Search results for "Analyser"
showing 10 items of 27 documents
FAME: Software for analysing rock microstructures
2016
Determination of rock microstructures leads to a better understanding of the formation and deformation of polycrystalline solids. Here, we present FAME (Fabric Analyser based Microstructure Evaluation), an easy-to-use MATLAB®-based software for processing datasets recorded by an automated fabric analyser microscope. FAME is provided as a MATLAB®-independent Windows® executable with an intuitive graphical user interface. Raw data from the fabric analyser microscope can be automatically loaded, filtered and cropped before analysis. Accurate and efficient rock microstructure analysis is based on an advanced user-controlled grain labelling algorithm. The preview and testing environments simplif…
Measurement of Fractional Exhaled Nitric Oxide: Comparison of Three Different Analysers
2019
<b><i>Background:</i></b> Fractional exhaled nitric oxide (FeNO) is a surrogate marker for airway inflammation, supporting the diagnostic pathway and treatment decisions for asthma patients. <b><i>Objectives:</i></b> Aim of this study was to compare the new analyser Vivatmo pro (Bosch, BV) with NIOX VERO (Circassia, CN) and CLD (Ecomedics, EC). <b><i>Methods:</i></b> In 100 asthmatics (median 53 years [range 20–87], 62% female, 86% on inhaled corticosteroids [mean 1,300 μg beclomethasone dipropionate or equivalent], 35% treated with biologics) 2 FeNO measurements per device were performed. Additionally, the success rate…
Nanoelectron spectroscopy for chemical analysis: a novel energy filter for imaging x-ray photoemission spectroscopy
2005
An ovel instrument for imaging ESCA is described. It is based on a tandem arrangement of two hemispherical energy analysers used as an imaging energy filter. The main spherical aberration (α 2 -term) of the analyser is corrected by the antisymmetry of the tandem configuration. The kinetic energy range useable for imaging extends up to 1.6 keV; this is compatible with Mg and Al Kα laboratory x-ray sources. First experiments on the chemical surface composition of a Cu0.98Bi0.02 polycrystal, a GaAs/AlGaAs heterostructure and Ag crystallites on Si(111) have been performed using synchrotron radiation. The results reveal an energy resolutio no f190 meV and a lateral resolution (edge resolution) o…
Assessment of haemoglobin measurement by several methods - blood gas analyser, capillary and venous HemoCue® , non-invasive spectrophotometry and lab…
2018
A laboratory haematology analyser is the gold standard for measuring haemoglobin concentration but has disadvantages, especially in neonates. This study compared alternative blood-sparing and non-invasive methods of haemoglobin concentration measurement with the gold standard. Haemoglobin concentrations were measured using a laboratory haematology analyser (reference method), blood gas analyser, HemoCue® using venous and capillary blood samples and a newly developed non-invasive sensor for neonates < 3 kg. A total of 63 measurements were performed. Body weight (2190 (1820-2520 [967-4450]) g) and haemoglobin concentration (12.3 (10.6-15.2 [8.2-20.5]) g.dl-1 ) varied widely. Bias/limits of ag…
P-T path development derived from shearband boudin microstructure
2016
This work focuses on the development of a regional P-T-path from the Malpica-Lamego Ductile Shear Zone, NW Portugal, based on the microstructures of shearband boudins evolved during progressive simple shear. The combination of microstructural analysis, fluid inclusion studies, crystallographic pre- ffered orientation and fractal geometry analyses, allows to link several stages in the internal evolution of the boudin to regional P-T conditions. The boudinage process is initiated under differential stress after the original layer achieved sufficient viscosity contrast relative to the surrounding matrix. Two main transformations occur simultaneously: i) change in the external shape with contin…
Analyser of chromium and/or cobalt
2003
Abstract Two stopped-flow manifolds have been proposed for individual or simultaneous determination of chromium and cobalt in water samples. Automated procedures based on multicommutation systems have emphasised the differences of their catalytic effect in luminol–hydrogen peroxide chemiluminescence reaction. A more rapid decay of signal was observed for Co for both configurations (flow injection or continuous injection). The influence of chemical and hydrodynamic variables has been studied in order to establish the robustness of method. The analysis rate was lower 1.5 min per replicate. Chemometric tools have been employed for the resolution of their contributions. Partial least squares (P…
Non-chromatographic speciation of mercury in mushrooms
2016
A fast, sensitive and cheap procedure has been developed for the determination of inorganic mercury (i-Hg) and organic mercury (o-Hg) in mushroom samples. The procedure is based on the use of cold vapour atomic fluorescence spectrometry (CV-AFS). The method involves the extraction of total mercury (t-Hg) with diluted HCl, followed by measurements of the corresponding Hg vapour under two different conditions: (i) directly to determine i-Hg, and (ii) after oxidation with a mixture KBr/KBrO3 to determine t-Hg. o-Hg was estimated from the difference between t-Hg and i-Hg. Previous studies were focused on the assessment of different reagents for mercury extraction and breakdown of organomercury …
Numerical approximation of mixed models for digital integrated circuits
1991
To analyse an electrical network many CAD (Computer Aided Design) circuit simulators are available today. The most well-known is probably SPICE -Nagel [1975]. Although this type of simulator is able to precisely compute the transient performances (as delay time), the usage of complete models of devices implies an extremely high time consumption. So, the circuit simulators are unappropriate for the initial stage of VLSI design where a high speed timing analyser (“timing simulator”) is required. To this goal, alternative approaches using either simpler device models or simpler numerical algorithms or easily computable formulae for delay time approximation, have been developed in the past deca…
Fractionation of mercury in sediments during draining of Augusta (Italy) coastal area by modified Tessier method
2013
Abstract A modified Tessier method was applied to sediments dredged from Augusta (Italy) coastal area with the purpose of establishing the amount and the forms in which mercury is present in the different sediment fractions. The mercury fractionation was made by measuring the concentration of the metal ion on the solutions and directly on the sediment fractions obtained by sequential extraction. The measurements on the solutions as well as that on the solid fractions were carried out by using a Direct Mercury Analyser, DMA 80. This new instrument does not require sample preparation, and gives results comparable to those obtained with CV-AAS and ICP-MS and few minutes are necessary for each …
A new method to measure the size distribution of insoluble submicron particles in water
1994
Abstract In the atmosphere, cloud and fog droplets usually contain insoluble material. The role of these insoluble particles is still unknown today, and is of interest to study. To determine the size distribution and number concentration of these particles in water, different techniques are available. The instrumentation, however, to measure nanometer-sized particles down to 50 nm diameter is not known. A new instrument, the Liquid Tandem Differential Mobility Analyser (LTDMA), was developed to measure size distributions of insoluble particles in water in the size range 50–300 nm in diameter. The new method is based on nebulising, e.g. cloud water and forming a residue aerosol consisting of…