Search results for "Analyte"
showing 10 items of 303 documents
Strategies for the enantiomeric determination of amphetamine and related compounds by liquid chromatography.
2002
This paper summarizes recent research on the stereospecific analysis of amphetamine, its analogs and metabolites, by liquid chromatography. The different methods proposed have been evaluated and compared in terms of resolution power, time of analysis, sensitivity, or potential for automation. Chiral derivatization, followed by separation of the diastereomers formed in achiral chromatographic systems, is still the method preferred for the analysis of amphetamines at trace levels, as derivatization also improves analyte detectability. This is the method of choice for the enantiomeric analysis of amphetamines at the low concentrations typically encountered in biological samples. In recent year…
Speichel als Matrix für das Humanbiomonitoring in der Arbeits- und Umweltmedizin [Biomonitoring Methods in German Language, 2015]
2016
Saliva as a matrix for human biomonitoring in occupational and environmental medicine Purpose: Human biomonitoring (HBM) implies the assessment of internal exposure to hazardous substances by measuring the substances, their metabolites or reaction products, as well as effect parameters in human body fluids. Along with blood, plasma and urine, saliva is of increasing interest as an alternative matrix for HBM. Methods: This paper reviews studies that measure salivary background levels of hazardous substances, elevated levels after environmental or occupational exposure, as well as references which deal with physiological and toxicokinetic behaviour of saliva and salivary parameters, respectiv…
Assessment of oxidative damage to proteins and DNA in urine of newborn infants by a validated UPLC-MS/MS approach
2014
The assessment of oxidative stress is highly relevant in clinical Perinatology as it is associated to adverse outcomes in newborn infants. This study summarizes results from the validation of an Ultra Performance Liquid Chromatography-tandem Mass Spectrometry (UPLC-MS/MS) method for the simultaneous quantification of the urinary concentrations of a set of endogenous biomarkers, capable to provide a valid snapshot of the oxidative stress status applicable in human clinical trials, especially in the field of Perinatology. The set of analytes included are phenylalanine (Phe), para-tyrosine (p-Tyr), ortho-tyrosine (o-Tyr), meta-tyrosine (m-Tyr), 3-NO2-tyrosine (3NO(2)-Tyr), 3-Cl-tyrosine (3Cl-T…
Prediction of the chemiluminescent behavior of pharmaceuticals and pesticides.
2001
The present paper deals with the first attempt to apply molecular connectivity calculations to predict a chemical property with analytical usefulness: the chemiluminescent behavior of substances when reacted with common oxidants in a liquid phase. Preliminary evidence when searching for new direct CL methods consisted of the examination of analyte reaction with a wide range of oxidants and media. This task, which results in time-consuming and trial-and-error expensive procedures, is necessary due to ensure empirical or theoretical rules for CL prediction are available. On the other hand, in quantitative structure-activity relationship studies, molecular connectivity is a topological method …
SIGNAL PROCESSING ALGORITHM FOR SCHLIEREN EFFECT CORRECTION IN FLOW ANALYSIS
2001
Due to the radial refractive index gradients that sometimes develop in flow cells during the travelling of the samples through them, the absorbance records obtained in such conditions have a strange shape, particularly at low analyte levels. To correct this phenomenon, called Schlieren effect, a simple and reliable signal processing algorithm is described in correlation to the detector characteristics of noise. The algorithm is illustrated in nitrite and nitrate determinations with proflavin from more real samples. It has a solid theoretical support and involves the subtraction from the sample records of a smoothed signal, acquired by working with a blank solution.
More about sampling and estimation of mercaptans in air samples
2013
[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…
Comparison of silica-based materials for organophosphorus pesticides sampling and occupational risk assessment.
2020
Abstract A novel air sampler has been designed containing a sorbent based on UVM-7 mesoporous silica doped with Ti. The sorbent has been applied for the determination of organophosphorus pesticides in occupational air, followed by gas chromatography with mass spectrometry detection. Thus, several silica materials with different structures (mesoporous UVM-7 and microporous xerogels) were synthesized, and modified with the addition of Ti and Fe. The structure of these materials was proved by transmission electronic microscopy, energy-dispersive X-ray, X-ray diffraction, nitrogen adsorption-desorption and UV–Vis and Raman spectroscopy. The potential of these materials for the retention of pest…
Development of a selective solid phase extraction method for nitro musk compounds in environmental waters using a molecularly imprinted sorbent
2013
A powerful analytical method for the determination of the family of the nitro musk compounds at trace level in environmental waters-river, sea, and water from a treatment plant-is presented. The method is based on the use of molecularly imprinted silica (MIS) as sorbent for solid phase extraction (SPE) used for the clean-up and the concentration step of the target analytes previous to their determination by gas chromatography-mass spectrometry. The optimized extraction procedure allowed extraction recoveries between 61% and 87% using the MIS. The comparison with a non-imprinted silica (NIS) sorbent, for which extraction recoveries between 8% and 26% were obtained, showed the high selectivit…
A solid colorimetric sensor for the analysis of amphetamine-like street samples.
2016
A solid sensor obtained by embedding 1,2-naphthoquinone-4-sulfonate (NQS) into polydimethylsiloxane/tetraethylortosilicate/silicon dioxide nanoparticles composite has been developed to identify and determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxymetamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA). The analytes are derivatized inside the composite for 10 min to create a colored product which can be then quantified by measuring the diffuse reflectance or the color intensity after processing the digitalized image. Satisfactory limits of detection (0.002–0.005 g mL−1) and relative standard deviations (<10%) have been achieved. The proposed kit has been successfu…
Tips on ligand immobilization and kinetic study using surface plasmon resonance.
2016
Surface plasmon resonance (SPR) technique offers a robust label-free approach applicable in various investigations including binding affinity, specificity and kinetics of biological macromolecules (e.g., peptides, proteins and nucleotidase) and small molecules. SPR provides extremely important data on the kinetics and affinity of substances examined, through which bio-specific interaction(s) can be established by the analysis of adsorption of analyte onto the immobilized ligand(s) on a sensor-based analytical system. Due to SPR wide applications in biomedical laboratories, the aim of this editorial is to highlight the importance of SPR in affinity kinetics and ligand immobilization.