Search results for "Analyte"

showing 10 items of 303 documents

Towards comprehensive non-target screening using heart-cut two-dimensional liquid chromatography for the analysis of organic atmospheric tracers in i…

2021

Abstract Non-target screening of secondary organic aerosol compounds in ice cores is used to reconstruct atmospheric conditions and sources and is a valuable tool to elucidate the chemical profiles of samples with the aim to obtain as much information as possible from one mass spectrometric measurement. The coupling of mass spectrometry to chromatography limits the results of a non-target screening to signals of compounds within a certain polarity range based on the utilized stationary phases of the columns. Comprehensive two-dimensional liquid chromatography (LCxLC) introduces a second column of different functionality to enable the analysis of a broader range of analytes. Conventional LCx…

AerosolsDetection limitChromatography Reverse-PhaseAnalyteChromatographyChemistryHydrophilic interaction chromatographyOrganic ChemistryGeneral MedicineRepeatabilityMass spectrometrySnowBiochemistryMass SpectrometryAnalytical ChemistryAerosolVolume (thermodynamics)Hydrophobic and Hydrophilic InteractionsChromatography LiquidJournal of Chromatography A
researchProduct

Bimodal porous silica nanomaterials as sorbents for an efficient and inexpensive determination of aflatoxin M1 in milk and dairy products

2020

Abstract An extraction procedure was developed for the determination of aflatoxin M1 in milk and dairy products. A sorbent based on UVM-7 mesoporous silica was used as solid phase for the sample clean-up, and the analyte determination was carried out by HPLC coupled to a fluorescence detector. The material architecture was characterized by transmission electronic microscopy, X-ray diffraction, 29Si NMR and nitrogen adsorption-desorption. After the optimization of extraction parameters, the influence of the matrix has been evaluated, obtaining recoveries in the range 78–105% for whole and skimmed milk and yogurt matrix. The reusability of the material was also proved. The sensitivity of the …

AflatoxinAnalytefood.ingredientSorbentChromatographyMaterials science010401 analytical chemistryExtraction (chemistry)04 agricultural and veterinary sciencesGeneral MedicineMesoporous silica040401 food science01 natural sciences0104 chemical sciencesAnalytical ChemistryMatrix (chemical analysis)0404 agricultural biotechnologyfoodSkimmed milkSolid phase extractionFood ScienceFood Chemistry
researchProduct

The generalized H-point standard-additions method to determine analytes present in two different chemical forms in unknown matrix samples. Part II. C…

2000

The generalized H-point standard-additions method (GHPSAM) is used in order to obtain the total Cr(VI) and chromate concentration in water samples whose matrices are completely unknown. Moreover, a new methodology, which is a modification of the GHPSAM, is proposed for the simultaneous determination of the two major chemical forms of Cr(VI) present in the sample. The method is based on the location of spectral intervals where the behaviour of the interferent absorbance can be considered as linear. From these intervals, the analyte concentration free from bias error can be estimated. Spiked samples of dig and harbour water measured in the UV–visible spectral region have been tested to check …

AnalyteAbsorption spectroscopyChromate conversion coatingChemistryAnalytical chemistryBiochemistryAnalytical ChemistryChemometricsAbsorbanceMatrix (mathematics)Standard additionElectrochemistryEnvironmental ChemistryQuantitative analysis (chemistry)SpectroscopyThe Analyst
researchProduct

Apparent content curves: description and analytical applications. Resolution of binary mixtures

1992

The apparent content curves and their analytical applications are described. Basing on these curves a mathematical method, which permits the identification of the interfering component present in a binary mixture as well as the determination of the contents of both constituents, is proposed. The existence of considerable interaction coefficients is not an impediment for its application. Besides, the analyte contents in the mixture can be obtained without the use of standard interference solutions. The proposed procedure is applied to the analysis of mixtures of dyes with overlapping absorption spectra.

AnalyteAbsorption spectroscopyResolution (mass spectrometry)ChemistryComponent (thermodynamics)Content (measure theory)Analytical chemistryBinary numberInterference (wave propagation)Biological systemBiochemistryAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Development of immunoaffinity columns for pyraclostrobin extraction from fruit juices and analysis by liquid chromatography with UV detection

2010

Abstract Pyraclostrobin belongs to a new generation of fungicides widely used to preserve high valuable crops. In the present study, three monoclonal antibodies with different affinities to this modern strobilurin have been evaluated for their usefulness in the production of immunoaffinity columns suitable for the solid-phase extraction, concentration, and clean-up of residues from food commodities. Different immunosorbents were produced and characterized in terms of antibody immobilization efficiency, immunosorbent binding capacity, optimum elution conditions, and reusability. Covalent coupling of the antibodies to Sepharose–CNBr gel took place with high yield (over 90%), whereas the immun…

AnalyteAcetonitrilesSensitivity and SpecificityBiochemistryChromatography AffinityAnalytical ChemistryBeveragesSepharoseEquipment ReuseVitisImmunosorbent TechniquesDetection limitChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Pesticide ResiduesAntibodies MonoclonalGeneral MedicineImmunosorbentsStrobilurinsFungicides IndustrialFruitMalusStrobilurinPyrazolesSpectrophotometry UltravioletCarbamatesHaptenJournal of Chromatography A
researchProduct

High-pressure flow-injection assembly. Indirect determination of glycine by atomic absorption spectrometry.

