐nitroaniline (2‐NA, 3‐NA, and 4‐NA, respectively), 4‐methyl‐3‐nitroaniline (4‐M‐3‐NA), 2‐methyl‐4‐nitroaniline (2‐M‐4‐NA), and 4‐methyl‐3,5‐dinitroaniline (4‐M‐3,5‐DNA), are studied in toluene and 1,4‐dioxane. Steady‐state fluorescence data show the higher efficiency of the 4‐NAs as quenchers and fit with a sphere‐of‐action model. This suggests a 4‐NA tendency of being in close proximity to the fluorophore, which could be connected with their high polarity/hyperpolarizability. In addition, emission and excitation spectra evidence the formation of emissive pyrene—NA ground‐state complexes in…

Analytical chemistryHyperpolarizabilityPhotochemistryFluorescenceFluorescence spectroscopyAbsorptionDioxaneschemistry.chemical_compoundFOTOQUIMICAANILINASUltrafast laser spectroscopySinglet statePhysical and Theoretical ChemistryFluorescent DyesAniline CompoundsPyrenesQuenching (fluorescence)ChemistryOtras Ciencias QuímicasCiencias QuímicasFluorescenceAtomic and Molecular Physics and OpticsPIRENODESACTIVACIONEnergy TransferExcited statePyreneCIENCIAS NATURALES Y EXACTASTolueneChemPhysChem
researchProduct

Optimization of selenium determination in human milk and whole blood by flow injection hydride atomic absorption spectrometry.

1998

abstract A flow injection hydride atomic absorption spectrometry (FI-HAAS) method was developed for determining selenium in human milk and whole blood after microwave digestion of the sample. The sample (2 mL human milk or 0.25 mL blood) was introduced into the microwave vessel with 1.5 mL HN03 and 0.25 mL H202 and 300 W (4 min) and 600 W (4 min) were applied. The digestion was completed by heating to 140 C (2-3 h). Se (VI) was reduced to Se (IV) with hydrochloric acid. The instrumental conditions for FI-HAAS (concentrations of reducing agent and carrier acid, flow rate of argon carrier gas, and sample volume injected) were optimized. The detection limit of the proposed method was 0.23 ng/m…

Analytical chemistrychemistry.chemical_elementHydrochloric acidAnalytical Chemistrylaw.inventionchemistry.chemical_compoundSeleniumlawPregnancyEnvironmental ChemistryHumansMicrowave digestionWhole bloodPharmacologyDetection limitFlow injection analysisChromatographyMilk HumanSpectrophotometry AtomicchemistryFlow Injection AnalysisFemaleIndicators and ReagentsAtomic absorption spectroscopyAgronomy and Crop ScienceQuantitative analysis (chemistry)SeleniumFood ScienceJournal of AOAC International
researchProduct