Search results for "Analyte"
showing 10 items of 303 documents
Green aspects, developments and perspectives of liquid phase microextraction techniques.
2014
Determination of analytes at trace levels in complex samples (e.g. biological or contaminated water or soils) are often required for the environmental assessment and monitoring as well as for scientific research in the field of environmental pollution. A limited number of analytical techniques are sensitive enough for the direct determination of trace components in samples and, because of that, a preliminary step of the analyte isolation/enrichment prior to analysis is required in many cases. In this work the newest trends and innovations in liquid phase microextraction, like: single-drop microextraction (SDME), hollow fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liqu…
Environmentally friendly LC for the simultaneous determination of ascorbic acid and its derivatives in skin-whitening cosmetics
2008
Ascorbic acid (AA), also known as vitamin C, is a very popular skin-whitening agent used in cosmetics. However, the use of AA (and also its sodium or magnesium salts) in cosmetic products is limited owing to its labile oxidative properties. In order to avoid its early degradation, different derivatives have been designed, such as ascorbyl phosphate (APH; as magnesium or sodium salts) and ascorbyl palmitate (AP), and more recently the ascorbyl glucoside (AG). Bearing in mind that all these chemicals in skin-whitening cosmetic products must be determined in order to control the efficacy of such products, this paper focuses on developing a wide-ranging LC analytical method able to determine th…
Flow-injection spectrofluorimetric determination of paracetamol
1990
Abstract A flow-injection spectrofluorimetric determination of paracetamol is reported, based on the oxidation of the analyte with potassium hexacyanoferrate(III) immobilized on an anion-exchange resin, the fluorescence being enhanced with N,N′-dimethylformamide. Concentrations of paracetamol in the range 0.04–17.60 mg l−1 are determined with a relative standard deviation of 1.5%. The injection rate is 25 samples h−1. The influence of foreign species and the determination of paracetamol in several pharamaceutical formulations are also reported.
Sensitive and selective plasmonic assay for spermine as biomarker in human urine.
2014
A simple, fast, and highly selective and sensitive colorimetric assay to detect nanomolar levels of spermine in human urine (healthy donors, cancer patients) is reported. This assay is based on the absence of a competitive organic capping on the gold nanoparticles together with the high affinity of the amine groups of the analyte for the nanoparticle surface.
A preliminary study on the stability of benzodiazepines in blood and plasma stored at 4 degrees C.
1997
An approach to determine the stability of benzodiazepines and some of their metabolites (n = 13) by means of a routinely applied gas chromatographic method using electron capture detection was made in this preliminary study. Validation data of the method are given. Spiked blood and plasma samples were stored at 4 degrees C and analysed at selected times up to 240 days. The concentrations of all analytes had decreased to at least 60% of the original levels at the end of the observation period. A clear pattern of breakdown could not be established. The data obtained suggest that results from long-term stored samples should be interpreted cautiously. Further investigations concerning the stabi…
Development and validation of a fast and sensitive chromatographic assay for all-trans-retinol and tocopherols in human serum and plasma using liquid…
2002
A sensitive HPLC assay for all-trans-retinol, alpha-tocopherol, and gamma-tocopherols in human serum and plasma is reported. Sample preparation is performed in one step and involves precipitation of proteins and extraction of lipids with two volumes of an ethanol-chloroform mixture (3:1, v/v) without I.S. addition. After removal of the precipitated protein, 20 microl aliquots of the supernatant (equivalent to 6.7 microl of serum or plasma) were injected into the HPLC system and analyzed using fluorometric detection. RP-HPLC was performed using a C(18) S3 ODS2 column with a methanol-water step gradient (97:3 to 100) at 1.0 ml/min. The quantification limit expressed as nanograms of analyte pe…
Determination of tannic acid by direct chemiluminescence in a FIA assembly
2002
The determination of tannic acid is performed in a FIA assembly on the basis of the analytical output obtained by oxidation of the acid. The analyte solution was daily prepared in a mixture of quinine as sensitiser and perchloric acid and it was injected into a pure water stream acting as a carrier. This solution merges with the mixture potassium permanganate in perchloric medium and the resulting chemiluminescence is monitored. The method was applied over the range 0.5-20 mg l(-1) of tannic acid with a LOD 100 mug l(-1). The reproducibility was 2.1% and the sample throughput 54 h(-1). The influence of foreign substances was studied and the new method is applied to the determination of tann…
Determination of aliphatic amines in water by liquid chromatography using solid-phase extraction cartridges for preconcentration and derivatization
2001
Bond Elut C18 solid-phase extraction cartridges were used for preconcentration and pre-column derivatization with 3,5-dinitrobenzoyl chloride (DNB) of aliphatic amines in water. Conditions for analyte preconcentration and derivatization (including the volume of sample, concentration of reagent, time of reaction and pH) were investigated, using ethylamine, isopropylamine and dimethylamine as model compounds. On the basis of these studies, a rapid and sensitive method for the determination of aliphatic amines in water is presented. The analytes are retained and purified on the cartridges and then derivatized and desorbed by drawing in succession the DNB solution and acetonitrile. The collecte…
Analytical potential of mid-infrared detection in capillary electrophoresis and liquid chromatography: a review.
2010
Literature published in the last decade concerning the use of mid-infrared spectrometry as a detection system in separation techniques employing a liquid mobile phase is reviewed. In addition to the continued use of isocratic liquid chromatographic (LC) techniques, advances in chemometric data evaluation techniques now allow the use of gradient techniques on a routine basis, thus significantly broadening the range of possible applications of LC-IR. The general trend towards miniaturized separation systems was also followed for mid-IR detection where two key developments are of special importance. Firstly, concerning on-line detection the advent of micro-fabricated flow-cells with inner volu…
Determination of the Herbicide Fluometuron by Photo‐induced Chemiluminescence in a Continuous‐flow Multicommutation Assembly
2007
Abstract This study was dealing with the chemiluminometric determination of the selective herbicide Fluometuron or 1,1‐dimethyl‐3‐(α,α,α‐trifluoro‐m‐tolyl)urea, (C10H11F3N2O) with a molecular weight 232.29 belongs to the phenyl urea herbicides family. The analytical strategy is based on the continuous‐flow manifold, multicommutation and the analyte pre‐treatment, the photo‐degradation. The optimization of chemical (pH, medium, temperature, and organized media) and hydrodynamic parameters (volume of reagents and flow rate) was performed by univariant and multiparametric simplex procedure respectively. Analytical figures of merit and the effect of foreign substances were studied. The method r…