1991

A procedure for the determination of glycine is described. The method is based on the reaction of the analyte with finely powdered, solid copper(II) carbonate in a continuous-flow assembly. The optimum experimental conditions of pH, temperature, sample volume, flow-rate, column length and internal diameter, and the linear range of calibration, were studied. Interference from foreign substances that accompany this amino acid in pharmaceutical formulations was studied, and the method was applied to the determination of glycine.

AnalyteAnalytical chemistryGlycinechemistry.chemical_elementBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundlawElectrochemistryCalibrationEnvironmental ChemistrySpectroscopychemistry.chemical_classificationChromatographyChemistrySpectrophotometry AtomicTemperatureHydrogen-Ion ConcentrationCopperAmino acidLinear rangeGlycineCarbonic AcidCarbonateIndicators and ReagentsAtomic absorption spectroscopyThe Analyst
researchProduct

Selective determination of trimethylamine in air by liquid chromatography using solid phase extraction cartridges for sampling.

2004

Abstract The selective determination of trimethylamine (TMA) in air by liquid chromatography is reported. Sampling is effected by flushing air through C18-packed solid-phase extraction (SPE) cartridges at a flow rate of 15 mL/min for 15 min. Next, TMA is desorbed from the cartridges and injected into the chromatographic system. The analyte is then selectively retained on a precolumn ( 20 mm ×2.1 mm i.d., packed with 30 μm, Hypersil C18 phase), and derivatized on-line by injecting 9-fluorenylmethyl chloroformate (FMOC). Finally, the TMA-FMOC derivative is transferred to the analytical column ( 125 mm ×4 mm i.d., LiChrospher 100 RP18, 5 μm), and monitored at 262 nm. The method was applied to …

AnalyteAnalytical chemistryTrimethylamineChloroformateAir Pollutants OccupationalBuffersBiochemistryAnalytical ChemistryCartridgechemistry.chemical_compoundMethylaminesBoric AcidsSolid phase extractionDetection limitReproducibilityChromatographyOrganic ChemistryExtraction (chemistry)Reproducibility of ResultsGeneral MedicineReference StandardsSolutionschemistryCalibrationIndicators and ReagentsSpectrophotometry UltravioletChromatography Liquid
researchProduct

Mepanipyrim haptens and antibodies with nanomolar affinity

2013

Mepanipyrim is an anilinopyrimidine fungicide used worldwide for crop protection. With the aim of developing useful immunoreagents for mepanipyrim immunoanalysis, two new functionalized derivatives were prepared and antibodies were generated. Affinity and specificity were assessed by direct and indirect competitive ELISA using homologous and heterologous conjugates. Although all antibodies were selective for the target analyte, the immunizing hapten structure was revealed as a determinant for high-affinity antibody production (IC50 = 3 nM). © 2013 The Royal Society of Chemistry.

AnalyteAntibody AffinityHeterologousBiochemistryAntibodiesAnalytical ChemistryElectrochemistryAnimalsEnvironmental ChemistryMepanipyrimIC50SpectroscopyA determinantImmunoassayChromatographybiologyChemistryAntibody productionPyrimidinesBiochemistrybiology.proteinFemaleRabbitsAntibodyHaptensHaptenConjugateThe Analyst
researchProduct

Determination of antimony, arsenic, bismuth and copper by inductively coupled plasma atomic emission spectrometry in the electrorefining of copper

1996

Inductively coupled plasma atomic emissionspectrometry (ICP-AES) has been applied as a rapid and routine method for the analysis of process electrolytes in the electrorefining of copper. Antimony, arsenic, bismuth and copper have been selected as major electrolyte constituents. For these elements profound statistical studies of spectral and interelement effects have been carried out. For As, Bi and Sb two analyte wavelengths have been selected, and for Cu one relatively insensitive analyte line has been chosen due to the high Cu concentration in samples. Best analytical lines were: As at 193.759 nm, Bi at 306.772 nm, Sb at 206.833 nm and Cu at 216.953 nm. Multiple linear regression proved t…

AnalyteAntimonyChemistryAnalytical chemistrychemistry.chemical_elementElectrolyteInductively coupled plasmaBiochemistryCopperArsenicAnalytical ChemistryElectrowinningBismuthAnalytical and Bioanalytical Chemistry
researchProduct

Fully Automated Electric-Field-Driven Liquid Phase Microextraction System with Renewable Organic Membrane As a Front End to High Performance Liquid C…

2019

This article reports for the first time a programmable-flow-based mesofluidic platform that accommodates electric-field-driven liquid phase microextraction (μ-EME) in a fully automated mode. The miniaturized system is composed of a computer-controlled microsyringe pump and a multiposition rotary valve for handling aqueous and organic solutions at a low microliter volume and acts as a front-end to online liquid chromatographic separation. The organic membrane is automatically renewed and disposed of in every analytical cycle, thus minimizing analyte carry-over effects while avoiding analyst intervention. The proof-of-concept applicability of the automated mesofluidic device is demonstrated b…

AnalyteAqueous solutionChromatographyChemistry010401 analytical chemistryExtraction (chemistry)Repeatability010402 general chemistry01 natural sciencesHigh-performance liquid chromatography0104 chemical sciencesAnalytical ChemistryMembraneVolume (thermodynamics)Electric fieldAnalytical Chemistry
researchProduct