Search results for "Analyte"
showing 10 items of 303 documents
Direct ELISA kits as a sensitive and selective screening method for abstinence control in urine.
2011
In 2009 cutoff values of assessment criteria to testify abstinence control in order to estimate driving ability were standardized in Germany. The cutoff values are lower than required in existing guidelines like SAMHSA and there is critical discussion about detection of low concentrations by using immunoassay, especially concerning amphetamines in urine (50 ng/ml). In this study Direct ELISA kits were tested for their applicability to identify the absence of amphetamines, cannabinoids, opiates, cocaine, methadone and benzodiazepines in urine. Results were confirmed by LC/MS or GC/MS analyses. Sensitivity, specificity, predictive values (positive as well as negative) and overall misclassific…
Highly sensitive monoclonal antibody-based immunoassays for boscalid analysis in strawberries
2018
Boscalid is an agrochemical recently developed for crop protection and the most significant member of the succinate dehydrogenase inhibitor group of fungicides. In this study, a collection of high-affinity monoclonal antibodies was generated to boscalid. By using a series of haptens with a linker at alternative tethering sites of the boscalid framework, specific antibodies were isolated as well as antibodies that also recognized the main boscalid metabolite. Two immunoassays were developed using different ELISA formats. Optimized assays displayed very high sensitivities (limits of detection were near 0.01 µg/L). Trueness and precision for the determination of the target analyte in strawberr…
Pyrene-functionalized nanoparticles: two independent sensors, the excimer and the monomer.
2012
The high surface-to-volume ratio of nanoparticles has been used to obtain a high local concentration of pyrene units on their periphery, making the formation of both pyrene emissive species possible using amazingly small pyrene concentrations. The sensing properties of model pyrene-functionalized nanoparticles was investigated by using different nitroaromatic compounds [m-nitroaniline and p-nitroaniline] and nitrobenzenes [nitrobenzene, p-nitrotoluene, 2,4-dinitrotoluene, and 2,6-dinitrotoluene]. The hybrid system acts as a dual-fluorescence sensor, in which the decrease of the pyrene emission, induced by the quencher, is hardly reflected in the pyrene excimer emission. The encapsulation ca…
Novel haptens and monoclonal antibodies with subnanomolar affinity for a classical analytical target, ochratoxin A
2018
Ochratoxin A is a potent toxic fungal metabolite whose undesirable presence in food commodities constitutes a problem of public health, so it is strictly regulated and controlled. For the first time, two derivatives of ochratoxin A (OTAb and OTAd) functionalized through positions other than the native carboxyl group of the mycotoxin, have been synthesized in order to better mimic, during the immunization process, the steric and conformational properties of the target analyte. Additionally, two conventional haptens making use of that native carboxyl group for protein coupling (OTAe and OTAf) were also prepared as controls for the purpose of comparison. The immunological performance in rabbit…
Direct Analysis of Psilocin and Muscimol in Urine Samples Using Single Drop Microextraction Technique In-Line with Capillary Electrophoresis
2020
The fully automated system of single drop microextraction coupled with capillary electrophoresis (SDME-CE) was developed for in-line preconcentration and determination of muscimol (MUS) and psilocin (PSC) from urine samples. Those two analytes are characteristic active metabolites of Amanita and Psilocybe mushrooms, evoking visual and auditory hallucinations. Study analytes were selectively extracted from the donor phase (urine samples, pH 4) into the organic phase (a drop of octanol layer), and re-extracted to the acidic acceptor (background electrolyte, BGE), consisting of 25 mM phosphate buffer (pH 3). The optimized conditions for the extraction procedure of a 200 µ
Quantification of rifampicin and rifabutin in plasma of tuberculosis patients by micellar liquid chromatography
2020
A Micellar Liquid Chromatographic method is described to determine Rifampicin and Rifabutin in plasma from Tuberculosis patients. Samples were diluted in mobile phase and then directly injected, avoiding long and tedious extraction steps. The analytes were resolved from the matrix without interferences from endogenous compounds using a mobile phase of sodium dodecyl sulfate 0.15 mol L-1–6%(v/v) 1-pentanol and phosphate buffer at pH 3, running at 1 mL min−1 through a C18 column at 25 °C. Detection was carried out by UV absorbance at 270 nm. Under these conditions, the final chromatographic analysis time was 22 min. The analytical methodology was validated following the FDA 2018 Bioanalytical…
Procedures for Antibiotic Residues in Bovine Muscle Tissues
2011
Abstract Acetonitrile extraction followed by primary-secondary amine dispersive SPE cleanup QuEChERS (quick, easy, cheap, effective, rugged, and safe), was compared to pressurized liquid extraction (PLE) using water at 70°C for 10 min at 1500 psi for the determination of 16 veterinary drugs in bovine muscle tissues by LC/MS/MS. PLE was significantly more effective for the extraction of veterinary drugs (ranging from 69 to 103% with RSD ≤ 18%) than QuEChERS (ranging from 19 to 89% with RSD ≤ 19%). Linearity of the calibration curves was obtained over the range considered (from 10 μg/kg or LOQ to 1000, μg/kg) with r2 ≥ 0.99 for all the analytes by both methods. Although an internal standard w…
Determination of trimethylamine-N-oxide in combination withl-carnitine andγ-butyrobetaine in human plasma by UPLC/MS/MS
2015
An ultra-high-performance liquid chromatography-mass spectrometry (UPLC/MS/MS) method was developed and validated for the quantification of trimethylamine-N-oxide (TMAO) simultaneously with TMAO-related molecules L-carnitine and γ-butyrobetaine (GBB) in human blood plasma. The separation of analytes was achieved using a Hydrophilic interaction liquid chromatography (HILIC)-type column with ammonium acetate-acetonitrile as the mobile phase. TMAO determination was validated according to valid US Food and Drug Administration guidelines. The developed method was successfully applied to plasma samples from healthy volunteers.
Analytical utility of quadrupole time-of-flight mass spectrometry for the determination of pesticide residues in comparison with an optimized column …
2009
Abstract A multiresidue method for the analysis of 30 pesticides with different physicochemical properties in fruits and vegetables was developed. The method involves a rapid and small-scale extraction procedure based on matrix solid-phase dispersion using octadecylsilyl (C18) as the dispersant and dichloromethane as the eluent. The target pesticides were determined using column high-performance liquid chromatography/triple quadrupole-tandem mass spectrometry (LC/QqQ-MS/MS). The method was validated for sensitivity, linearity, reproducibility, and accuracy. A recovery study was conducted at 3 different levels, and the average ranged from 74 to 99 for all of the studied compounds, with relat…
Detection and correction of interferences in spectroscopy techniques
2001
By combining the apparent content curves method and the Youden method, we have developed a strategy for detecting constant and proportional errors in spectroscopy techniques. A method for elimination of spectral interferences (different of blank) is also proposed. To apply of this method there must be a matrix effect that varies with the amount of sample or a simulated matrix effect provided working under different experimental conditions that induce a variation of the analytical signal of the analyte. The proposed procedures have been applied to the determination of methyl orange in presence of phenol red, bromothymol blue and bromocresol purple.